KITOZER
KITOZER

KITOZER DC Power Panel 220V 65Ah For Substation

Product Overview

The KITOZER 220V 65Ah DC power panel is a dedicated uninterrupted DC supply for substation protection, control, and trip circuits. It converts two utility AC feeds into a regulated 220V DC bus that powers protective relays, circuit breaker trip coils, indicator lamps, and remote terminal units during AC outages. The integrated battery charger, battery monitor, and distribution feeders in a single cabinet make it a turnkey solution for 35kV and 110kV substations, industrial power rooms, and large building electrical rooms.

Technical Specifications

DC bus: 220V nominal, adjustable 198V to 242V. Battery: 2V 100Ah VRLA or nickel-cadmium, 104 blocks in series, capacity 65Ah standby rating. Charger: 10A thyristor or high-frequency switch-mode, dual redundant modules optional. Input: 380V three phase, 50Hz, wide tolerance. Ripple: less than 1 percent on DC bus. Protection: overvoltage, undervoltage, overcurrent, short circuit, battery reverse, ground fault detection. Distribution: 12 to 24 feeders with miniature circuit breakers. Indicators: LCD showing bus voltage, charge current, battery current, feeder status. Communication: RS485 Modbus, optional Ethernet. Dry contacts: common fault, common alarm, battery low, charger fault. Enclosure IP20 floor standing. Compliance DL/T 459, GB/T 19826, CE.

Application Scenarios

The DC power panel is installed in 35kV and 110kV substations, industrial plant power rooms, large commercial building main switchrooms, and data center electrical rooms. It supplies DC power to protective relays, circuit breaker trip and close coils, emergency indicator lamps, remote terminal units, and communication equipment. It is the last line of defense when AC power is lost, ensuring that breakers can still be tripped and that protection relays remain alive to isolate faults.

Advantages and Features

KITOZER DC panels include dual redundant charger modules that hot-standby each other, so a single charger fault does not interrupt the DC bus. The battery monitor provides per-block voltage and internal resistance measurement, predicting weak blocks before they fail. The ground fault detection system locates the feeder with the insulation fault, reducing troubleshooting time. The HMI logs every alarm with timestamp, and supports scheduled battery discharge tests. Up to 4 panels can be paralleled for larger substations.

Installation and Maintenance

Install the cabinet in a clean, ventilated substation control room with ambient temperature between 20 and 25 degrees Celsius. Run battery cables in dedicated cable tray and size them to keep voltage drop below 1 percent. Commissioning requires a full-rate discharge test to verify 65Ah capacity, a ground fault detection test, and a trip coil operation test. Maintenance: quarterly visual and terminal check; annual battery conductance test, charger calibration, and ground fault detector verification; every five years replace charger filter capacitors and cooling fans.

Price

From $4,880 per cabinet including 65Ah battery bank. Contact +86 13922289957 for substation-specific configuration.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart