KITOZER Current Sensor Split Core 100A 4-20mA For Power Distribution

The KITOZER split-core current sensor is a non-invasive current transformer designed for measuring AC current in power distribution panels, UPS output circuits, lighting panels, and motor feeders without breaking the existing conductor. The split-core design allows the sensor to clip around an existing cable while the panel is energized, eliminating the need for an outage during installation. The 4 to 20 mA output scales linearly from zero to the rated current, making integration into PLC, BMS, and KITOZER monitoring hosts straightforward.

Split-core CTs are the standard choice for retrofit projects because they do not require disconnecting the primary conductor. The KITOZER sensor uses a high-permeability nanocrystal core that maintains accuracy across a wide frequency range and minimizes phase shift, which is important when the sensor is used for power and energy measurement rather than simple current trending. The internal burden resistor and signal conditioner are housed in the sensor body, so only a 2-wire loop cable runs back to the monitoring input.

Product Overview

The sensor body is an ABS clamp with a hinge that opens around the primary conductor. A locking tab ensures the core closes fully, which is critical for accuracy. A 2-meter shielded cable exits the sensor and terminates in screw terminals for the 4 to 20 mA loop. Multiple ranges are available, from 50 A to 600 A, and the sensor can be installed on conductors up to 22 mm diameter for the 100 A model.

Technical Specifications

Range: 0 to 100 A AC. Output: 4 to 20 mA loop, 2-wire. Power: 12 to 24 VDC. Accuracy: plus or minus 1 percent of reading at 25 C. Burden: built-in, no external resistor required. Core material: nanocrystal. Primary conductor: up to 16 mm diameter. Frequency: 50 to 60 Hz. Operating temperature: -10 to +70 C. Insulation class: 300 VAC. Cable: 2 meter shielded. Enclosure: ABS, IP40. Certifications: CE, RoHS. KITOZER warranty: 2 years.

Application Scenarios

This sensor is used in data center PDU monitoring, UPS output trending, motor current load logging, lighting panel energy management, and sub-main distribution circuit monitoring. In a data center, multiple split-core CTs are installed on each PDU feeder circuit, and the KITOZER monitoring host logs current per circuit to identify imbalanced phases and overloaded branches. In a manufacturing plant, CTs on motor feeders provide load trending that predicts bearing wear before failure.

Advantages and Features

The split-core design allows hot installation, which is the primary advantage over solid-core CTs that require breaking the conductor. The nanocrystal core maintains accuracy better than cheaper ferrite cores, and the built-in burden eliminates the need for external resistors that can drift. The 4 to 20 mA output is noise-immune over long cable runs. KITOZER offers a full range of sizes, so a single design language works from 50 A lighting circuits to 600 A main feeders.

Installation and Maintenance Advice

Clip the sensor around a single conductor, not around both phase and neutral together, as that cancels the magnetic field. Ensure the core faces are clean and fully closed, and engage the locking tab. Calibrate the loop by reading 4 mA at zero current and 20 mA at full load during commissioning. Inspect the clamp annually for corrosion or dust, and verify that the locking tab has not vibrated loose. Replace the sensor if the core shows cracks or the output drifts beyond 2 percent.

Typical Deployment Configuration

In a data center PDU, KITOZER split-core CTs are clipped around each branch feeder conductor inside the PDU, and the 4 to 20 mA loops run back to an analog input module on the KITOZER monitoring host. The host displays current per branch circuit on a rack elevation diagram, making it easy to spot overloaded or imbalanced circuits. In a manufacturing plant, CTs on motor feeders provide load trending that predicts bearing wear: a motor that gradually draws more current over months indicates mechanical friction that requires maintenance before failure. The split-core design allows all of this to be installed without powering down the panel, which is essential for facilities that cannot tolerate an outage. KITOZER offers CTs in ranges from 50 A to 600 A, so a single product family covers lighting circuits, motor feeders, and main busbars. The nanocrystal core maintains accuracy across temperature swings, and the built-in burden resistor eliminates the need for external signal conditioning. For energy metering applications, KITOZER also offers a Modbus version of the same CT that publishes current directly over RS485, eliminating the need for separate analog input modules. The split-core design is UL recognized for field installation, and the locking tab prevents accidental opening under vibration. A full range of jaw sizes is available for conductors from 6 mm to 52 mm diameter.

Price

From $42 per unit. Contact +86 13922289957 for multi-CT panel pricing.