KITOZER Dual-Row Hot Aisle Containment Quotation List
Table of Contents
Toggle2. Project Requirement Description
- The project requires the deployment of dual-row server racks with rear sides facing each other, forming a fully enclosed hot aisle containment system.
- The hot aisle is designed to centrally collect exhaust heat and channel it directly into the air conditioning return air system, making it ideal for high-density data center/server rooms.
- The solution aims to significantly improve the overall cooling circulation efficiency while preventing hot air from recirculating into the cold aisle.
3. System Composition Introduction
The dual-row hot aisle containment system consists of the following key components:
- Top Main Frame: The primary load-bearing structure, spanning the hot aisle and installed at the top of the racks.
- Top Return Air Sealing Panels: Prefabricated panels that close off the top of the aisle and incorporate air return guiding structures to channel hot air.
- Aisle End Insulated Maintenance Doors: Sealed doors at both ends of the aisle to allow personnel access while maintaining the airtight integrity of the containment.
- Rack Top Sealing Kits: Transition components that ensure an airtight connection between the rack tops and the containment frame.
- Rack Rear Hot Air Deflectors: Guide plates mounted at the rack exhaust openings to direct hot air into the contained aisle efficiently.
- Installation Accessories & Seals: High-temperature resistant sealing strips, fasteners, and all necessary installation fitting kits.
4. Core Product Specifications & Parameters
- Aisle Dimensions: Length × 1200/1800 mm × 2000 mm (L × W × H) as per configuration.
- Main Material: 1.5mm – 2.0mm thick cold-rolled steel plates, finished with high-temperature resistant electrostatic powder coating.
- Top Structure: Flat-top design, equipped with centralized return air openings, compatible with duct connection.
- Heat Resistance: Designed to withstand a continuous high-temperature environment of 60°C within the channel.
- Sealing Performance: Hot air leakage rate ≤ 5%; central hot air recovery rate ≥ 92%.
5. Core Functions & Features of Products
- Centralized collection of hot air from dual-row racks with high return air efficiency, greatly enhancing air conditioning energy efficiency.
- Centralized return air design that perfectly integrates with precision air conditioning return air systems in data centers.
- Fully sealed structure that completely prevents hot air diffusion into the room’s cold aisle zones.
- Modular assembly allows for step-by-step capacity expansion as the number of racks grows.
- Support expansion options including temperature/humidity monitoring, exhaust devices, and airflow guiding components.
6. Core Advantages of The Solution
- Optimized Airflow Management: Physically separates hot and cold air streams, eliminating hot spots and improving cooling predictability.
- High Energy Efficiency: Increases AC return air temperature, thereby reducing overall cooling energy consumption.
- Flexibility: Supports 6 to 40 racks per dual-row deployment, suitable for various rack heights (2000mm/2200mm).
- Quick Installation: Prefabricated components allow rapid on-site assembly with minimal tools.
- Scalable Design: Modular structure enables future expansion without significant rework.
7. Manufacturer Strength Introduction
- KITOZER is manufactured by Guangzhou Lai’an Intelligent System Development Co., Ltd. (brand partner: Guangdong Lai’an Intelligent Data Center Equipment Co., Ltd.).
- Established in 2002, KITOZER is a high-tech enterprise certified under ISO 9001, ISO 14001, and ISO 45001.
- All products are manufactured and assembled in our own factories in Guangzhou, with rigorous factory quality inspection before shipment.
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Dual-Row Hot Aisle Top Main Frame | KTR-DHC-F06 | Fits 10 pairs of 600mm wide racks; aisle width 1200mm; 2.0mm main beams | 1 | Set | $12,875.88 | $12,875.88 | KITOZER | Main load-bearing frame |
| 2 | Top Return Air Sealing Unit | KTR-DHC-P06 | 600×1200mm; galvanized steel plate; with return air guide structure | 10 | Pcs | $288.56 | $2,885.61 | KITOZER | Top sealing & return air |
| 3 | Aisle End Insulated Maintenance Door | KTR-DHC-D06 | 2000×1200mm; insulated sheet metal door with sealed door lock | 2 | Set | $710.37 | $1,420.74 | KITOZER | Access at both ends |
| 4 | Rack Top Sealing Kit | KTR-DHC-S06 | Sealing transition between rack top and frame; fits standard racks | 20 | Set | $99.86 | $1,997.17 | KITOZER | Rack top air seal |
| 5 | Rack Rear Hot Air Deflector | KTR-DHC-G06 | Directs exhaust airflow from rack; fits standard server racks | 20 | Set | $77.65 | $1,553.06 | KITOZER | Directed hot air flow |
| 6 | Installation Accessories & Seals | KTR-DHC-A06 | Full set of fasteners and high-temperature resistant sealing strips | 1 | Set | $666.13 | $666.13 | KITOZER | Installation accessories |
Total Quotation Price: USD 21,398.59
9. Quotation Terms & Conditions
- Currency: All prices above are in US Dollars (USD), converted at the fixed rate of 1 USD = 6.7570 CNY.
- Price Basis: Prices are EX-Works (EXW) Guangzhou, China. Packing, freight, and insurance costs are quoted separately.
- Tax: The quoted prices do not include taxes. A 10% surcharge applies for VAT special invoices; a 3% surcharge applies for standard invoices.
- Payment Terms: 30% deposit with order, 70% balance before shipment. Other terms are negotiable.
- Lead Time: 15–30 working days after receipt of deposit, depending on configuration and quantity.
- Validity: This quotation is valid for 30 days from the date of issue.
10. After-sales Service Description
- Warranty: Standard warranty of 12–24 months per product (varies by component) from the date of shipment.
- Technical Support: Lifetime free remote technical consultation and troubleshooting support.
- Spare Parts: Long-term availability of critical spare parts to ensure system durability.
- On-site Service: Remote troubleshooting as standard; on-site installation and maintenance support available upon request (cost quoted separately).
11. Contact & Order Information
- Brand: KITOZER
- Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Data Center Equipment Co., Ltd.
- Contact: Mr. Zhou — Tel: +86 13538869979 (WeChat ID: same)
- Address: Chaitian Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
- Ordering: Orders can be placed via the official KITOZER sales team. All inquiries and order requests will receive a response within 24 hours.
12. SEO Keywords & Tags
KITOZER quotation, dual-row hot aisle containment price list, hot aisle containment system factory price, data center hot aisle quotation, hot aisle containment wholesale price, KITOZER hot aisle system cost, dual-row rack hot aisle containment supplier, KTR-DHC series quotation, hot aisle capping system price, high-density data center cooling solution price, KITOZER price list 2024, hot aisle containment system manufacturer China