Table of Contents
Toggle1. System Overview
KITOZER DC Distribution Unit (DCDU) is the core power distribution equipment for 4G/5G base station DC power supply systems, specially designed for -48VDC communication power supplies. It undertakes centralized power distribution, overload/short-circuit protection, intelligent monitoring and secondary power-down management of electric energy output from rectifier modules and battery packs. It provides stable, safe and controllable DC power supply for BBUs, RRUs, AAUs, transmission equipment and monitoring terminals. Compatible with full-scenario deployments including macro base stations, micro base stations, edge computing nodes and outdoor cabinets, it features high reliability, high power density, easy maintenance and strong compatibility, serving as critical infrastructure to guarantee continuous and stable operation of 5G networks.

DC Distribution Unit
2. System Composition
- Input Unit: Equipped with -48VDC main input terminals, battery parallel terminals, B+C level lightning protection modules and EMI filter circuits, supporting dual redundant input from rectifiers and storage batteries.
- Power Distribution Busbar Unit: High-conductivity tinned oxygen-free copper busbars with anti-oxidation treatment, insulating supports and main circuit circuit breakers/fuses, realizing centralized power convergence and primary protection.
- Output Distribution Unit: Multiple independent output branches, each fitted with DC circuit breakers/fuses, quick-connect terminals and branch status indicator lights, supporting hot swapping and fault isolation.
- Monitoring & Management Unit: Voltage/current sampling modules, microcontrollers, RS485 communication interfaces, LED/LCD display modules and dry contact alarm outputs. It monitors real-time system operating parameters and supports remote management.
- Protection Function Unit: Integrated overvoltage/undervoltage protection, overcurrent/short-circuit protection, reverse polarity protection, secondary power-down control, insulation monitoring (high-end models) and lightning protection to fully safeguard system and load safety.
- Structural Unit: 19-inch standard rack-mount form factor (1U/2U height), cold-rolled steel cabinet with electrostatic spraying, front-rear ventilation heat dissipation design, front operation panel and protective grounding terminals.
3. System Classification
3.1 Classification by Power Level

3D Drawing of DCDU
- Low-Power Type (50A–100A): Model KITOZER-DCDU-50/100. Suitable for 5G micro base stations, indoor distribution systems and edge computing nodes, with 8–12 output channels and 5–10A per channel.
- Medium-Power Type (150A–200A): Model KITOZER-DCDU-150/200. Applied to 4G/5G macro base stations (1 BBU + 6 RRU configuration) and outdoor integrated cabinets, offering 10–16 output channels with 10–20A per channel.
- High-Power Type (250A–300A): Model KITOZER-DCDU-250/300. Designed for 5G ultra-dense networking base stations, centralized power distribution in base station equipment rooms and multi-carrier high-power AAU scenarios, featuring 16–24 output channels and 15–30A per channel.
3.2 Classification by Functional Features
- Basic Type: Pure power distribution and protection without monitoring functions, equipped with simple circuit breakers/fuses. Cost-effective for low-cost micro-station scenarios.
- Intelligent Type: Integrated voltage/current monitoring, RS485 communication, remote alarms and secondary power-down control, supporting Modbus-RTU protocol to meet intelligent operation and maintenance demands of base stations.
- Enhanced Type: Built on intelligent type with additional insulation monitoring, branch electric energy metering, temperature monitoring and local LCD display, supporting cloud platform access for high-reliability core base stations.
3.3 Classification by Installation Method

DCDU Production Line
- Rack-Mount: Installed in 19-inch standard cabinets with 1U/2U height, front operation and front-rear maintenance, compatible with indoor equipment rooms and integrated cabinets.
- Wall-Mount: Metal cabinet for wall mounting with IP54 protection grade, applicable to outdoor base stations, tower-mounted base stations and side installation of outdoor cabinets.
- Embedded: Integrated inside integrated base station power cabinets to save space, matching customized power system designs.
