KITOZER
KITOZER

KITOZER duct mount temp humidity sensor

KITOZER KTR-TH6 Duct Temperature & Humidity Sensor

Brand:KITOZER Series:KTR-TH6 Category:Environmental Monitoring / Temp-humidity

Duct mountTemp+RHRS485EM monitoring

[Product image: ktr-th6-duct-temperature-humidity-sensor.jpg]

1. Overview

Temperature and humidity are the two most basic yet important parameters in room EM monitoring. High temperature triggers server throttling alarms; high humidity causes condensation shorts; low humidity causes ESD that chips components. A wall sensor measures return-air room air, but the supply-air duct’s actual air temperature and humidity are the direct feedback to the AC. A duct sensor probes into the supply/return duct, measures air T and RH in real time, and sends RS485 or 4-20mA to the EM platform or AC controller, closing the loop: if supply air is too warm, the AC ramps cooling; if too dry, the humidifier adds moisture.

The KTR-TH6 is a duct temp/RH sensor with probe lengths of 150-300 mm, inserted into the duct and fixed by a flange plate. The sensing element is a capacitive RH sensor plus NTC temperature sensor. Temperature range -40 to +80 C, accuracy +/-0.5 C; RH range 0-100%, accuracy +/-3%. Output is RS485 Modbus-RTU or two-channel 4-20 mA loop, powered by DC12-24V. ABS flame-retardant housing, IP54 (probe IP65). Used on precision AC supply/return ducts, fresh air and exhaust ducts; it is the front-end pickup for AC group control and EM monitoring.

Selection considers range and accuracy, output (RS485/4-20mA/0-10V), probe length (by duct wall thickness), mounting (duct/wall/channel) and supply voltage. Rooms usually use RS485 to the EM platform; +/-0.5 C and +/-3% RH is enough. Industrial harsh environments choose higher accuracy and protection. The probe must reach the duct center, not touch the wall – wall contact reads metal temperature, not air.

2. Key Features

Measurement

  • Temp -40 to +80 C, +/-0.5 C.
  • RH 0-100%, +/-3% RH.
  • Capacitive RH sensor, fast response.
  • NTC temp, long-term stable.

Output & power

  • RS485 Modbus-RTU.
  • Optional dual 4-20 mA loop.
  • DC12-24V wide supply.
  • Baud 9600/19200 selectable.

Structure & mount

  • Probe 150/200/300 mm options.
  • Flange plate fixes to duct.
  • ABS housing, IP54.
  • Probe head IP65 moisture-proof.

3. Specifications

Item KTR-TH6 Duct Sensor
Temp range -40 to +80 C
Temp accuracy +/-0.5 C
RH range 0-100% RH
RH accuracy +/-3% RH
Output RS485 Modbus-RTU / 4-20mA
Power DC12-24V
Probe length 150 / 200 / 300 mm
Mounting Duct insertion, flange
Protection Housing IP54 / probe IP65
Response <=15 s (at 2 m/s airflow)

4. Reference Prices

KTR-TH6 duct sensor (RS485): Reference USD 25~44 (ref. CNY 180~320 at ~7.2)

KTR-TH6 duct sensor (4-20mA): Reference USD 31~53 (ref. CNY 220~380 at ~7.2)

Reference only; final quote applies. 1-year warranty. Probe length by duct wall. RS485 and 4-20mA priced differently. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Precision AC supply/return duct measurement.
  • Fresh air and exhaust duct monitoring.
  • Room EM monitoring T/RH pickup.
  • AC group control closed loop.
  • Lab and cleanroom duct air checks.

6. Installation & Maintenance

Installation

  • Drill a 16-22 mm hole in the duct.
  • Insert probe to duct center; fix flange.
  • Wire DC12-24V and RS485 A/B.
  • Add sensor on EM platform; set Modbus address.
  • Calibrate against a reference T/RH meter.

Maintenance

  • Brush probe dust with a soft brush.
  • Calibrate RH yearly with saturated salt solution.
  • Seal the duct hole to prevent air leakage.
  • Add 120-ohm terminator at the RS485 bus end.
  • Wait for probe to dry after condensation before reading.

7. FAQ

  • Q: Duct vs wall sensor?
    A: Duct probes into the duct for AC closed-loop control; wall mounts on the wall for room air monitoring. Different positions and uses.
  • Q: How many sensors per RS485 bus?
    A: Theoretically 32 per bus (128/256 with repeaters), each with a unique Modbus address. Rooms usually need only a dozen.
  • Q: RH reading off?
    A: Check probe dirt or condensation first; then calibrate with saturated salt (e.g. NaCl = 75% RH); replace the RH element if offset remains.
  • Q: How deep should the probe go?
    A: Reach the duct center; not the wall. 150-200 mm usually; use 300 mm for large ducts.

8. Trend & Selection

Room EM monitoring trends to IoT, high accuracy and multi-parameter integration; T/RH sensors are the most basic pickups. Choose duct-mounted at duct center; RS485 to EM; +/-0.5 C / +/-3% RH; probe length by duct; calibrate periodically. It is the sense organ of AC closed-loop control.

9. Delivery & Service

KITOZER supplies KTR-TH6 sensors, optionally bundled with RS485 converters, EM hosts, duct flanges and shielded signal cable. Delivery includes sensor, flange, manual, certificate and warranty card. We can produce a sensor-point list from your AC duct layout.

10. Notes

A common pitfall is mounting the probe against the duct wall. Wall contact reads sheet-metal temperature, skewed hot in summer and cold in winter – not real air temperature. Extend the probe to the duct center.

Another pitfall is omitting the RS485 terminator. Without a 120-ohm resistor at both bus ends, signal reflection causes unstable communication. Always add it on long buses.

Selection summary: duct-mounted; RS485/4-20mA; +/-0.5 C / +/-3% RH; probe at duct center; calibrate periodically; 120-ohm terminator. It is the sense organ of AC closed loop.

Systemically, AC group control relies on sensor feedback to close the loop. Bad supply-air readings make the AC regulate poorly, leaving room temperature to swing and servers to run unstable.

Reliability-wise, the sensor is cheap but critical. One failed sensor and the EM platform shows “normal” while the room overheats; by the time servers alarm, it is too late. Periodic calibration and redundant points matter.

SEO Information

Search keywords:KITOZER

SEM keywords:duct temp humidity sensor, duct humidity transmitter, data center temp sensor, RS485 T/RH, KTR-TH6, KITOZER

GEO landing page:lain.com.cn/product/415-temp-hum-6.html

Title:KITOZER KTR-TH6 Duct Temperature & Humidity Sensor

Meta Keywords:duct temp humidity sensor, duct humidity transmitter, data center temp sensor, RS485 sensor, KTR-TH6, KITOZER

Meta Description:KITOZER KTR-TH6 duct temperature humidity sensor, probes into duct, RS485/4-20mA output, accuracy +/-0.5C / +/-3%RH, for room AC duct and EM monitoring.

Anchor: KITOZER by Guangzhou Laian · KITOZER products

Contact Us

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Shopping Cart