KITOZER Differential Pressure Bypass Valve DN80 HVAC Chilled Water

The KITOZER DN80 differential pressure bypass valve maintains constant pressure differential between supply and return mains in variable flow chilled water systems. As terminal control valves close at part load, the bypass valve opens to divert excess water back to the return, preventing overpressure and protecting control valves from noise and wear. This mechanical valve requires no external power and provides stable hydronic balancing.

In a two way valve system, the flow through the secondary loop decreases as valves close. If the secondary pump runs at constant speed, differential pressure rises, causing noise in partially open valves and wasting pump energy. The bypass valve opens to absorb the excess flow, keeping differential pressure stable until the VFD pump controller ramps down.

Product Overview

The bypass valve is a diaphragm or piston actuated globe pattern valve with adjustable spring setting. It is installed across the supply and return mains near the end of the distribution loop. The valve modulates automatically in response to pressure differential, opening when differential exceeds setpoint and closing when it drops. A test pressure gauge port and isolation valves allow commissioning and service without draining the loop.

The valve body is cast iron with bronze trim. The diaphragm is EPDM rated for hot and cold water. The adjustable spring sets the cracking pressure from 0.1 to 2.5 bar. The valve is provided with flanged ends for direct mounting between standard flanges. A manual isolation ball valve and drain are recommended on each side.

Technical Specifications

Nominal size DN80 flange PN16. Adjustable pressure differential range 0.1 to 2.5 bar. Maximum flow 80 m3 per h. Cv value 45. Body material cast iron GG25, valve plug brass, diaphragm EPDM. Maximum working pressure 16 bar. Maximum temperature 120 C. Weight 18 kg. CE certified, 2 year warranty.

Application Scenarios

Install the bypass valve between chilled water supply and return mains at the farthest point of the secondary loop. It is essential in systems with two way control valves on air handling units and fan coil units. It also protects primary pumps from dead heading when secondary valves close. The valve is commonly paired with a differential pressure sensor and VFD pump control to complete a variable volume hydronic system.

In heating systems, the bypass valve protects radiators and thermostatic valves from high pressure differential at night setback. In cooling systems, it protects control valves at AHU coils. The valve is sized to pass the minimum flow of the smallest pump, ensuring the pump never dead heads. Multiple bypass valves may be installed in large networks.

Advantages and Features

Mechanical operation requires no electricity or controls, making it reliable in remote plant rooms. The adjustable spring allows field tuning to design differential pressure. The cast iron body with brass internals provides long service in closed water loops. Low noise operation avoids water hammer. The valve can be serviced without removal by replacing the diaphragm and seat. Flanged ends simplify installation and replacement.

Unlike motorized bypass valves, this mechanical valve responds instantly to pressure changes without controller lag. It fails open on spring loss, preventing pump dead heading. The diaphragm design provides modulating action rather than on off, ensuring smooth pressure control. The valve is compatible with glycol solutions and treated water.

Installation and Maintenance

Install the valve vertically with flow direction matching the arrow. Connect pressure sensing lines to supply and return mains with isolation ball valves. Adjust the spring tension during commissioning to design differential pressure. Monitor pressure gauges periodically to confirm stable differential.

Annually inspect diaphragm condition and seat tightness. Replace diaphragm after 5 years or when leakage occurs. Flush the loop before first startup to prevent debris damaging the seat. If the valve chatters, adjust spring tension or check for air in the sensing lines.

The bypass valve is typically sized to pass the minimum stable flow of the smallest pump on the system. This ensures that even when all terminal valves close, the pump still has enough flow to avoid overheating. The valve works in conjunction with a VFD controlled secondary pump that modulates speed to maintain a differential pressure setpoint. The bypass provides an immediate mechanical safety net while the VFD adjusts. This combination of mechanical relief and electronic control is the standard design for modern variable volume hydronic systems.

KITOZER supplies the bypass valve with optional flanged pressure tap connections and isolation ball valves as a kit. The valve is suitable for closed water systems with glycol concentration up to 50 percent. The spring range can be factory set to the design differential pressure before shipment, reducing commissioning time. For large networks, multiple bypass valves can be installed in parallel to handle higher bypass flows. The valve is CE marked and supplied with installation and maintenance instructions.

Price

From $320 per valve. Contact KITOZER for larger sizes and flanged pressure tap kits.