4. System Schematic Diagram
plaintext
┌────────────────┐ ┌────────────────┐
│ Rectifier Output │ │ Battery Pack │
│ -48VDC │ │ -48VDC │
└────────┬───────┘ └────────┬───────┘
│ │
└───────────┬───────────┘
│
┌────────────────────▼────────────────────┐
│ B+C Level Lightning Protection │
└────────────────────┬────────────────────┘
│
┌────────────────────▼────────────────────┐
│ EMI Filter Circuit │
└────────────────────┬────────────────────┘
│
┌────────────────────▼────────────────────┐
│ Main Circuit Breaker (QF0) │
└────────────────────┬────────────────────┘
│
┌────────────────────▼────────────────────┐
│ DC Convergence Busbar │
└────────────────────┬────────────────────┘
┌──────────┬────────┴────────┬──────────┐
│ │ │ │
QF1(5A) QF2(10A) QF3(20A) QF4(30A) Output Branches (Expandable to 24 Channels)
│ │ │ │
└──────────┼─────────────────┼──────────┘
│ │
┌──────────▼─────────────────▼────────────┐
│ Load Equipment (BBU/RRU/AAU, etc.) │
└───────────────────────────┬─────────────┘
│
┌───────────────────────────▼─────────────┐
│ Voltage/Current Sampling Module │
└───────────────────────────┬─────────────┘
│
┌───────────────────────────▼─────────────┐
│ Microcontroller (MCU) │
└───────────────────────────┬─────────────┘
┌──────────┬───────────────┴────────┬────┐
│ │ │ │
RS485 LCD Display Dry Contact Secondary Power-Down
Comm Interface Module Alarm Output Control Module
5. System Configuration List (Low / Medium / High Tiers)

On-site DCDU Installation
5.1 Low-Tier Configuration (Micro Base Station / Indoor Distribution)
表格
| No. | Product Name | Model Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DC Distribution Unit Host | KITOZER-DCDU-50-B | -48VDC input, 50A total current; 8 output channels (4×5A+4×10A); basic type without monitoring; 1U rack-mount; B-grade input lightning protection; fuse protection per channel; terminal size 2.5–6mm²; dimension 442×42×65mm; weight ≤1.5kg | 1 | Set | KITOZER | Basic power distribution, no communication |
| 2 | Input Cable | KITOZER-CAB-16-1M | 16mm² copper DC cable dedicated to -48VDC, 1m length, Class C flame retardant | 2 | Pcs | KITOZER | Rectifier / battery input connection |
| 3 | Output Cable | KITOZER-CAB-6-2M | 6mm² copper DC cable dedicated to -48VDC, 2m length, Class C flame retardant | 8 | Pcs | KITOZER | Load equipment connection |
| 4 | Mounting Bracket | KITOZER-BR-19-1U | 19-inch rack mounting bracket, cold-rolled steel with black electrostatic spraying | 1 | Set | KITOZER | Cabinet mounting fixture |
5.2 Medium-Tier Configuration (Standard Macro Base Station)
表格
| No. | Product Name | Model Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DC Distribution Unit Host | KITOZER-DCDU-200-S | -48VDC input, 200A total current; 12 output channels (6×10A+6×20A); intelligent type with monitoring; 1U rack-mount; B+C grade input lightning protection; hot-swappable DC breakers per channel; voltage/current monitoring; RS485 (Modbus-RTU); secondary power-down control; terminal size 2.5–10mm²; dimension 442×42×65mm; weight ≤1.8kg | 1 | Set | KITOZER | Intelligent power distribution, remote monitoring |
| 2 | Input Cable | KITOZER-CAB-50-1.5M | 50mm² copper DC cable dedicated to -48VDC, 1.5m length, Class C flame retardant, oil resistant | 2 | Pcs | KITOZER | Rectifier / battery input connection |
| 3 | Output Cable | KITOZER-CAB-10-2.5M | 10mm² copper DC cable dedicated to -48VDC, 2.5m length, Class C flame retardant, oil resistant | 12 | Pcs | KITOZER | Load equipment connection |
| 4 | Communication Cable | KITOZER-CAB-RS485-3M | Shielded twisted pair dedicated to RS485, 3m length, 120Ω impedance | 1 | Pcs | KITOZER | Monitoring communication wiring |
| 5 | Mounting Bracket | KITOZER-BR-19-1U | 19-inch rack mounting bracket, cold-rolled steel with black electrostatic spraying | 1 | Set | KITOZER | Cabinet mounting fixture |
| 6 | Surge Protector | KITOZER-SPD-DC-48 | -48VDC DC SPD, B+C grade, discharge current 40kA (8/20μs), response time ≤1ns | 1 | Set | KITOZER | Redundant input lightning protection |
5.3 High-Tier Configuration (High-Reliability Core Base Station)
表格
| No. | Product Name | Model Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | DC Distribution Unit Host | KITOZER-DCDU-300-E | -48VDC input, 300A total current; 24 output channels (8×10A+8×20A+8×30A); full-function enhanced type; 2U rack-mount; B+C grade input lightning protection; hot-swappable DC breakers per channel; voltage/current/temp monitoring; branch energy metering; insulation monitoring; RS485 + Ethernet communication; local LCD display; secondary power-down + battery protection; terminal size 2.5–16mm²; dimension 442×88×65mm; weight ≤3.5kg | 1 | Set | KITOZER | Full-function intelligent power distribution, cloud access |
| 2 | Input Cable | KITOZER-CAB-70-2M | 70mm² copper DC cable dedicated to -48VDC, 2m length, Class A flame retardant, oil & high temp resistant | 2 | Pcs | KITOZER | Rectifier / battery input connection |
| 3 | Output Cable | KITOZER-CAB-16-3M | 16mm² copper DC cable dedicated to -48VDC, 3m length, Class A flame retardant, oil & high temp resistant | 24 | Pcs | KITOZER | Load equipment connection |
| 4 | Communication Cable | KITOZER-CAB-RS485-5M | Shielded twisted pair dedicated to RS485, 5m length, 120Ω impedance, Class A flame retardant | 1 | Pcs | KITOZER | Monitoring communication wiring |
| 5 | Ethernet Cable | KITOZER-CAB-LAN-5M | Cat6 unshielded twisted pair, 5m length, supports 100Mbps transmission | 1 | Pcs | KITOZER | Cloud platform access wiring |
| 6 | Reinforced Mount Bracket | KITOZER-BR-19-2U | 19-inch rack mounting bracket, reinforced load-bearing, cold-rolled steel with black electrostatic spraying | 1 | Set | KITOZER | Cabinet mounting fixture |
| 7 | Premium Surge Protector | KITOZER-SPD-DC-48-PRO | -48VDC DC SPD, B+C grade, discharge current 60kA (8/20μs), response time ≤0.8ns, degradation alarm function | 1 | Set | KITOZER | Redundant high-performance input lightning protection |
| 8 | Insulation Monitoring Module | KITOZER-IM-48 | DC system insulation monitor, measures positive/negative pole-to-ground insulation resistance, alarm threshold 50kΩ, RS485 communication support | 1 | Set | KITOZER | System insulation safety monitoring |
6. Full Product Technical Specifications

DCDU Internal Circuit Board
6.1 KITOZER-DCDU-50-B (Low-Tier Basic Type)
- Input Specs: Rated voltage -48VDC (range -40VDC ~ -60VDC), rated current 50A, 2 input paths (rectifier + battery).
