KITOZER
KITOZER

KITOZER DCIM Software Platform For Medium Data Center

Product Overview

The KITOZER DCIM software platform is an integrated data center infrastructure management suite designed for small and medium data centers, server rooms, edge computing nodes, and enterprise IT closets. The software brings together power monitoring, environmental monitoring, cooling monitoring, asset management, capacity planning, and alarm management into a single web-based dashboard, allowing facility and IT teams to see the real-time state of every rack, circuit, and sensor without switching between vendor-specific tools. The platform runs on a standard 1U server appliance or as a virtual machine on VMware, Hyper-V, or KVM, and supports up to 5,000 monitoring points out of the box with optional expansion licenses for larger deployments.

Data collection is performed by KITOZER environmental monitoring hosts, smart PDUs, UPS, precision air conditioners, and building management systems connected over Modbus TCP, Modbus RTU over RS485, SNMP v2c and v3, BACnet IP, and HTTP APIs. Collected data is stored in an embedded time-series database with a default retention of 12 months for raw values and 5 years for hourly averages, allowing trend analysis of power usage, rack temperature, and humidity drift over long periods. The web dashboard is accessible from Chrome, Edge, or Firefox on desktop and tablet, and a mobile companion app delivers push alarms to on-call engineers.

Technical Specifications

Software architecture: multi-tier web application with embedded time-series database, 64 bit Linux host. Monitoring points: 5,000 per server node, expandable to 50,000 with distributed collector nodes. Protocols supported: Modbus TCP, Modbus RTU, SNMP v1, v2c, v3, BACnet IP, M-Bus, HTTP REST, OPC UA. Dashboards: drag-and-drop layout, floor plan visualization, rack elevation view, Sankey power flow diagram, Gantt change window. Alarm engine: threshold, rate-of-change, digital state, and logic combination alarms, with escalation to SMS, e-mail, WeChat, and webhook. Reports: PDF scheduled reports, Excel export, compliance audit trail. User management: role-based access control, multi-tenant, LDAP and Active Directory integration. Redundancy: active-standby cluster with automatic failover. Hardware appliance option: 1U rack server, 2 redundant PSUs, 2 network ports, 8 GB RAM, 2 TB SSD. Five year software maintenance included in first year, CE and FCC certified.

Application Scenarios

The KITOZER DCIM platform is deployed in enterprise data centers of 20 to 200 racks, co-location facilities, government server rooms, financial core computer rooms, hospital data centers, university IDC rooms, and telecom edge nodes. Typical use cases include real-time rack temperature and hot spot detection, PDU circuit-level power metering, UPS battery runtime trend analysis, chilled water leakage alerting, rack U-space and asset management, power usage effectiveness tracking, and change window management for scheduled maintenance. Co-location operators use the multi-tenant feature to show each tenant their own rack power and environment data without revealing neighboring tenants. Facility managers use the scheduled PDF reports to demonstrate compliance to internal audit and external certification bodies.

Key Advantages

The first advantage is vendor-neutral integration. Instead of locking customers into a single UPS or cooling brand, the platform speaks standard protocols and reads data from dozens of equipment models out of the box, reducing the risk that a future UPS replacement will require a new monitoring system. The second advantage is visual floor plan and rack elevation. Operators can click on a rack on the floor plan and immediately see which U positions are occupied, which devices consume how much power, and which temperature sensors inside the rack are approaching threshold. This visual context shortens troubleshooting time compared with raw alarm lists. The third advantage is alarm escalation. The software follows a configurable on-call rotation, sending alarms first to the primary engineer by push notification, then to the secondary engineer by SMS if no acknowledgement is received within five minutes, and finally to the operations manager by phone call. This reduces missed alarms during off-hours. The fourth advantage is data ownership. All time-series data is stored on the customer own server, not in a public cloud, supporting data sovereignty and privacy requirements in finance, government, and healthcare.

Installation and Maintenance Recommendations

Deploy the DCIM server on a dedicated 1U appliance or a reserved virtual machine with at least 8 GB RAM and 2 TB SSD. Connect the monitoring network interface to a VLAN that reaches the environmental monitoring hosts, smart PDUs, and UPS devices, and connect the client interface to the corporate office network for operator access. During commissioning, import the facility floor plan as a background image, drag sensor icons onto the correct positions, and name each point according to the customer naming convention. Configure threshold alarms with a 10 minute warm-up period after startup to avoid false alarms during boot. Set up daily backup of the configuration and weekly backup of the time-series database to a separate storage location. Maintenance tasks include reviewing alarm logs monthly to tune thresholds, applying software updates during a scheduled change window, and archiving older time-series data to cold storage once the 12 month retention is reached. Conduct an annual failover test of the active-standby cluster to confirm that alarms continue to flow when the primary node is shut down.

Price

From $3,800 per 5,000-point software license, including one year of maintenance. Contact +86 13922289957 for enterprise pricing, multi-site licensing, and virtual machine deployment package.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart