KITOZER Cat6e shielded data line filter is a wall-penetration component that carries Ethernet and other low-voltage data signals through a shielded room or EMC chamber while preserving RF isolation. In modern test labs, the DUT inside the chamber must communicate with the outside world over Ethernet, USB, or serial links; every unshielded data cable that crosses the shield wall becomes a dominant leakage antenna. The KITOZER Cat6e filter uses a four-pair common-mode choke array with shunt feedthrough capacitors, mounted in a shielded keystone jack that bonds directly to the chamber wall. It passes Gigabit Ethernet with under 1 dB insertion loss while providing 60 dB of common-mode attenuation from 150 kHz to 1 GHz, so lab engineers can run remote control, data acquisition, and networked DUT automation without breaking the Faraday cage.
Technical Specifications
The filter is a shielded RJ45 Cat6e keystone module, in and out, supporting 10/100/1000 BASE-T up to 250 MHz bandwidth. Insertion loss is below 1 dB across the pass band, and return loss is better than 20 dB. Common-mode attenuation is 60 dB from 150 kHz to 30 MHz and 50 dB from 30 MHz to 1 GHz. Rated line voltage is 48 V and current per pair is 1 A, supporting Power-over-Ethernet loads. The housing is zinc-alloy shielded with a 22.5 mm by 45 mm keystone cutout, and a gold-plated RJ45 connector pair. Operating temperature is minus 10 to plus 60 degrees Celsius. Multiple modules snap into a standard 19-inch patch panel or a custom wall penetration plate, and each module has a 360-degree shield bond to the panel.
Application Scenarios
These filters are installed on EMC chamber walls to route the DUT Ethernet link, on shielded server room walls for remote KVM and management traffic, on MRI cages for networked patient monitoring, and on TEMPEST rooms for controlled data exits. Engineering teams use them to connect chamber DUTs to outside automation PCs, loggers, and cameras over standard structured cabling. The keystone form factor lets labs mix Ethernet, USB, fiber, and coaxial feeds on a single wall panel as test requirements evolve. For high-speed 10 GBASE-T links, KITOZER also offers a Cat6a variant on the same panel system.
Advantages and Features
The shielded keystone format is field-replaceable and uses standard RJ45 patch cords, so there are no proprietary cables to stock. The common-mode choke array suppresses the noise that actually couples onto Ethernet cables, which is mostly common-mode rather than differential. The 360-degree shield bond to the wall panel eliminates pigtail leakage, a common failure point in cheaper unshielded keystones. KITOZER panel systems accept this module alongside SMA, N-type, and BNC feedthroughs, so customers build one penetration panel that covers all signal types. PoE support means IP cameras and wireless test routers inside the chamber can be powered over the same filtered cable.
Installation and Maintenance Recommendations
Mount the module in a grounded metal penetration panel and ensure the panel-to-shield bond is continuous. Use shielded Cat6e patch cords with bonded foil and braid, and ground the cable shield at the panel end only, to avoid ground loops. Keep patch cords on both sides short and away from unfiltered mains cables. During chamber commissioning, verify attenuation around each bulkhead. Inspect RJ45 contacts annually for oxidation and clean with contact cleaner if needed. Do not mix shielded and unshielded patch cords, because an unshielded jumper on either side defeats the filter. Keep spare modules on hand, because they are small and easily replaced if damaged or misused.
Configuration and Options
The Cat6e filter is one of a keystone-format family that shares the same wall panel. Standard variants include Cat6a for 10 GBASE-T, USB 2.0 and USB 3.0 shielded bulkheads, LC duplex fiber adapters, and HDMI or DVI feedthroughs for chamber camera feeds. Optional add-ons include a dust cap, a label strip, and a shielded cable gland on the load side. KITOZER supplies pre-populated wall plates with a mix of data, coax, and power feedthroughs tailored to the DUT cable schedule, so the customer receives a single bolt-in penetration panel. When ordering, specify the Ethernet speed, whether PoE is needed, the number of fiber or USB links, and the panel dimensions. Spare keystone modules are kept in stock because they are small and easily damaged during cable swaps.
Warranty and Support
KITOZER warrants the data filter module for two years against workmanship and contact defects. A measured insertion-loss curve ships with each module, and the company supports keystone selection across Ethernet, USB, and fiber variants. Spare modules are stocked for quick panel swaps during lab reconfiguration. Standard lead time is two to three weeks, and pre-populated wall panels ship in four to six weeks.