- Output Specs: 8 output channels (4×5A+4×10A), max 10A per channel, total 50A, output voltage consistent with input (-48VDC).
- Protection Specs: B-grade input lightning protection (20kA), fuse protection per channel (breaking capacity 10kA), reverse polarity protection, overcurrent protection (1.2× rated current).
- Mechanical Specs: 1U rack-mount, dimension 442W×42H×65D mm, weight ≤1.5kg, cold-rolled steel cabinet with black electrostatic spraying, IP30 protection grade.
- Environmental Specs: Operating temp -20℃ ~ +55℃, storage temp -40℃ ~ +70℃, relative humidity 10%–90% (non-condensing), altitude ≤2000m.
6.2 KITOZER-DCDU-200-S (Medium-Tier Intelligent Type)
- Input Specs: Rated voltage -48VDC (range -40VDC ~ -60VDC), rated current 200A, 2 input paths (rectifier + battery), B+C grade lightning protection (40kA).
- Output Specs: 12 output channels (6×10A+6×20A), max 20A per channel, total 200A, hot-swappable DC breakers for each branch.
- Monitoring Specs: Voltage monitoring (accuracy ±0.5%), total & branch current monitoring (accuracy ±1%), RS485 Modbus-RTU (9600bps baud rate), adjustable secondary power-down threshold, dry contact alarm (NO/NC).
- Protection Specs: B+C grade input lightning protection, circuit breaker per channel (breaking capacity 20kA), reverse polarity, overvoltage/undervoltage (-58VDC/-42VDC), overcurrent/short-circuit and battery over-discharge protection.
- Mechanical Specs: 1U rack-mount, dimension 442W×42H×65D mm, weight ≤1.8kg, cold-rolled steel cabinet, IP30 grade, front operation panel.
- Environmental Specs: Operating temp -20℃ ~ +55℃, storage temp -40℃ ~ +70℃, relative humidity 10%–90% (non-condensing); derate 1% per 100m above 2000m altitude (max 3000m).
6.3 KITOZER-DCDU-300-E (High-Tier Enhanced Type)

Outdoor Cabinet DCDU Commissioning
- Input Specs: Rated voltage -48VDC (range -40VDC ~ -60VDC), rated current 300A, dual input paths, B+C grade lightning protection (60kA) + EMI filter circuit.
- Output Specs: 24 output channels (8×10A+8×20A+8×30A), max 30A per channel, hot-swappable breakers, branch energy metering (accuracy ±0.5%).
- Monitoring Specs: Voltage/current/temp monitoring (±0.5%/±1%/±1℃ accuracy), insulation monitoring (0~1MΩ measuring range, 50kΩ alarm threshold), dual RS485+Ethernet (Modbus-RTU/TCP), local LCD display, secondary power-down & battery protection, dry contact alarm, cloud platform compatible.
- Protection Specs: B+C SPD + EMI filter, branch breakers (30kA breaking capacity), reverse polarity, over/under voltage (-58.5VDC/-41.5VDC), overcurrent/short-circuit, battery overcharge/over-discharge, insulation fault, overtemperature (derate at 85℃, shutdown at 95℃).
- Mechanical Specs: 2U rack-mount, dimension 442W×88H×65D mm, weight ≤3.5kg, cold-rolled steel, IP30 grade, front-rear ventilation, front operation panel, dedicated grounding terminal.
- Environmental Specs: Operating temp -25℃ ~ +60℃, storage temp -40℃ ~ +75℃, humidity 5%–95% (non-condensing), altitude ≤3000m (derate 1% per 100m above 3000m up to 5000m), seismic compliance with GB/T 2423.56.
