KITOZER Copper Ground Busbar: Tin Plated

Product Overview

The KITOZER tin-plated copper ground busbar provides a low-impedance central grounding point in cabinets, data centers, and industrial control panels. Made from high-conductivity copper with a matte tin plating, the bar offers many pre-punched studs for bonding protective earth, signal reference, and shield ground conductors. A properly installed busbar equalizes potential across the cabinet and gives surge protective devices a short, direct path to earth.

Without a central busbar, grounds scatter across the cabinet on individual wires, creating loops and high-impedance paths. The busbar collects every ground connection at one point, so protective earth, signal reference, and cable shields all meet at the same potential. The tin plating prevents the oxidation that would otherwise raise contact resistance over decades of service.

Technical Specifications

Copper grade C11000, cross section from 20 mm by 3 mm to 100 mm by 10 mm. Tin plating thickness 8 to 12 micron. Number of stud holes from 4 to 40 depending on length. Lengths from 100 mm to 2000 mm. Insulating mounting supports included. Short-time current rating per section area. UL 94V0 insulating supports.

The studs are punched and threaded to accept standard ring terminals, and the insulating standoffs isolate the bar from the cabinet until it is intentionally bonded. The tin plating is matte so it does not develop the high-resistance oxide that bare copper grows in air. The short-time current rating handles fault currents without fusing the bar. For larger cabinets, multiple bars can be mounted in parallel to carry higher fault currents, and the insulating supports keep them isolated from each other until the design bonds them at the busbar end. This modular approach lets the grounding system scale as the cabinet grows.

Applications

Mount vertically or horizontally in MCC cabinets, UPS battery rooms, telecommunications racks, and shielded rooms. Used to bond equipment chassis, cable shields, protective earth conductors, and the earth electrode at a single point to avoid ground loops and provide fault current capacity.

A battery room uses the busbar as the central earth point for the battery cabinet. A telecom rack uses it to bond all cable shields. A shielded room uses it as the single-point ground that bonds the room shield to the building earth. In each case, the busbar is the hub that keeps potentials equal. For data centers, multiple busbars can be tied together with braided straps to form a grounding grid that equalizes potential across the row. The bar also provides a convenient test point for commissioning, because a technician can clip a meter lead to any stud without hunting for a ground in the cabinet.

Advantages and Features

Tin plating prevents oxidation and maintains low contact resistance over decades, unlike bare copper which tarnishes. Pre-punched studs with washers and nuts accept multiple conductor sizes. The insulating standoffs isolate the bar from the cabinet until intentionally bonded, avoiding accidental ground loops. High short-time current rating handles fault currents without fusing.

The bar is stocked in standard lengths and cross sections, so designers do not machine a custom part. The insulating supports also let the bar float until the design calls for a single-point bond, which avoids the loops that accidental contacts would create. The busbar is also available with pre-drilled hole patterns matching common lug sizes, so the installer does not need to tap threads in the field. This reduces installation errors and speeds up cabinet build time.

Installation and Maintenance

Mount on insulating supports and torque studs to the recommended value. Bond the busbar to the cabinet earth with a braided strap for high-frequency continuity. Keep signal ground and power ground bonded at a single point. Inspect torque annually and clean oxide with a contact file if needed.

During commissioning, measure the resistance from each stud to the earth electrode and record the readings. Re-torque studs after the first year because copper creep can loosen connections. In dusty or corrosive cabinets, inspect the tin surface annually and re-tin if the plating shows wear. For new installations, the busbar is supplied with a test certificate showing the resistance per stud, which gives the commissioning team a baseline to compare against for years of service. This baseline is valuable for troubleshooting intermittent ground-related faults.

Price

From $12 per bar. Contact plus 86 13922289957 for custom lengths and hole patterns.