KITOZER Differential Pressure Bypass Valve DN80 HVAC Chilled Water

The KITOZER DN80 differential pressure bypass valve maintains constant pressure differential between supply and return mains in variable flow chilled water systems. As terminal control valves close at part load, the bypass valve opens to divert excess water back to the return, preventing overpressure and protecting control valves from noise and wear. This mechanical valve requires no external power and provides stable hydronic balancing.

Product Overview

The bypass valve is a diaphragm or piston actuated globe pattern valve with adjustable spring setting. It is installed across the supply and return mains near the end of the distribution loop. The valve modulates automatically in response to pressure differential, opening when differential exceeds setpoint and closing when it drops. A test pressure gauge port and isolation valves allow commissioning and service without draining the loop.

Technical Specifications

Nominal size DN80 flange PN16. Adjustable pressure differential range 0.1 to 2.5 bar. Maximum flow 80 m3 per h. Cv value 45. Body material cast iron GG25, valve plug brass, diaphragm EPDM. Maximum working pressure 16 bar. Maximum temperature 120 C. Weight 18 kg. CE certified, 2 year warranty.

Application Scenarios

Install the bypass valve between chilled water supply and return mains at the farthest point of the secondary loop. It is essential in systems with two way control valves on air handling units and fan coil units. It also protects primary pumps from dead heading when secondary valves close. The valve is commonly paired with a differential pressure sensor and VFD pump control to complete a variable volume hydronic system.

Advantages and Features

Mechanical operation requires no electricity or controls, making it reliable in remote plant rooms. The adjustable spring allows field tuning to design differential pressure. The cast iron body with brass internals provides long service in closed water loops. Low noise operation avoids water hammer. The valve can be serviced without removal by replacing the diaphragm and seat. Flanged ends simplify installation and replacement.

Installation and Maintenance

Install the valve vertically with flow direction matching the arrow. Connect pressure sensing lines to supply and return mains with isolation ball valves. Adjust the spring tension during commissioning to design differential pressure. Monitor pressure gauges periodically to confirm stable differential. Annually inspect diaphragm condition and seat tightness. Replace diaphragm after 5 years or when leakage occurs. Flush the loop before first startup to prevent debris damaging the seat.

Price

From $320 per valve. Contact KITOZER for larger sizes and flanged pressure tap kits.