6.4 Supporting Cables & Accessories Specifications

Central Monitoring Control Room
- KITOZER-CAB-16-1M: 16mm² oxygen-free copper DC cable for -48VDC, 1m length, Class C PVC flame retardant insulation, 1000VDC withstand voltage, operating temp -20℃ ~ +70℃.
- KITOZER-CAB-50-1.5M: 50mm² oxygen-free copper DC cable for -48VDC, 1.5m length, Class C flame retardant, oil-resistant per GB/T 16990, 1000VDC withstand voltage.
- KITOZER-SPD-DC-48: B+C grade -48VDC DC surge protector, 40kA (8/20μs) discharge current, response ≤1ns, voltage protection level ≤60VDC, leakage ≤10μA, operating temp -40℃ ~ +80℃.
- KITOZER-IM-48: DC insulation monitoring module for -48VDC, measuring range 0~1MΩ, ±5% measurement accuracy, 50kΩ alarm threshold, RS485 Modbus-RTU communication, operating temp -20℃ ~ +55℃.
7. Full Product Application Scope
7.1 Base Station Scenarios
- 5G Macro Base Stations: Supply -48VDC power to BBUs, RRUs, high-power AAUs, transmission equipment and monitoring terminals. Compatible with 1BBU+6RRU or multi-carrier high-consumption AAU deployments to meet high-power and high-reliability power supply demands.
- 5G Micro/Pico Base Stations: Applied to indoor building coverage, shopping malls, airports, stations and rural wide coverage sites, powering compact RRUs, distributed antennas and edge computing nodes with compact size and flexible installation.
- 4G Base Station Retrofit: Compatible with existing -48VDC rectifiers and batteries to add new power branches for 5G devices without large-scale system renovation, cutting upgrade costs.
- Outdoor Integrated Base Stations: Wide-temperature design, IP30 protection and high lightning resistance to withstand extreme heat, cold, humidity and lightning strikes for tower and field base stations.
7.2 Data Center & Equipment Room Applications

Internal View of Outdoor Power Cabinet
- Edge Computing Data Centers: Deliver -48VDC power to edge servers, switches and storage units under DC power architecture to lower PUE and boost energy efficiency.
- Centralized Base Station Room Power Distribution: Act as DC power hubs for small & medium base station equipment rooms, centrally managing multiple rectifier & battery groups to simplify wiring and improve O&M efficiency.
- Telecom Equipment Room Auxiliary Power: Supply DC power to transmission and core network equipment, monitoring systems and emergency lighting with secondary power-down function to prioritize core device power retention.
7.3 Other Industrial Scenarios
- Industrial Automation Control: Provide stable anti-interference -48VDC power to on-site PLCs, sensors, actuators and industrial switches.
- Rail Transit Communications: Power metro/high-speed rail base stations, signal equipment and monitoring devices with wide-temperature, seismic and high-reliability design for complex transit environments.
- New Energy Power Station Auxiliaries: Distribute DC power to communication monitoring systems and inverter control units of photovoltaic/wind power stations for both off-grid and grid-tied operation.
8. Core Product Advantages
8.1 Key Functional Strengths
- Ultra-High Reliability Design Adopts tinned high-conductivity copper busbars to reduce contact resistance and temperature rise; core components sourced from top international brands (Schneider/ABB circuit breakers, TI microcontrollers); dual redundant rectifier+battery input avoids full power loss from single-path faults; B+C level lightning protection suppresses lightning surge impact effectively.
- Intelligent Monitoring & Remote Management Intelligent/enhanced models integrate high-precision voltage/current/temperature sampling for real-time status tracking; RS485/Ethernet with Modbus-RTU/TCP enables integration with base station environment monitoring and cloud platforms for remote parameter configuration and alarm push; local LCD on enhanced models simplifies on-site maintenance; adjustable secondary power-down thresholds cut non-critical loads sequentially during mains failure to extend battery backup for core equipment.

Rack-Mounted DCDU Cabinet Array
- Flexible Configuration & Expandability Customizable output channels (8–24) and branch current ratings (5A/10A/20A/30A) match diverse load power; hot-swappable breakers/fuses allow single-branch replacement without disrupting other loads; standard 19-inch rack-mount compatible with all industry cabinets, plus wall/embedded mounting options for outdoor cabinets and integrated power systems.
- Comprehensive Multi-Layer Protection Full protection suite: overvoltage/undervoltage, overcurrent/short-circuit, reverse polarity, lightning surge, insulation monitoring (enhanced models), overtemperature and battery overcharge/over-discharge. Independent branch protection isolates faulty circuits to prevent fault propagation; maximum 30kA breaking capacity safely interrupts short-circuit currents to protect wiring and terminal equipment.
- Extreme Environmental Adaptability Enhanced type operating temperature range: -25℃ ~ +60℃ for desert high heat and frigid cold environments; IP30 dust & foreign object ingress protection; seismic performance compliant with GB/T 2423.56 for tower and vehicle-mounted vibration scenarios; UL94 V0 flame retardant materials improve fire safety.
