KITOZER Dry Cooler 600kW For Data Center Free Cooling

The KITOZER 600kW dry cooler is a closed loop air cooled heat exchanger designed to reject process heat directly to ambient air without water consumption. It is widely used in data center secondary loops, outdoor process cooling, generator radiator supplemental cooling, and industrial hydraulic oil cooling where water based cooling towers are not available or water cost is high. The unit is especially valuable in dry climates and for facilities with strict water conservation targets.

Product Overview

KITOZER dry coolers use copper tubes with aluminum louvered fins arranged in V coil configuration. The circuit is divided into multiple rows for optimal refrigerant or coolant distribution. EC axial fans provide variable speed control and low sound. The cabinet is hot dip galvanized steel with polyester powder coating. A drain and vent connection allows complete draining for winter shutdown. An optional internal electric heater prevents freeze damage when the unit is idle in cold climates. The unit arrives pre pressurized with glycol water mix and ready to connect to the process loop.

Technical Specifications

Nominal heat rejection 600 kW at 35 C ambient, 40 C inlet, 45 C outlet. Air flow 180,000 m3 per h. Four EC fans, each 1.1 kW, total 4.4 kW. Circuit working pressure 16 bar. Water connection DN100. Coolant 30 percent ethylene glycol. Weight 2800 kg. Dimensions 4500 x 2200 x 2800 mm. Fan speed controlled by 0 to 10 V signal from water temperature sensor. Sound level 62 dB(A) at 10 m. CE certified, 5 year coil warranty.

Application Scenarios

Typical installations include data center rear door heat exchanger loops, backup heat rejection for chiller plants, outdoor cooling for battery energy storage systems, wind turbine converter cooling, laser cutter cooling, and plastic mold temperature control. In temperate climates the dry cooler can provide 100 percent free cooling during winter months, allowing the chiller to shut down entirely and saving substantial energy. It is also used in industrial cooling loops where water treatment and make up are impractical.

Advantages and Features

Zero water drift and zero water consumption reduce municipal water use and eliminate Legionella risk associated with open cooling towers. EC fans reduce fan energy by 30 percent compared with AC fans. The V coil design maximizes coil face area within a compact footprint. Corrosion resistant coating option is available for coastal or industrial atmospheres. The unit can be installed outdoors without a dedicated plant room, saving building space. Modular arrangement allows multiple units to be paralleled for larger heat rejection duty.

Installation and Maintenance

Install the dry cooler on a steel frame or roof curb with adequate clearance for air inlet and outlet. Avoid recirculation of hot exhaust air into the coil. Use flexible hoses on coolant connections. The loop should be filled with treated glycol solution and vented. Commissioning includes verifying fan rotation, EC controller signal, and pressure relief valve setting. Twice per year, clean the coil with low pressure water or air to remove dust and pollen. Inspect fan motor bearings and vibration isolators. Check electrical connections and heater function before winter.

Price

From $9,800 per unit. Contact KITOZER for free cooling integration design and project pricing.