The KITOZER outdoor edge computing cabinet brings server-class compute capacity to street level, factory floor, and remote sites where a traditional data center room is unavailable. It houses ruggedized servers, PoE switches, storage, and UPS in a single IP55 enclosure with 3 kW of dedicated cooling and remote lights-out management. The cabinet is engineered for low-latency 5G edge, video analytics, industrial control, and smart city applications.
Table of Contents
ToggleProduct Overview
The cabinet provides 18U to 24U of 19 inch rack space, with a front service door and rear cable access. A vertical or side-mounted 3 kW outdoor air conditioner maintains a 25 degree Celsius internal setpoint even under full server load and 55 degree Celsius external ambient. The interior includes hot aisle containment with baffles, cable management arms, and a PDU with metered outlets. Optional battery bay supports 15 to 30 minutes of ride-through for graceful shutdown.
Technical Specifications
Ingress protection IP55. Material 1.5mm galvanized steel, outdoor powder coat. Rack space 18U to 24U. Cooling: 3 kW outdoor air conditioner with redundant fans, N plus 1 configuration. Power input: 220VAC single phase or 400V three phase, 32A, with UPS option. PDU: 12 outlets per branch, metered per outlet. Monitoring: cabinet temperature, inlet exhaust differential, door contact, smoke, water leak, power quality, via SNMP and 4G. Operating range minus 30 degrees Celsius to plus 55 degrees Celsius. Dimensions 600mm W by 1000mm D by 1600mm H. KITOZER 5 year enclosure, 2 year AC warranty.
Applications
The cabinet supports 5G multi-access edge computing, traffic intersection video analytics, retail in-store edge servers, factory floor SCADA and historians, railway wayside edge processing, port container OCR systems, and smart city camera AI inference. It also serves remote mining and oilfield edge processing where fiber backhaul is limited.
Advantages and Features
Outdoor-rated enclosure removes the need to build or rent an equipment room. Dedicated 3 kW cooling handles dense server loads without hot spots. Hot aisle containment improves cooling efficiency and reduces fan energy. Metered PDU supports per-outlet power management and capacity planning. Lights-out monitoring and 4G remote management allow central NOC control of distributed edge sites. UPS ride-through protects servers from short outages and enables graceful shutdown on long outages.
Installation and Maintenance Recommendations
Place on a level concrete plinth with proper drainage. Leave 600mm clearance at front and rear for service. Seal cable entries and earth the cabinet to site ground. Verify server inlet temperature within manufacturer range during commissioning. Schedule quarterly inspection of AC filters, condenser coils, and door gaskets. Test UPS battery annually. Update server firmware during maintenance windows and keep service spares on hand for remote sites.
Price
From $5,600 per unit including 3 kW AC and metered PDU. Contact KITOZER for server pre-integration and UPS runtime options.