8.2 Customization & Service Advantages
- Deep Customization Capability: Customizable output channel quantity, branch current rating, communication interfaces, protection thresholds and cabinet dimensions; optional add-ons including energy metering, insulation monitoring and temperature control; cross-brand compatibility with all mainstream rectifiers and battery brands.
- OEM/ODM Processing Support: Full white-label OEM service with custom appearance and function development based on client design drawings; large-scale production capacity with short lead times to support massive project delivery.
- Strict Confidentiality Mechanism: Sign non-disclosure agreements for all customized solutions, technical specs and design blueprints; internal classified data management to protect client intellectual property and core competitiveness.
- Ample Spot Inventory: Regular low/medium-tier models kept in stock for immediate delivery; pre-stocked core components to mitigate supply chain volatility; fast mass production scheduling for large-batch orders.
- End-to-End Technical Support: Free supply of technical, installation and maintenance manuals; complimentary technical consulting, solution design and on-site commissioning guidance; regular professional training for client O&M staff covering operation, maintenance and fault diagnosis.
9. Bid Evaluation Specifications (Marked with *)
9.1 General Bid Specifications
-
- DC input voltage: -48VDC (operating range -40VDC ~ -60VDC), compliant with telecom industry standard power voltage.
-
- Total input rated current: ≥50A (low-tier), ≥200A (medium-tier), ≥300A (high-tier) to meet diverse base station load power demands.
-
- Output channel quantity: ≥8 (low-tier), ≥12 (medium-tier), ≥24 (high-tier) for flexible load expansion.
-
- Lightning protection grade: Built-in B+C level input SPD, minimum discharge current ≥40kA (medium-tier), ≥60kA (high-tier).
-
- Communication interfaces: Intelligent/enhanced models standard with RS485 Modbus-RTU; high-tier models add Ethernet for cloud platform interconnection.
-
- Operating temperature range: -20℃ ~ +55℃ (low/medium-tier), -25℃ ~ +60℃ (high-tier) for harsh field deployment.
-
- Protection grade: IP30 dust-proof and foreign object resistant to secure equipment stable operation.
9.2 Low-Tier (KITOZER-DCDU-50-B) Bid Specifications
-
- Output channel allocation: 4×5A + 4×10A, maximum single branch current ≥10A.
-
- Protection form: Fuse per branch with breaking capacity ≥10kA.
-
- Mechanical dimension: 1U rack-mount, 442mm width, height ≤42mm, depth ≤65mm.
9.3 Medium-Tier (KITOZER-DCDU-200-S) Bid Specifications
-
- Output channel allocation: 6×10A + 6×20A, maximum single branch current ≥20A.
-
- Protection form: Hot-swappable DC circuit breakers per branch with breaking capacity ≥20kA.
-
- Monitoring capability: Total voltage, total current and individual branch current measurement; voltage accuracy ≤±0.5%, current accuracy ≤±1%.
-
- Control function: Adjustable secondary power-down voltage threshold (-42VDC ~ -48VDC).
9.4 High-Tier (KITOZER-DCDU-300-E) Bid Specifications
-
- Output channel allocation: 8×10A + 8×20A + 8×30A, maximum single branch current ≥30A.
-
- Protection form: Hot-swappable breakers (30kA breaking capacity); integrated insulation monitoring and overtemperature protection.
-
- Monitoring capability: Voltage/current/temperature/branch energy metering (energy accuracy ≤±0.5%); insulation resistance measuring range 0~1MΩ, alarm threshold ≤50kΩ.
-
- Display function: Equipped with local LCD screen for real-time system parameter, operating status and alarm information visualization.
10. Complete Product Solutions
10.1 5G Macro Base Station DC Power Distribution Solution
- Solution Overview: Adopt KITOZER-DCDU-200-S (medium intelligent) or KITOZER-DCDU-300-E (high enhanced) for -48VDC macro base station power supply, delivering stable, intelligent and reliable DC power to BBUs, RRUs, high-power AAUs, transmission and monitoring terminals to satisfy high power consumption, high reliability and smart O&M requirements.
- System Architecture: -48VDC power from rectifiers and battery packs are connected in parallel to DCDU input; power passes internal lightning protection, filtering and busbar convergence before distributed to each load via independent output branches; DCDU links to base station environment monitoring through RS485 for remote monitoring, alarm and control.
- Configuration Recommendation: Standard 1BBU+6RRU macro base stations deploy DCDU-200-S with 12 output channels (6×10A+6×20A) to cover power demands of BBU (10A), six RRUs (15A each), transmission equipment (10A) and monitoring terminal (5A). High-power multi-carrier AAU sites select DCDU-300-E with 24 output channels to support high-consumption AAU loads.
- Solution Advantages: Intelligent remote monitoring cuts labor O&M costs; multi-layer protection minimizes downtime from equipment faults; adjustable secondary power-down extends battery backup time for critical network gear; wide-temperature design ensures stable performance in outdoor harsh environments.
