KITOZER copper clad steel grounding electrode rod is a driven earth rod that combines the high conductivity of copper with the mechanical strength of low carbon steel. The 16mm diameter by 1.5 meter length is the industry standard for building earth electrodes, telecom tower foundations, and small substation grids. A molecular copper layer of 0.25mm thickness is bonded to the steel core under high heat, giving a permanent metallurgical bond that will not peel, blister, or separate during driving. The rod can be driven into hard soil with a standard jack hammer, extended with coupling sockets to reach 6 meters or more, and connected to copper tape using exothermic welds or listed mechanical clamps.
Table of Contents
ToggleProduct Overview
Pure copper rods are soft and bend easily when driven into gravel or rocky soil, while pure steel rods have high corrosion but poor conductivity. KITOZER copper clad steel rod solves both problems: the steel core takes the driving hammer impact and the copper skin provides the low resistance contact with soil. The result is an electrode that can reach deep wet soil layers, withstand repeated driving, and provide a stable earth resistance for decades. KITOZER supplies pointed tips, driving heads, and UL listed coupling sockets so that installers can extend rods vertically in difficult soil without digging deep trenches. The rod is also available as threaded length for coupling, or plain length with exothermic weld cup for tape connection.
Technical Specifications
Core: low carbon steel 4.5 percent C equivalent, tensile strength minimum 410 MPa. Copper layer thickness: 0.25mm standard, 0.10mm economy grade available. Diameters: 14.2mm, 16mm, 17.2mm, 20mm, 25mm. Lengths: 1.2m, 1.5m, 2.4m, 3.0m, 3.6m. Coupling: UL listed bronze threaded socket, extends rod to any depth. DC resistance: equivalent to pure copper of same outer diameter, less than 0.0025 ohm per meter for 16mm rod. Corrosion life: minimum 30 years in soil resistivity 100 ohm m, 50 years in 50 ohm m soil. Standards: IEC 62561 part 2, UL 467, GB 50057, IEEE 80. Driving head: hardened steel cap included. Connection: exothermic weld cup or mechanical clamp for 25x2mm tape or 50mm2 stranded wire. Package: 50 rods per wooden crate, 250kg.
Applications
The 16x1500mm KITOZER rod is driven into the ground at the base of every building down conductor, at telecom tower feet, at street light bases, and at fence corners. In substations multiple rods are driven in a grid around the perimeter and connected by buried copper tape to form a low resistance earth mat. For high soil resistivity sites, rods are coupled together in groups of four to six and deep driven to 6 meters or more to reach permanently moist subsoil. Wind turbine and photovoltaic foundations use the rod as the dedicated electrode for the transformer neutral and lightning protection system. Industrial plants use rods at each pipe entry, instrument junction box, and hazardous area boundary to maintain equipotential bonding.
Advantages
Compared with galvanized steel rod, KITOZER copper clad rod offers ten times longer corrosion life because the copper layer does not rely on sacrificial zinc. Compared with solid copper rod, it is far less expensive and far more resistant to bending during driving. The metallurgical bond prevents the copper layer from peeling back under hammer impact, a common failure with electroplated rods. Coupled multi-rod arrays reach deep moist soil without wide excavation, which is ideal for retrofit in dense urban sites. The rod is approved for hazardous area service because it produces no spark when driven. Test reports on corrosion rate in saline soil are available, making the rod suitable for coastal power plants, offshore substation onshore terminals, and desalination plants.
Installation and Maintenance
Drive the rod vertically using a hardened steel driving head and a 2kg jack hammer. Do not strike the top thread directly. When extending, screw in the bronze coupling socket, apply anti-seize compound, and drive the next length. After the rod reaches final depth, clean the top 100mm of copper skin with a wire brush, then connect to copper tape using KITOZER exothermic weld or listed mechanical clamp. Backfill around the rod with native soil, compact, and water. Measure earth resistance with a fall of potential tester; typical single rod in 100 ohm m soil reads 30 to 50 ohm, and multiple rods in parallel reduce to below 1 ohm. Inspect exposed top clamps every two years, and remeasure earth resistance annually to detect seasonal soil dry-out.
Available Models and Custom Service
KITOZER stocks the 16x1500mm 0.25mm copper clad rod in both threaded and plain top versions for immediate dispatch. Larger diameters including 20mm and 25mm are available for rocky soil, and 3.0m or 3.6m long rods are used where deep driving is required. The threaded version with UL listed bronze couplings allows extension to 6m, 9m, or deeper in high resistivity sites. KITOZER also supplies a 0.10mm copper layer economy grade for budget projects where soil is neutral, and a 0.35mm heavy corrosion grade for coastal and saline soil. Complete electrode kits including driving head, coupling, exothermic weld cup, and molds are quoted on project drawings.
Price
From $35 per rod for 16x1500mm 0.25mm copper clad. Couplings $12 each. Exothermic weld kits quoted on project. Contact +86 13922289957 for bulk electrode pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com