Table of Contents
ToggleProduct Overview
The KITOZER dense (sandwich) busway 1000 A is a compact enclosed busbar system used to carry large currents from low voltage switchgear to distribution boards in data centers, industrial plants, high rise buildings, and shopping malls. Copper conductors are stacked with insulation between phases in a sandwich arrangement, giving very low magnetic field, compact dimensions, and high short circuit withstand. The aluminum or steel housing provides mechanical protection and IP54 dust and water resistance. Plug in tap off boxes allow power to be tapped along the run for floor distribution, eliminating large cable trunks.
Technical Specifications
Rated current 1000 A, rated voltage 400 V three phase four wire plus PE. Conductor copper, tin plated. Insulation class F. Dielectric strength 3.5 kV for 1 minute. Peak withstand 50 kA, short time withstand 35 kA for 1 second. Enclosure IP54. Standard section length 2 m. Tap off boxes rated 63 A, 125 A, 250 A. Phase arrangement A-B-C-N stacked. Temperature rise 100 K. Losses per meter at rated current typically 250 W. Complies with IEC 61439-6, GB/T 8349.
Application Scenarios
Dense busway is used in data center main power runs, high rise building vertical risers, industrial plant overhead distribution, shopping mall floor feeders, and convention center power. Sandwich construction allows wall or ceiling mounting with small clearance. Plug in tap off boxes supply floor distribution boards, UPS units, and large air conditioning units. Compared with cables, busway is easier to extend, has lower magnetic field, and requires less installation labor. Fire barrier boxes seal the run where it passes through walls.
Advantages
Compact sandwich design saves space. Low magnetic field reduces electromagnetic interference. Copper conductors give low loss. Plug in taps allow flexible load addition. IP54 enclosure suits dust and splash environments. Standard 2 m sections with bolted joints speed installation. Fire rated barrier options. Five year warranty.
Installation and Maintenance
Support sections every 2 m with hangers or brackets. Maintain phase sequence and joint torque. Use joint kits supplied with each section. After installation, perform insulation test and contact resistance check. Maintenance annually: torque joints, inspect tap off boxes, clean enclosure. Every five years: infrared scan under load for hot joints. Keep tap off boxes closed when not in use. Do not exceed tap off rating.
Price
From $280 per meter including copper conductors, 2 m sections, and joint kits. Tap off boxes, fire barriers, and angle fittings are optional.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com