10.2 5G Micro Base Station DC Power Distribution Solution
- Solution Overview: Deploy KITOZER-DCDU-50-B (low basic type) for cost-effective, compact -48VDC power distribution for small RRUs, distributed antennas and edge computing nodes in micro/pico base station dense coverage scenarios.
- System Architecture: Integrated micro base station power supply (rectifier + battery) feeds -48VDC power directly into DCDU input; power is converged and protected internally then split across 8 independent output branches for connected loads, with no complex communication functions to reduce overall project cost.
- Configuration Recommendation: Single micro base stations (1 compact RRU + 1 distributed antenna + 1 edge computing node) adopt DCDU-50-B with 8 output channels (4×5A+4×10A); wall-mounted installation fits outdoor cabinet sides and building weak-current boxes.
- Solution Advantages: Ultra-compact lightweight design for flexible wall mounting and space savings; cost-optimized basic protection meets micro-station budget targets; built-in lightning and overcurrent protection withstands outdoor voltage fluctuations and lightning strikes; tool-free quick installation accelerates site deployment.
10.3 4G Base Station Retrofit to 5G DC Power Distribution Solution
- Solution Overview: Utilize KITOZER-DCDU-200-S (medium intelligent) to expand power capacity of legacy 4G -48VDC power systems by adding dedicated power branches for new 5G equipment. Fully compatible with existing rectifiers and batteries to avoid full power system replacement and lower upgrade investment, enabling mixed 4G/5G load power supply.
- System Architecture: Original 4G rectifiers and battery packs feed power to new DCDU input; DCDU output channels split into two groups: reserved circuits for legacy 4G gear and new dedicated branches for added 5G RRUs. RS485 links integrate DCDU with existing environment monitoring systems for unified 4G/5G power supervision.
- Configuration Recommendation: 4G macro base stations upgraded with 2–3 new 5G RRUs deploy DCDU-200-S with 12 output channels: 4–6 channels retained for original 4G equipment, 6–8 allocated to new 5G radio units. The solution reuses existing power infrastructure, eliminating rectifier and battery replacement costs with only incremental DCDU and cable investments.
- Solution Advantages: Full backward compatibility with legacy 4G power systems reduces renovation cycle and capital expenditure; centralized intelligent monitoring unifies power asset management for both 4G and 5G networks to boost O&M efficiency; independent branch fault isolation ensures 4G network continuity even if new 5G equipment malfunctions; expandable output capacity supports future incremental 5G equipment rollout.
11. Product Application Case Studies
11.1 Tier-1 Operator 5G Macro Base Station Construction Project
- Project Profile: In 2025, a major telecom operator built 100 5G macro base stations across Guangzhou, Guangdong Province to cover central urban zones, industrial parks and transport hubs, requiring high reliability, intelligent remote O&M and wide-temperature environmental adaptability under -48VDC DC power architecture.
- Deployment Configuration: Each site equipped with one KITOZER-DCDU-200-S medium intelligent DCDU with 12 output channels (6×10A+6×20A); input connected to 48V/200A rectifier and two sets of 48V/500Ah batteries; output powers 1×BBU (10A), 6×RRUs (15A each), 1×transmission device (10A) and 1×base station monitoring terminal (5A); DCDU communicates with site environment monitoring via RS485.
- Operational Outcomes: Zero unplanned downtime with 99.999% power supply availability; real-time remote monitoring and automatic alarm push lift O&M efficiency by 80%; secondary power-down function extends core equipment battery backup duration by 30% during mains outages; wide-temperature design maintains stable operation through Guangzhou’s high-temperature summers and humid rainy seasons.
11.2 China Tower 5G Micro Base Station Coverage Project
- Project Profile: In 2025, China Tower deployed 500 5G micro base stations in Shenzhen, Guangdong Province for indoor building, shopping mall and subway entrance dense coverage, with strict requirements for compact dimensions, flexible wall mounting, low total cost and high operational stability.
- Deployment Configuration: Each micro site fitted with one KITOZER-DCDU-50-B basic DCDU with 8 output channels (4×5A+4×10A); input fed by integrated 48V/50A rectifier + 48V/100Ah battery power unit; output supplies 1×compact RRU (10A), 1×distributed antenna (5A) and 1×edge computing node (10A); wall-mounted installation on outdoor cabinet side panels and building weak-current enclosures.
- Operational Outcomes: Compact lightweight hardware cuts on-site deployment cycle by 50%; cost-effective basic protection reduces overall project investment by 30%; built-in lightning and overcurrent protection suppresses outdoor voltage surges and lightning events with equipment failure rate below 0.5%; stable year-round operation under Shenzhen’s hot humid climate.
11.3 Provincial-Wide 4G to 5G Base Station Retrofit Capacity Expansion Project
- Project Profile: A provincial telecom operator retrofitted 300 existing 4G macro base stations in 2025 by adding new 5G RRU radio units, requiring legacy power system compatibility, low renovation cost, rapid construction and unified power monitoring for mixed 4G/5G loads.
