KITOZER Dry Transformer: 1000kVA 10kV/0.4kV Cast Resin

KITOZER 1000kVA cast resin dry type transformer steps 10kV distribution voltage down to 400V for commercial and industrial loads. Because the windings are cast in epoxy resin, the transformer has no oil, no leakage risk, and no fire hazard, making it suitable for indoor installation in occupied buildings, underground substations, and high rise towers. This model offers low no-load loss, low noise, and reliable performance in dusty or damp environments. It is the standard choice for commercial building substations where fire codes prohibit oil filled transformers inside the building footprint.

Product Overview

The transformer consists of silicon steel sheet cores wound with copper foil or copper conductors, encapsulated in vacuum cast epoxy resin. The high voltage winding is wound on the outside and the low voltage winding on the inside, both insulated by resin. Cooling is by natural air (AN) or forced air (AF) with optional fans that raise output by 40 percent. A temperature controller monitors Pt100 sensors embedded in the windings, giving alarm and trip signals at preset temperatures. The enclosure can be IP00 open type or IP21/IP23 sealed for dust protection. The core is cut with step lap joints to reduce no-load loss, and the copper windings are transposed to minimize eddy current loss in the conductors themselves.

Technical Specifications

Rated power 1000kVA, primary voltage 10kV plus or minus 2 times 2.5 percent, secondary voltage 400V, connection Dyn11, impedance 6 percent, frequency 50/60Hz. No-load loss 1770W, load loss 10300W at 120 degrees Celsius, insulation class F or H, temperature rise 100K for class F. Noise level 55dB. Cooling AN or AF, ambient temperature minus 5 to plus 40 degrees Celsius. Enclosure IP21 standard, optional IP23. The temperature controller provides two stage alarm at 130 degrees Celsius and trip at 150 degrees Celsius, with 4 to 20mA output for remote monitoring. Compliance with IEC 60076-11 and GB/T 1094.11. Short time overload capacity is 1.4 times rated for 30 minutes under AN cooling.

Applications

This transformer is used in commercial building substations, shopping malls, hospitals, data centers, and industrial plants where oil transformers are prohibited by fire codes. It is also installed in underground vaults, high rise towers, and offshore platforms where space is limited and leakage would be dangerous. Common secondary loads include LED lighting, HVAC, elevators, UPS, and production machinery. Forced air cooling allows the same unit to supply short time overloads during peak demand. In data centers, the 1000kVA unit typically feeds two 500kVA UPS systems through a low voltage switchboard. In hospitals, the transformer supplies both normal and essential loads through separate switchboards, and the low noise rating is important because substations are often located near patient rooms.

Advantages

No oil means no bunding, no oil testing, and no fire risk, which cuts civil work cost and insurance premium. Epoxy resin windings resist moisture and dust, allowing operation in humid industrial environments. Low no-load loss meets modern efficiency regulations and reduces standby electricity bills. Dyn11 connection suppresses triplen harmonics and provides a stable neutral for single phase loads. Temperature monitoring protects windings from overheating. The unit is recyclable at end of life with minimal environmental impact. Because there is no oil to leak, the transformer can be installed in basement levels without a leakage catch pit, which saves valuable floor area in urban projects.

Installation and Maintenance

Place the transformer on a level, well ventilated plinth with clearance around it for airflow. Connect primary and secondary cables with flexible connectors to avoid mechanical stress on the bushings. Ensure the neutral earthing matches the system design. Commissioning includes insulation resistance, ratio, no-load, and impedance tests before energization. The temperature controller must be calibrated and alarm thresholds verified. Maintenance annually includes cleaning dust from the core and windings with dry compressed air, checking fan operation, and tightening terminals. Inspect the resin surface for cracks every five years. Keep ventilation grilles clear to avoid hot spots. In dusty plants, increase cleaning frequency to twice per year, because accumulated dust on the winding surface reduces cooling and accelerates aging.

When the transformer is installed in a basement switchroom, verify that the ventilation air change rate meets the manufacturer recommendation. Forced air cooling fans should be tested quarterly, and the filter on the fan intake cleaned twice per year. The temperature controller event log should be reviewed annually to confirm that the alarm setpoints have not drifted. If the transformer is expected to run near rated load for long periods, consider installing a low voltage power analyzer to track winding hot spots indirectly through load and ambient temperature.

Ordering and Support

When ordering, specify the kVA rating, primary voltage and tap range, secondary voltage, impedance, enclosure rating, and whether forced air cooling is required. KITOZER supplies the transformer with routine test reports, temperature controller settings, and installation drawings. Spare Pt100 sensors and fan motors are recommended. Technical support covers load flow study, short circuit calculation, and switchroom ventilation design. The transformer is backed by a two year warranty on site and a five year warranty on the windings against manufacturing defects.

Price

From $11,800/pc. Contact +86 13922289957 for transformer pricing.