KITOZER CT: 10kV Current Transformer 600/5A Class 0.5

KITOZER 10kV current transformer (CT) steps down primary current to a standardized 5A or 1A secondary current for metering, protection, and monitoring. The CT provides galvanic isolation between the high voltage primary and low voltage secondary instruments, protecting personnel and equipment from high voltage surges. This model is rated 600/5A with 0.5 accuracy for metering and 10P10 for protection, making it suitable for feeder and transformer circuits in 10kV switchgear.

Product Overview

The CT is a sealed cast resin insulated pole unit with primary and secondary windings encapsulated in epoxy resin. The primary winding passes through the core window or is a bar type fixed through the pole. Secondary terminals are brought out to a terminal block inside the sealed housing. Cast resin construction eliminates oil and gas, prevents moisture ingress, and withstands vibration in withdrawable switchgear trucks. A terminal cover prevents accidental contact and provides tamper evidence for revenue metering.

Technical Specifications

Rated voltage 12kV, rated frequency 50/60Hz, primary current 600A, secondary current 5A, accuracy class 0.5 for metering and 10P10 for protection, rated output 15VA to 30VA, thermal rated current 1.2 times primary for continuous, short-time thermal current 20kA for 1s, dynamic rated current 50kA peak. Power frequency withstand 42kV for 1 minute, lightning impulse withstand 75kV peak. Insulation class E, ambient temperature minus 25 to plus 40 degrees Celsius. Compliant with IEC 61869-2 and GB 20840.

Applications

This CT is installed in KYN28A, XGN, and Ring Main Units on 10kV feeder panels, transformer incoming panels, and bus tie panels. The 0.5 winding feeds revenue or energy management meters, while the 10P winding feeds overcurrent and earth fault protection relays. It also supplies current signals for power quality analyzers and SCADA remote terminal units. Typical customers include industrial plant electrical rooms, commercial building substations, and utility distribution networks.

Advantages

Dual core design separates metering and protection windings so that large fault currents do not saturate the metering circuit and distort billing accuracy. Cast resin insulation requires no maintenance and is immune to moisture. The sealed housing prevents dust and condensation on secondary terminals. Accurate 0.5 class supports fair energy billing and effective load management. Compact dimensions fit standard switchgear compartments. The CT has a long service life of more than 30 years when operated within ratings.

Installation and Maintenance

Mount the CT on the switchgear bus or cable, observing primary and secondary polarity markings. Never open the secondary circuit while the primary is energized, as this produces dangerous overvoltage. Use shielded secondary cable with one end grounded at the relay panel. Commissioning includes ratio test, polarity test, insulation resistance test, and burden calculation to ensure the connected burden is within rated output. Inspect annually for resin cracks and terminal tightness. Calibrate metering CTs every four years according to local metering regulations. Keep secondary terminal covers sealed to prevent tampering.