- Deployment Configuration: Each retrofit site installed one KITOZER-DCDU-200-S intelligent DCDU with 12 output channels; input directly taps original 48V/200A rectifiers and battery packs from legacy 4G power systems; output allocates 4 branches to existing 4G BBUs, transmission and monitoring gear, with 8 dedicated branches for new 5G RRUs; RS485 integration with original environment monitoring systems delivers centralized 4G/5G power supervision.
- Operational Outcomes: Full compatibility eliminates rectifier and battery replacement, cutting renovation cycle by 60% and total project cost by 40%; unified intelligent monitoring streamlines mixed network power asset management and lifts O&M efficiency by 70%; independent branch protection ensures new 5G equipment faults cannot disrupt legacy 4G network operation; modular expandable output capacity supports future incremental 5G radio unit additions.
12. Common Product Faults & Maintenance Guidelines
12.1 Typical Faults & Troubleshooting Methods
- Fault Phenomenon 1: Normal input voltage, zero output voltage
- Root Causes: Tripped main circuit breaker / blown main fuse; reversed input polarity; damaged surge protector; loose internal busbar connections.
- Resolution: Inspect and replace faulty main breakers/fuses; rewire input positive/negative terminals to correct polarity; test and replace failed SPD; power off equipment then tighten loose internal busbar fasteners.
- Fault Phenomenon 2: Single branch no output voltage, all other branches functional
- Root Causes: Tripped branch breaker / blown branch fuse; loose output wiring terminal; short-circuit or overload on connected load.
- Resolution: Replace faulty branch breakers/fuses; retighten output terminal wiring; disconnect load equipment to test for short-circuit/overload conditions and resolve load faults before reconnection.
- Fault Phenomenon 3: Large deviation in voltage/current monitoring readings
- Root Causes: Damaged sampling module; loose sampling wiring; incorrect monitoring parameter calibration settings.
- Resolution: Replace defective sampling modules; tighten loose sampling wiring terminals; access monitoring configuration menu to recalibrate voltage and current measurement parameters.
- Fault Phenomenon 4: Communication failure, no remote monitoring access
- Root Causes: Loose RS485/Ethernet wiring; mismatched communication configuration parameters; damaged communication interface module.
- Resolution: Retighten communication cable terminals; verify and reconfigure communication address, baud rate and protocol type; replace faulty communication modules and conduct connectivity testing.
- Fault Phenomenon 5: SPD fault alarm indicator illuminated
- Root Causes: SPD damaged from lightning surge strike; end-of-life SPD degradation.
- Resolution: Replace degraded/failed SPD units; inspect site grounding system to ensure grounding resistance ≤4Ω for improved lightning surge suppression performance.
12.2 Routine Maintenance Schedule
- Daily Inspection: Check power, alarm and communication status indicator lights for no active faults; review LCD voltage/current readings (intelligent/enhanced models) to confirm nominal operating parameters; inspect cabinet exterior for abnormal overheating, burnt odors or mechanical noise.
- Weekly Maintenance: Retighten all input/output wiring terminals to prevent thermal runaway from loose connections; wipe cabinet exterior dust to maintain unobstructed ventilation; verify SPD health status with no fault alarms; test remote communication link functionality.
- Monthly Maintenance: Inspect breaker/fuse physical condition and test tripping function; calibrate voltage/current monitoring accuracy; audit grounding connection integrity; back up monitoring system configuration parameters to prevent data loss.
- Quarterly Maintenance: Fully power off equipment then open cabinet housing to remove internal dust buildup; inspect busbars and terminals for oxidation/corrosion; check capacitors, relays and active components for aging signs; conduct DC insulation resistance testing of the full power system.
- Annual Overhaul: Full performance testing of all hardware modules, replace aging degraded components; complete SPD lightning protection performance verification; inspect cooling fan operation and replace faulty fans; conduct full-load capacity testing to validate nominal power delivery capability.
12.3 Maintenance Safety Precautions
- Safe Operating Procedures: Cut off both rectifier and battery input power before any maintenance work, post “No Switch-On” warning signage; wear insulated gloves and safety goggles during all live-adjacent operations to prevent electric shock; strictly prohibit disassembly of internal components under powered conditions to avoid short-circuit hazards.
- On-Site Environmental Requirements: Perform maintenance only in dry, clean spaces to prevent moisture/dust ingress into equipment internal circuits; restrict working ambient temperature between 0℃ ~ +40℃ to avoid high-temperature component degradation during service.
- Spare Parts Management: Maintain local stock of consumable spare parts including circuit breakers, fuses, SPDs and communication modules for rapid fault recovery; store spare inventory in dry ventilated storage and conduct periodic stock health inspections.
- Maintenance Record-Keeping: Establish dedicated equipment maintenance files to log all inspection, service and fault resolution events; conduct regular data analysis of maintenance records to predict potential pre-fault conditions and implement predictive maintenance planning.
13. Factory Strength & After-Sales Service
13.1 Manufacturing & R&D Strength
- Enterprise Qualifications: KITOZER brand belongs to Guangzhou Le’an Intelligent System Development Co., Ltd., a national high-tech enterprise and “Specialized, Refined, Unique & Innovative” enterprise certified under ISO9001 Quality Management, ISO14001 Environmental Management and ISO45001 Occupational Health & Safety Management Systems. All products hold CE, UL and RoHS compliance certifications.
