KITOZER copper grounding tape is a flat rolled copper strip used as a flexible down conductor, horizontal earth loop, and equipotential bonding jumper in lightning protection and earthing systems. The 25x2mm size is the most popular cross section specified for building lightning down conductors and for buried earth grids around substations. Manufactured from T2 electrolytic copper with 99.9 percent purity, KITOZER tape can be bent by hand around wall corners, roof edges, and cable tray bends without cracking, which makes installation much faster than rigid round copper bar. The tape is supplied in coils of 30 meters or 50 meters to reduce joints in long runs, and can be cut and joined with exothermic welds, mechanical clamps, or silver soldering depending on site practice.
Table of Contents
ToggleProduct Overview
KITOZER flat copper tape is preferred over round conductor for lightning protection because its wide cross section has lower inductance per unit length, which is critical for fast front lightning impulse currents. A flat tape also lies flush against masonry or cable tray, reducing visual impact and avoiding the snag risk of round bar. For buried earth grids, the flat tape offers larger contact area with surrounding soil, improving current dissipation into the earth. KITOZER supplies bare tape for indoor and buried use, and PVC-sheathed tape for corrosive soil or direct burial where stray current protection is required. Pre-punched connection holes can be provided at both ends of each coil for quick clamp fitting.
Technical Specifications
Material: T2 electrolytic copper, 99.9 percent Cu. Standard sections: 12x2mm, 15x2mm, 20x2mm, 25x2mm, 25x3mm, 30x3mm, 40x4mm. Coil length: 30m or 50m standard, custom spools available. DC resistance: maximum 0.036 ohm per meter for 25x2mm at 20 degrees Celsius. Impulse current rating: 100 kA 10 by 350 microsecond waveform per IEC 62305 for 25x2mm tape. Tensile strength: minimum 200 N per mm2. Minimum bending radius: 2.5 times tape width without annealing. Surface: bare mill finish, or 8 micron hot tinning option, or black PVC sheath 1mm wall. Standards: IEC 62561 part 2, IEC 62305, GB 50057. Operating temperature: minus 40 to plus 105 degrees Celsius. Package: wooden coil crate, 200kg per pallet.
Applications
The 25x2mm KITOZER copper tape is used as lightning down conductor on industrial buildings, steel structures, telecom towers, wind turbines, and rooftop equipment platforms. Buried horizontally around substation foundations it forms the earth ring that ties electrodes together. Inside data centers the tape runs beneath the raised floor as the equipotential ring, connecting rack grounding bars, SPD earth terminals, and cable tray bonding every 600mm. In explosive hazardous areas the tape bonds pipes, flanges, and instrument housings to prevent sparking. For photovoltaic farms it bonds mounting frames and inverter enclosures across long rows. The tape also serves as a flexible jumper between vibrating equipment and fixed grounding busbars, absorbing thermal expansion and mechanical movement.
Advantages
Flat copper tape has lower inductance than round conductor of equivalent cross section, so lightning impulse current sees a lower impedance path and the resulting voltage step is smaller. The wide face area improves soil contact for buried grids and reduces touch potential near the electrode. Coil format eliminates mid-run joints, which are the most common failure point in grounding networks. Hand-bendable format removes the need for hydraulic bending tools on site. KITOZER tape is compatible with all standard exothermic welding molds and mechanical clamps, so installers do not need special fittings. The PVC-sheathed version can be laid directly in acidic or saline soil without additional anticorrosive wrapping, saving excavation and backfill cost. Long design life of 30 to 50 years in neutral soil reduces whole life cost compared with galvanized steel tape.
Installation and Maintenance
For surface mounting, fix the tape on lightning protection clips at 500mm spacing vertically and 1000mm spacing horizontally, avoiding sharp bends smaller than 2.5 times width. For buried use, trench at minimum 0.5m depth in dry soil or 1.0m in frozen ground, backfill with low resistivity earth, and avoid contact with reinforcing steel unless intentional bonding is planned. Join tape with KITOZER exothermic welds for buried connections or listed mechanical clamps for above-ground accessible joints. After installation, test continuity and earth loop resistance. Inspect above-ground tape annually for mechanical damage, repaint or retouch tinned surfaces where scratch exposure occurs. In coastal zones check for salt corrosion every two years and clean with dry cloth, never use abrasive paper that would remove tin coating.
Price
From $18 per meter for 25x2mm bare copper tape. Tinned from $24 per meter. PVC sheathed from $32 per meter. Contact +86 13922289957 for coil pricing and lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com