The KITOZER outdoor edge computing cabinet brings server-class compute capacity to street level, factory floor, and remote sites where a traditional data center room is unavailable. It houses ruggedized servers, PoE switches, storage, and UPS in a single IP55 enclosure with 3 kW of dedicated cooling and remote lights-out management. The cabinet is engineered for low-latency 5G edge, video analytics, industrial control, and smart city applications. Compared with forcing servers into a passive sealed box, the KITOZER cabinet delivers precision cooling matched to server heat loads, extending equipment life and preventing thermal throttling.
Table of Contents
ToggleProduct Overview
The cabinet provides 18U to 24U of 19 inch rack space, with a front service door and rear cable access. A vertical or side-mounted 3 kW outdoor air conditioner maintains a 25 degree Celsius internal setpoint even under full server load and 55 degree Celsius external ambient. The interior includes hot aisle containment with baffles, cable management arms, and a PDU with metered outlets. Optional battery bay supports 15 to 30 minutes of ride-through for graceful shutdown. A separate equipment compartment houses the UPS and distribution away from server air flow.
Technical Specifications
Ingress protection IP55. Material 1.5mm galvanized steel, outdoor powder coat. Rack space 18U to 24U. Cooling: 3 kW outdoor air conditioner with redundant fans, N plus 1 configuration. Power input: 220VAC single phase or 400V three phase, 32A, with UPS option. PDU: 12 outlets per branch, metered per outlet. Monitoring: cabinet temperature, inlet exhaust differential, door contact, smoke, water leak, power quality, via SNMP and 4G. Operating range minus 30 degrees Celsius to plus 55 degrees Celsius. Dimensions 600mm W by 1000mm D by 1600mm H. KITOZER 5 year enclosure, 2 year AC warranty.
Applications
The cabinet supports 5G multi-access edge computing, traffic intersection video analytics, retail in-store edge servers, factory floor SCADA and historians, railway wayside edge processing, port container OCR systems, and smart city camera video inference. It also serves remote mining and oilfield edge processing where fiber backhaul is limited. The cabinet is frequently used as a street-level compute node for autonomous vehicle sensor fusion and traffic signal adaptive control.
Advantages and Features
Outdoor-rated enclosure removes the need to build or rent an equipment room. Dedicated 3 kW cooling handles dense server loads without hot spots. Hot aisle containment improves cooling efficiency and reduces fan energy. Metered PDU supports per-outlet power management and capacity planning. Lights-out monitoring and 4G remote management allow central NOC control of distributed edge sites. UPS ride-through protects servers from short outages and enables graceful shutdown on long outages. The cabinet also supports remote power cycling of hung servers via metered PDU outlet control.
Installation and Maintenance Recommendations
Place on a level concrete plinth with proper drainage. Leave 600mm clearance at front and rear for service. Seal cable entries and earth the cabinet to site ground. Verify server inlet temperature within manufacturer range during commissioning. Schedule quarterly inspection of AC filters, condenser coils, and door gaskets. Test UPS battery annually. Update server firmware during maintenance windows and keep service spares on hand for remote sites. Monitor hot aisle temperature differential as an early warning of cooling performance degradation.
Customization and Quality
KITOZER offers 5 kW cooling upgrade, liquid cooling option, server pre-integration, and longer UPS runtime. Every cabinet passes a factory thermal load test with dummy loads, insulation test, and AC performance verification before shipment. Units ship with DCIM software license, wiring diagrams, and commissioning manual. Project customers receive thermal modeling support for server load planning.
Working Principle and Design Detail
The cabinet operates as a sealed thermal and electrical island: incoming AC power passes through the input breaker and surge arrester before reaching the internal distribution bus, while the climate controller continuously compares internal air temperature against the setpoint and switches fans or compressor on demand. The door gasket is compressed by multi-point latches to maintain the rated ingress protection across the full door perimeter, and all cable entries use rated glands so that no unsealed opening remains. Internal cable managers route power, signal, and fiber cables on separate paths to prevent electromagnetic interference and simplify tracing during maintenance. The grounding busbar bonds the cabinet frame, internal equipment chassis, and external surge protection to a single equipotential network, reducing touch voltage risk during fault conditions. This structured design ensures that every field-installed connection remains serviceable for the full service life of the enclosure.
Quality and Certification
Every enclosure is manufactured under a documented quality system that includes incoming material inspection, in-process welding and coating checks, and a final factory acceptance test before shipment. Test records cover insulation resistance, continuity, ingress protection verification, and thermal function. Standard certifications include CE marking where applicable, and the enclosure is constructed from materials that comply with RoHS directives. The cabinet is packaged in foam-lined seaworthy crates suitable for long-haul ocean freight, with desiccant bags to prevent transit condensation. KITOZER supports long-term spare parts availability and offers extended warranty options for mission-critical deployments.
Price
From $5,600 per unit including 3 kW AC and metered PDU. Contact KITOZER for server pre-integration and UPS runtime options.