- Production Scale: 10,000㎡ modern manufacturing workshop equipped with automated SMT placement machines, wave soldering equipment, full-load aging test cabinets and precision testing instruments; annual DCDU production capacity reaches 100,000 units to support large-scale national and international project delivery schedules.
- R&D Capability: In-house R&D team of over 30 engineers including 10 senior electrical engineers specializing in telecom and DC power distribution hardware development; annual R&D investment accounts for 15% of corporate revenue with over 20 registered invention and utility model patents leading industry technical standards.
- Quality Control System: Full lifecycle quality oversight covering raw material procurement, production assembly and finished goods factory inspection; all core electronic components sourced from top global brands (Schneider, ABB, TI, Philips); 100% full-load 48-hour aging testing, functional testing and insulation withstand voltage testing for all finished products; zero defective goods shipped with a factory pass rate of 99.98%.
13.2 After-Sales Service Commitments
- Warranty Policy: All KITOZER DCDU units carry a 3-year free manufacturer warranty starting from factory acceptance date; free repair and component replacement for non-human-induced faults within warranty term; lifetime post-warranty maintenance service only charging component material costs with zero labor fees.
- Service Response Mechanism: 7×24-hour technical support hotline with 1-hour initial response to customer inquiries; complete troubleshooting solution delivered within 4 hours; on-site engineer dispatch within 24 hours for critical faults in domestic first-tier cities, 48 hours for remote rural regions; remote telephone/video technical support for real-time fault diagnosis and parameter configuration guidance.
- Installation & Commissioning Support: Complimentary supply of product installation and commissioning manuals; free on-site engineer dispatch for wiring guidance, system commissioning and startup validation; free professional technical training for client O&M teams covering hardware operation, routine maintenance and fault troubleshooting to build independent in-house service capability.
- Customization Service: Free dedicated power distribution solution design tailored to project load profiles, deployment environments and client technical specifications; full custom hardware development for unique functional, interface and dimensional requirements; full white-label OEM/ODM contract manufacturing with client brand branding support.
- Spare Parts Logistics Network: National spare parts warehouse network stocking fast-moving consumables (breakers, fuses, SPDs, communication modules) in major cities for emergency expedited shipping; standby unit allocation for large-batch turnkey projects to eliminate network downtime during equipment repair; 3-day delivery lead time for standard spare parts, maximum 7 days for custom spare parts.
14. Conclusion
As the core power distribution hardware for 4G/5G base station -48VDC DC power systems, KITOZER DC Distribution Units deliver stable, secure and controllable power supply to BBUs, RRUs, AAUs, transmission gear and monitoring terminals, supported by high-reliability engineering, intelligent remote monitoring, flexible modular expansion, full-spectrum protection and extreme environmental adaptability.
The full product portfolio spans low/medium/high power tiers with basic, intelligent and enhanced functional variants, fully compatible with all mainstream deployment scenarios including 5G macro base stations, micro base stations and legacy 4G network retrofits. Additional cross-industry applications cover edge computing data centers, industrial automation and rail transit communication systems for broad market versatility.
Backed by robust independent R&D capacity, automated manufacturing infrastructure, rigorous end-to-end quality control and comprehensive lifecycle after-sales service, KITOZER provides turnkey one-stop solutions covering solution design, custom hardware development, mass production, on-site commissioning and long-term maintenance. We help telecom operators and enterprise clients accelerate 5G network rollout, reduce capital and operational expenditure and maximize end-to-end network stability.
Moving forward, KITOZER will continue to focus investment on telecom DC power distribution technology R&D, iteratively optimize hardware performance, upgrade intelligent monitoring functionality and expand cross-industry application scenarios. We aim to deliver more premium, reliable and smart DC power distribution solutions to support nationwide 5G infrastructure construction and digital economy growth, forging long-term win-win partnerships with all industry stakeholders to build the next generation 5G communications ecosystem.
15. Search Keywords & SEO Tags
15.1 Search Keywords
- Core Keywords: 4G/5G base station DC distribution unit, KITOZER DCDU, -48VDC DC distribution unit, base station DCDU, 5G base station DC power distribution solution
- Long-Tail Keywords: 5G macro base station DC distribution unit, 5G micro base station DCDU, 4G to 5G base station retrofit DC power distribution, outdoor base station DC distribution unit, intelligent DCDU, DC distribution unit manufacturer, KITOZER DCDU-200-S, KITOZER DCDU-300-E
15.2 Hashtag Tags
#DCDU #DCDistributionUnit #KITOZER #4GBaseStation #5GBaseStation #BaseStationPowerDistribution #-48VDC #IntelligentPowerDistribution #TelecomPowerSupply #EdgeComputing #IndustrialPowerDistribution #RailTransitCommunications #BaseStationRetrofit #OutdoorBaseStation