KITOZER Cross Flow Cooling Tower 300T For Chiller Plant

The KITOZER 300T cross flow cooling tower is designed to reject condenser heat from 200RT to 350RT water chillers in commercial HVAC and industrial process cooling plants. The FRP pultruded shell and fill media deliver long service life with low maintenance, while the axial fan and gear reducer provide quiet operation suitable for urban buildings and hospital environments. Cross flow design allows easy access to fill and spray nozzles without draining the tower, reducing annual servicing time.

Cross flow towers position the fill media outside the air stream, so water flows vertically by gravity through the fill while air enters horizontally from the sides. This arrangement eliminates the pressure penalty of spray water distribution systems and allows the tower to operate efficiently at lower fan speeds. The large cold water basin below the fill provides adequate water volume to stabilise pump suction and accommodate thermal expansion during chiller cycling.

Product Overview

KITOZER cross flow towers feature a large surface PVC fill pack, gravity water distribution with non clogging spray nozzles, and a hot dip galvanized steel structural frame. The fan is axial type with aluminum or FRP blades, direct coupled to a low noise motor. The cold water basin is integrated with make up water float valve, drain, overflow, and access screen. Drift eliminators reduce water drift loss below 0.005 percent of flow. The unit can be supplied in single cell or multi cell configurations for large plants.

The distribution system uses large orifice nozzles that do not clog with suspended solids, making the tower tolerant of cooling tower water that may contain airborne dust and biological growth. The fill pack is made of UV stabilised PVC and can be removed in sections for inspection or replacement without dismantling the shell. A centrifugal spray type option is available for high temperature water above 45 C.

Technical Specifications

Nominal water flow 300 m3 per h. Design wet bulb 28 C, inlet water 37 C, outlet water 32 C, range 5 C. Air flow 180,000 m3 per h. Fan motor 11 kW, 4 pole, IE3. Fan diameter 1800 mm. Noise level 65 dB(A) at 10 m. Basin volume 6 m3. Water connection DN200 inlet, DN200 outlet. Operating weight 4200 kg. Materials: FRP shell, PVC fill, galvanized steel frame, copper motor winding. CE and ISO 9001 certified, 3 year shell warranty.

Application Scenarios

This tower is installed on rooftops, ground yards, or mechanical floors below chillers. Typical applications include office building central plants, hotel HVAC, hospital condenser loops, data center dry cooler backup, and industrial process cooling for injection molding, compressor aftercoolers, and furnace cooling. Multi cell towers allow staging fan operation to match chiller loading, saving fan energy during part load. The cross flow configuration is preferred when maintenance access must be fast and frequent.

In coastal regions, optional corrosion resistant package includes hot dip galvanized structure with additional epoxy coating and stainless steel fasteners. In cold climates, the tower can be fitted with an internal hot water basin heater and fan reverser cycle to prevent ice formation on intake louvers. Multi cell arrangements allow one cell to be taken offline for maintenance while the remaining cells carry the full chiller load.

Advantages and Features

FRP shell resists UV and atmospheric corrosion for outdoor installation. The gravity distribution system operates without pressure spray pipes, reducing clogging. Fill pack is removable for cleaning or replacement without dismantling the tower. Low sound fan option reduces noise by 5 dB(A) for noise sensitive sites. The tower is compatible with water treatment dosing systems and side stream filtration. Optional variable speed fan drive maintains constant condenser water temperature as wet bulb changes, saving chiller energy.

Compared with counter flow towers, cross flow units have lower fan horsepower because air enters the fill directly without turning. The basin is easier to clean because access is unobstructed. The large distribution deck allows visual inspection of water distribution without entering the tower. These features lower annual maintenance cost by 20 to 30 percent over the tower life.

Installation and Maintenance

Position the tower on a level concrete plinth with enough clearance for air inlet on all sides. Do not place tower exhaust near fresh air intakes. Connect condenser water pipes with flexible joints. Install a bypass line for winter operation if the plant may run below freezing. Commissioning includes checking fan rotation, water distribution uniformity, and float valve function.

Monthly inspection includes drift eliminator condition, basin cleanliness, and water treatment chemical levels. Annually clean fill pack with low pressure water and inspect fan blade bolts and gear reducer oil. Every five years, inspect the FRP shell for UV degradation and recoat if needed. Keep a log of water flow, water temperature, and fan motor current to track performance changes over time.

Price

From $6,800 per cell. Contact KITOZER for multi cell pricing and low noise option.