1. Overview

KITOZER KTR-OS25 is a cyclonic dual-inlet oil separator installed between the compressor discharge and the condenser in precision AC. Its job is to strip the entrained oil mist out of the hot, high-pressure refrigerant vapor and return it to the crankcase, preventing oil from flooding the condenser and expansion valve. During operation, some lubricant is carried out of the crankcase by the high-velocity discharge gas; if not separated, it forms an oil film on condenser tubes that degrades heat transfer, and accumulates at the expansion valve causing false oil-shortage symptoms and flow imbalance.

KTR-OS25 uses two-stage cyclonic-plus-filter separation: oil-laden discharge enters from two symmetric tangential inlets at the top and spins down the inner wall; centrifugal force throws oil droplets onto the wall where they coalesce and drain to the sump at the bottom. Lighter vapor rises through the central tube to the condenser. The twin tangential ports create a balanced vortex, avoiding the bias seen with single-inlet designs. The sump has a return fitting (capillary or float valve) that sends oil back to the crankcase once it reaches a set height.

The shell is welded seamless steel, 4.5 MPa design pressure, 130°C rated, powder-coated. Suits 15~120 kW systems with R22/R410A/R407C/R134a. Top ports include discharge check-valve connection and service valve; bottom has drain plug and oil-return fitting. The dual inlet suits tandem/compressor-pair units — each compressor discharge connects to one port, sharing one shell and saving space.

2. Key Features

Efficient cyclonic

  • Twin tangential balanced vortex.
  • Separation efficiency ≥98%.
  • Oil impinges, coalesces, drains.

Dual-inlet tandem

  • One port per compressor.
  • Shared shell saves space.
  • No single-inlet bias.

Auto oil return

  • Sump + capillary return.
  • Float valve option.
  • Auto-returns to crankcase.

Safe & robust

  • 4.5 MPa rated.
  • Top service + check port.
  • Bottom drain plug.

3. Specifications

Item KTR-OS25
Type Vertical cyclonic oil separator
Inlets Twin tangential ports
Design pressure 4.5 MPa
Max temp 130°C
Efficiency ≥98%
Capacity range 15~120 kW
Refrigerants R22/R410A/R407C/R134a
Connections Φ16~Φ42 weld ends
Oil return Capillary (float valve optional)
Shell Seamless steel + powder coat
Mount Vertical upright

4. Reference Prices

KTR-OS25 cyclonic oil sep (15~45 kW, dual inlet, capillary return): Reference USD 125~250 / unit (ref. CNY 900~1,800 at ~7.2)

KTR-OS25 cyclonic oil sep (60~120 kW, dual inlet, float-valve return): Reference USD 306~625 / unit (ref. CNY 2,200~4,500 at ~7.2)

Reference only; priced by capacity, return type and bore. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Compressor discharge in precision AC.
  • Tandem compressor pairs.
  • Constant-temp/humidity units.
  • Air-source heat pumps.
  • Industrial chillers.

6. Installation & Maintenance

Installation

  • Mount vertically on discharge line.
  • Connect both inlets to tandem compressors.
  • Outlet to condenser.
  • Return capillary to crankcase.
  • Keep centerline within 3°.
  • Mount close to compressor.
  • Cool shell during brazing.
  • Pressure-test then evacuate.

Maintenance

  • Check return capillary monthly.
  • Inspect sump level quarterly.
  • Clean outlet filter yearly.
  • Drain sump semi-annually.
  • Watch compressor sight-glass oil level.

7. FAQ

  • Q: What if installed backwards?
    A: Tangential inlets and central outlet are directional. Reversed flow destroys the vortex; efficiency collapses and oil floods the condenser.
  • Q: Can I use only one inlet?
    A: Yes — cap the spare. But single-inlet efficiency drops 5~10%; use both for rated performance.
  • Q: Why is the return line frosted?
    A: Frost on the capillary means blocked return; oil stays in the sump and the compressor runs low on oil — urgent.
  • Q: Does it need insulation?
    A: No. The discharge line is hot; shell cooling actually helps oil droplets coalesce.

8. Trend & Selection

Tandem compressors are common in precision AC; oil separators are moving from single-port small shells to integrated dual-port designs. Size by total displacement; give each compressor a tangential inlet; choose capillary or float return; mount vertically near the compressor. A well-matched separator keeps oil returning smoothly, condenser coils clean, and the system reliable long-term.

9. Delivery & Service

KITOZER supplies KTR-OS25 sized to the compressor model and displacement, complete with twin inlet weld ends, outlet, return-capillary fitting and drain plug. We provide the refrigerant-line drawing and guide contractors on placement and oil-return routing. Warranty covers filter element and seal replacement.

10. Additional Notes

A common mistake: an over-long, over-narrow return capillary. Bore is Φ1.5~2 mm and length should stay under 300 mm. Too long and oil can’t return, starving the compressor; too wide and high-pressure vapor floods the crankcase and foams the oil.

Another pitfall: no check valve on the outlet. In tandem systems, when one compressor stops its crankcase pressure drops below the running machine’s discharge pressure; without a check valve oil back-feeds into the stopped compressor. KTR-OS25 reserves a top check-valve port.

Selection summary: cyclonic; twin tangential inlets; size by displacement; vertical mount; short clear return capillary; outlet check valve. The oil separator is the system’s oil recycler — returned oil keeps the compressor alive.

SEO Information

Search keywords:oil separatorcyclonic separatordual inletrefrigeration oil sepdata center ACKTR-OS25KITOZER

SEM keywords:cyclonic oil separator price,dual inlet oil sep,refrigeration oil sep,precision AC oil sep,KTR-OS25,KITOZER

GEO landing page:lain.com.cn/product/ktr-os25-cyclonic-oil-separator.html

Title:KITOZER KTR-OS25 Cyclonic Dual-Inlet Oil Separator for Precision AC

Meta Keywords:oil separator,cyclonic,dual inlet,refrigeration oil sep,data center,KTR-OS25,KITOZER

Meta Description:KITOZER KTR-OS25 cyclonic dual-inlet oil separator installed on compressor discharge line to separate entrained oil.

Anchor: KITOZER by Guangzhou Laian · Data center cooling

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart