KITOZER Disconnect Switch: 10kV 630A Isolator For Switchgear

The KITOZER 10kV disconnect switch is a mechanical isolating device used to create a visible break in a medium-voltage circuit for safe maintenance and isolation. Unlike a circuit breaker, an isolator is not designed to interrupt load current; it is operated only after the upstream breaker has tripped. Its role is to provide unambiguous electrical separation and a visible open gap so that personnel can work on downstream equipment with confidence. KITOZER builds the isolator with robust porcelain or epoxy supports, silver-plated contacts, and a manual or motorized operating mechanism, making it a standard accessory in 10kV switchgear line-ups, ring main units, and feeder panels.

Technical Specifications

Rated voltage 12kV, rated frequency 50Hz, rated normal current 630A, rated short-time withstand current 20kA for 4 seconds, peak withstand current 50kA, power frequency withstand voltage 42kV, lightning impulse withstand voltage 75kV. Insulation: epoxy resin or porcelain post insulators. Contacts: silver-plated copper. Operating mechanism: manual gang operation or optional motor drive at DC 110V or 220V. Mechanical interlock prevents operation under load and interlocks with associated earthing switch. Conforms to IEC 62271-102 and GB standards.

Applications

The KITOZER 10kV disconnect switch is installed in 10kV indoor switchgear, ring main units, and cable branch boxes. It is used to isolate transformers, feeder cables, metering sections, and bus couplers during maintenance. In industrial plants it separates a faulty feeder from the live bus while crews repair the downstream cable or switchgear. In commercial and hospital substations it provides isolation for the incoming feeder, allowing transformer replacement without shutting down the entire site. It is also paired with load break switches in pole-mounted and kiosk-type distribution equipment to create a fully isolated maintenance point.

The isolator is frequently used together with an earthing switch: when the line is isolated and proven dead, the earth switch closes to discharge capacitive charge and provide a safety earth for working crews. Mechanical and electrical interlocks ensure that the isolator cannot be opened under load, that the earth switch cannot close unless the isolator is open, and that the isolator cannot close while the earth switch is closed. This interlock logic is essential for safe distribution operation.

Key Advantages

The visible blade gap gives maintenance staff immediate visual confirmation that the circuit is isolated, which is difficult to achieve with a sealed breaker alone. The isolator has no arc quenching chamber to service, so its maintenance burden is limited to contact inspection and insulator cleaning. Silver-plated contacts keep contact resistance low and resist oxidation over years of stationary service. KITOZER offers both side-break and center-break configurations to match different switchgear panel layouts, and the operating mechanism can be adapted for front or side operating shafts.

Motorized versions allow remote opening and closing for unmanned substations and distribution automation schemes, with position feedback sent back to the SCADA system. The isolator is mechanically interlocked with the upstream circuit breaker so that operating sequencing is enforced, reducing human error during switching operations. Standardized dimensions allow the isolator to be retrofitted into existing 10kV panels without major structural changes.

Installation and Maintenance

Mount the isolator plumb and level on the switchgear chassis or busbar support structure, ensuring phase spacing meets the design clearances. Align the moving contacts so they seat evenly on the fixed contacts with full contact wipe. Torque all primary connections to the specified value and check the earthing of the frame. Operate the manual handle several times to confirm smooth movement and correct interlock sequence before energizing.

During preventive maintenance, inspect contacts for oxidation or burning, clean insulators, and check the tension of contact fingers. Measure contact resistance to confirm it remains within factory limits. Verify that the mechanical interlock prevents incorrect operation and that auxiliary contacts correctly report open and closed positions to the control system. Lubricate the operating shaft and linkages with the recommended grease, and replace any cracked or tracking insulator immediately. Never attempt to open or close the isolator while load current is flowing.