KITOZER Dry Cooler 600kW For Data Center Free Cooling

The KITOZER 600kW dry cooler is a closed loop air cooled heat exchanger designed to reject process heat directly to ambient air without water consumption. It is widely used in data center secondary loops, outdoor process cooling, generator radiator supplemental cooling, and industrial hydraulic oil cooling where water based cooling towers are not available or water cost is high. The unit is especially valuable in dry climates and for facilities with strict water conservation targets.

The V coil arrangement places two coil banks in a V shape, maximising face area within a compact footprint. EC fans mounted below the coils draw ambient air upward through the fins. The circuit design divides the coil into multiple independent refrigerant or coolant circuits, so a single circuit blockage does not shut down the whole unit. An internal air vent and drain allow complete loop flushing.

Product Overview

KITOZER dry coolers use copper tubes with aluminum louvered fins arranged in V coil configuration. The circuit is divided into multiple rows for optimal refrigerant or coolant distribution. EC axial fans provide variable speed control and low sound. The cabinet is hot dip galvanized steel with polyester powder coating. A drain and vent connection allows complete draining for winter shutdown. An optional internal electric heater prevents freeze damage when the unit is idle in cold climates. The unit arrives pre pressurized with glycol water mix and ready to connect to the process loop.

Optional accessories include a weatherproof fan speed controller with 0 to 10 V input, a glycol make up tank with level switch, and an indoor hydraulic module with circulation pumps. The unit can also be supplied with a stainless steel cabinet for coastal or corrosive industrial atmospheres. Multiple dry coolers can be piped in parallel to scale heat rejection to several MW.

Technical Specifications

Nominal heat rejection 600 kW at 35 C ambient, 40 C inlet, 45 C outlet. Air flow 180,000 m3 per h. Four EC fans, each 1.1 kW, total 4.4 kW. Circuit working pressure 16 bar. Water connection DN100. Coolant 30 percent ethylene glycol. Weight 2800 kg. Dimensions 4500 x 2200 x 2800 mm. Fan speed controlled by 0 to 10 V signal from water temperature sensor. Sound level 62 dB(A) at 10 m. CE certified, 5 year coil warranty.

Application Scenarios

Typical installations include data center rear door heat exchanger loops, backup heat rejection for chiller plants, outdoor cooling for battery energy storage systems, wind turbine converter cooling, laser cutter cooling, and plastic mold temperature control. In temperate climates the dry cooler can provide 100 percent free cooling during winter months, allowing the chiller to shut down entirely and saving substantial energy. It is also used in industrial cooling loops where water treatment and make up are impractical.

In semiconductor fabs, dry coolers serve as the primary heat rejection for process cooling water. In hospitals, they provide emergency backup cooling when the cooling tower is offline for maintenance. In telecom base stations, small dry coolers cool power amplifiers without water consumption. The modular design allows units to be added as IT load grows, avoiding a single oversized upfront investment.

Advantages and Features

Zero water drift and zero water consumption reduce municipal water use and eliminate Legionella risk associated with open cooling towers. EC fans reduce fan energy by 30 percent compared with AC fans. The V coil design maximizes coil face area within a compact footprint. Corrosion resistant coating option is available for coastal or industrial atmospheres. The unit can be installed outdoors without a dedicated plant room, saving building space. Modular arrangement allows multiple units to be paralleled for larger heat rejection duty.

Compared with adiabatic coolers, dry coolers have no water connection, no drift eliminator, and no water treatment. This makes them ideal for remote sites with limited maintenance staffing. The EC fans can be speed controlled by glycol temperature, so fan power tracks load. The coil is factory pressure tested and leak checked before shipment.

Installation and Maintenance

Install the dry cooler on a steel frame or roof curb with adequate clearance for air inlet and outlet. Avoid recirculation of hot exhaust air into the coil. Use flexible hoses on coolant connections. The loop should be filled with treated glycol solution and vented. Commissioning includes verifying fan rotation, EC controller signal, and pressure relief valve setting.

Twice per year, clean the coil with low pressure water or air to remove dust and pollen. Inspect fan motor bearings and vibration isolators. Check electrical connections and heater function before winter. Verify glycol concentration annually and top up with inhibited glycol. Keep a log of ambient temperature, glycol supply, and fan speed to track coil performance over time.

Price

From $9,800 per unit. Contact KITOZER for free cooling integration design and project pricing.