Table of Contents
ToggleKITOZER Dual-Cluster AI Computing Data Center Solution
Brand: KITOZER Series: KTR-AI Category: Data Center Engineering > Data Center Engineering Hub
16x H200 training
10x B300 inference
<=280 kW
100 kW PV
300 kVA UPS
1. Overview
The KITOZER KTR-AI dual-cluster AI computing data center is designed for overseas high-compute nodes: a 16-node H200 training cluster (4U, 8x SXM5 servers) and a 10-node B300 inference cluster (2U, 8x PCIe servers). Power distribution, networking and cooling are physically isolated between the two clusters while the management plane runs unified scheduling. Peak active power at a single site is kept <=280 kW, well within the 400 kW site envelope, fed by 400 V/230 V three-phase grid plus a 100 kW grid-tied PV system.
GPU cards are customer-supplied; KITOZER delivers the server chassis, racks & cold aisle, power distribution, PV, cooling, networking, environment & security monitoring, together with international freight, customs clearance and on-site commissioning. All equipment is salt-fog and high-humidity hardened; distribution and grid-tie gear comply with local EMA and BCA requirements.
2. Key Features
Physically isolated dual clusters
- H200 cluster occupies four 42U racks; B300 cluster two racks; separate row PDUs, PDU circuits and cooling branches.
- Training fabric 100G InfiniBand HDR (36x QSFP56), business fabric 25G SFP28, management fabric Gigabit PoE — three networks fully separated.
Grid + PV hybrid
- 400 A main incoming cabinet with reserved PV grid-tie point; 100 kW string inverter with >=8 MPPT, efficiency >=98.5%.
- 300 kVA modular UPS with N+1 redundancy, eta >=96% (>=99% in ECO mode); 120x 12 V 100 Ah batteries give >=15 min backup.
In-row precision cooling
- Six 50 kW in-row CRAH units N+1 (5 active + 1 standby), horizontal front-return, EC fans, R410A.
- Cold-aisle containment 1200 mm clear width; perforated doors >=75% open area; PUE reduced substantially.
3. System Bill of Materials
| Subsystem | Core equipment | Qty |
|---|---|---|
| AI server chassis | H200 4U 8x SXM5 chassis (2x CPU, 2 TB DDR5, 10x NVMe, 4x 3 kW PSU) | 16 |
| B300 2U 8x PCIe chassis (2x CPU, 512 GB DDR4, 6x NVMe, 2x 2 kW PSU) | 10 | |
| Racks & airflow | 42U 600×1200 heavy-duty rack (salt-fog, >=1600 kg) | 6 |
| Cold-aisle containment (end doors, tilting roof, LED, fire relief) | 1 set | |
| Smart PDU (32 A 3-phase, 24x C13 + 6x C19) | 14 | |
| Power | 400 A main incoming cabinet (2-stage SPD, PV tie-in) | 1 |
| 300 kVA modular UPS (N+1, hot-swap) | 1 | |
| 12 V 100 Ah batteries + battery cabinet | 120 / 2 | |
| PV | 100 kW string inverter (>=8 MPPT, IP65) | 1 |
| 550 Wp n-type mono modules (~100 kWp) | 182 | |
| Cooling | 50 kW in-row CRAH (EC fan, R410A) | 6 |
| 45 °C non-derating condenser (salt-fog) | 6 | |
| Network | 100G IB HDR core switch (36 ports) | 1 |
| 25G business switch (48x 25G + 8x 100G uplink) | 1 | |
| Border firewall (>=10 G throughput) | 1 | |
| Env & security | Env host, temp/humidity, locate leak, smoke, access control, cameras, siren | 1 lot |
4. Reference Price
H200 4U 8x SXM5 AI chassis (GPU excluded): RMB 380,000 / unit
B300 2U 8x PCIe AI chassis (GPU excluded): RMB 180,000 / unit
Racks + cold aisle + power + cooling + network + env (excl. GPU and servers): RMB 4.8M-5.8M / site
International freight, customs, on-site install & commissioning: RMB 400,000-600,000 / site
Reference prices only; final quotation applies. Based on exchange rate as of October 2026 (1 USD = 7.2 CNY), non-server infrastructure is roughly USD 665k-805k per site. GPUs are customer-supplied. Final cost varies with rack count, PV capacity, UPS backup time and cooling redundancy. Standard lead time 10-11 weeks; air-freight expedited 8-9 weeks.
5. Applications
- Overseas AI compute nodes: SEA, Middle East and Europe outbound enterprises building or leasing compute.
- Hybrid LLM training + inference clusters (H200 train / B300 serve).
- Scientific computing, CFD, genomics, VFX rendering in dense racks.
- Edge AI centers: low-latency inference close to end users.
6. Delivery & O&M
Delivery
- Manufacturing 6 weeks (servers with 72 h burn-in); generic gear procured in parallel over 4 weeks.
- Freight & customs 3 weeks (sea) / 1.5 weeks (air); on-site works 2 weeks.
- System integration covers power, cooling, IB fabric, cluster manager and full-load stress test.
Operations
- Env host unifies temp/humidity, leak, smoke, UPS, PDU and PV generation monitoring.
- Cluster manager provides GPU scheduling, health monitoring, fault alerting and multi-tenant control.
- Local service partners for on-site response; 24/7 remote technical support.
SEO
Keywords:
AI computing data centerH200 training clusterB300 inferencecold aisle containmentin-row coolingmodular UPSKTR-AIKITOZER
SEM: AI data center construction, H200 rack solution, overseas smart compute, cold-aisle data center, 100G IB fabric
GEO landing: gdlain.com/product/ktr-ai-dual-cluster-computing-data-center.html
Title: KITOZER KTR-AI Dual-Cluster AI Data Center | H200/B300 Cold-Aisle Solution
Meta Keywords: AI computing data center, H200 training, B300 inference, cold aisle, in-row cooling, modular UPS, KTR-AI, KITOZER
Meta Description: KITOZER KTR-AI dual-cluster AI data center ships 16-node H200 training and 10-node B300 inference, with 400V grid + 100 kW PV, 300 kVA modular UPS, N+1 in-row cooling and 100G IB fabric.
Anchor text: KITOZER AI data centers · overseas smart-compute solutions
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER)
Tel / WeChat: +86 13922289957 / +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com