KITOZER diesel engine driven fire pump model DP-80-08 is a centrifugal pump coupled through a heavy-duty SAE flywheel housing to a turbocharged water-cooled diesel engine, engineered for sites where the electrical grid is unreliable or where insurance loss-prepection rules require an independent power source. The unit delivers 80 liters per second at 0.85 megapascal discharge pressure, covering sprinkler and hydrant networks in remote factories, mining camps, oil and gas field installations, rural warehouses, and facilities with single utility feed. The pump end is a horizontal split-case double-suction unit, and the engine is a 1800 rpm industrial diesel with radiator cooling, battery ignition, and electronic governor rated for automatic start within 15 seconds of a fire signal.
Table of Contents
ToggleProduct Overview
The complete skid comprises the diesel engine, split-case pump, SAE flexible coupling, guard, base fuel day tank of 250 liters, battery set, exhaust with flexible bellows and muffler, suction and discharge valves, pressure gauges, relief valve, test header, and a dedicated diesel fire pump controller. The controller monitors engine speed, oil pressure, coolant temperature, battery voltage, and suction pressure, and performs weekly automatic exercise runs of 30 minutes under no-flow condition. Remote start is accepted from the fire alarm panel via dry contact, and remote shutdown is accepted from the gas suppression and deluge systems. KITOZER supplies the set with a factory test report showing the hydraulic curve overlaid on the system curve, and an engine power curve confirming full-rated drive at the design point.
Technical Specifications
Pump rated flow 80 L/s equal to 288 cubic meters per hour. Pump rated head 85 meters equal to 0.85 megapascal. Shut-off head 115 meters. Double-suction bronze impeller with wear rings. Inlet DN200 PN16. Outlet DN150 PN16. Pump efficiency at BEP 82 percent. NPSH required 6.0 meters. Diesel engine rated output 110 kilowatt at 1800 rpm, turbocharged, water-cooled, radiator fan. Governor electronic, ISO 8528 class G2. Starting system 24 volt DC dual batteries. Fuel day tank 250 liters with low-level alarm. Exhaust flexible bellows, spark arrestor, muffler. Engine alarm set low oil pressure, high coolant temperature, overspeed 2100 rpm. Controller automatic with weekly exercise, RS485 Modbus, dry contacts for remote start and fault. Baseplate welded steel with drip rim and anchor bolts. Certifications CCCF, ISO 9001, NFPA 20, GB 50974. Warranty 24 months from commissioning.
Application Scenarios
Typical installations include remote manufacturing plants without dual utility feed, mining camps, oil pipeline pump stations, rural warehouse parks, isolated data centers requiring backup beyond UPS and generator, forest-adjacent facilities, and any site where the insurance loss-prevention engineer mandates diesel-driven fire pump capacity. The 80 L/s flow covers extra-hazard sprinkler demand over 2500 square meters plus four hydrant streams of 5 L/s for yard firefighting. The set is commonly paired with an electric jockey pump of 2 L/s to maintain static pressure, and a fuel storage tank of 5 cubic meters to support 8 hours of full-flow run, satisfying the most demanding NFPA 20 engine fuel duration rules.
Advantages and Features
The diesel engine operates independently of the electrical grid, so the pump still runs during a total site power outage. Electronic governor holds speed within one percent from no-flow to full-flow, giving stable pressure across the sprinkler demand range. The controller performs weekly exercise runs, preventing the stale-fuel and seized-engine faults that plague untested diesel sets. The 24 volt dual-battery starting system ensures reliable first-start even after months of standby. The skid is delivered fully aligned, so onsite crews only connect suction, discharge, exhaust, and fuel lines. KITOZER sources the engine from an established industrial diesel brand with worldwide service network, reducing parts lead time for the end user.
Installation and Maintenance Recommendations
Install the set in a dedicated pump room with mechanical ventilation rated for engine air intake and exhaust heat. Maintain ambient temperature above 10 degrees Celsius for reliable cold starting, or install block heater for colder climates. Fuel day tank must be fed from a main storage tank sized for 8 hours of full-flow run. Conduct weekly automatic exercise of 30 minutes no-flow, monthly flow test at the header, and annual full-flow witness. Change engine oil and filter every 250 operating hours or annually. Replace fuel filters every 500 hours. Test battery specific gravity monthly and trickle charger weekly. Inspect exhaust bellows and spark arrestor every six months. Verify cooling fluid concentration annually. Keep a logbook of every run, including duration, oil pressure, coolant temperature, and any alarm. Store spare fuel filter, oil filter, and belt set on site.
Price
From 22,500 US dollars per complete diesel pump skid including engine, pump, baseplate, day tank, batteries, controller, exhaust, valves, and gauges. Contact KITOZER for engine brand selection, fuel storage design, and factory lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com