Table of Contents
ToggleProduct Overview
The KITOZER DN50 electric control valve combines a globe-style valve body with an electric modulating actuator to regulate flow, pressure, or temperature in HVAC and process loops. The actuator accepts a 4 to 20 mA control signal and drives the valve plug to the corresponding position, with feedback that reports actual stem position to the PLC. A fail-safe spring return option closes or opens the valve on power loss, which protects heating and cooling coils during utility outages. The valve is used where compressed air is unavailable or where precise control is required without a separate pneumatic station.
Technical Specifications
Size DN50, flange PN16. Body cast iron or stainless. Trim equal percentage. Flow characteristic Cv 40. Actuator input 4 to 20 mA, feedback 4 to 20 mA. Power 24 VAC/DC or 230 VAC. Running time 15 s to 60 s depending on size. Protection IP67. Ambient -10 to 60 C. Fail spring return optional. CE, KITOZER, 3 year warranty.
Applications
This electric control valve is installed on heating and cooling coils in AHUs, on heat exchanger bypass lines, on steam temperature control in small process skids, and on water mixing stations. In districts where compressed air is not available, the electric actuator replaces pneumatic control valves and eliminates the need for a dedicated air compressor. In clean rooms, the quiet actuator avoids the noise associated with pneumatic vents. In energy retrofit projects, the modulating valve lets building management modulate coil output based on load, reducing pumping and chiller energy.
Advantages
Electric actuation removes the cost, maintenance, and audible noise of compressed air systems, making the valve suitable for quiet offices and hospitals. The 4 to 20 mA control and feedback loop allows the PLC to verify valve movement and detect stuck-stem faults, which is important in safety-related loops. The fail-safe spring return option provides a known position on power loss, protecting coils from over-temperature. The actuator accepts universal power, so a single model works on 24 V and 230 V systems, reducing spare parts. The ball or trim can be changed without removing the actuator from the line.
Installation and Maintenance
Install the valve with the flow direction arrow pointing in the direction of process flow, and mount the actuator above the valve to protect it from pipe condensation. Leave clearance for manual operation and electrical conduit. Use a strainer upstream to protect the trim from debris, and install bypass piping so the valve can be serviced without shutting down the loop. During commissioning, stroke the valve from 0 to 100% and compare the feedback signal with the command. Periodically exercise the valve through its full travel quarterly to prevent sticking. Lubricate stem packing only according to the manufacturer manual, and replace the packing if leakage appears.
Working Principle
The actuator receives a 4 to 20 mA control signal from the PLC and drives an internal gearmotor that moves the stem to the corresponding position. A potentiometer or Hall sensor on the stem feeds back actual position, and the controller compares command and feedback to close the position loop. The equal percentage trim provides non-linear flow characteristics that compensate for non-linear valve characteristics in the loop. On power loss, the spring return option drives the valve to the predefined safe open or closed position.
Selection Guide
Choose the Cv rating so the valve travels at 60 to 80 percent open at design flow. For steam service, select the stainless trim and PN40 rating. For water HVAC, the cast iron body and PN16 are sufficient. For fail-safe applications, choose the spring return version and specify fail open or fail closed. For quiet operation, select the modulating actuator with internal damping. For explosive atmospheres, choose the intrinsically safe certified actuator.
Each valve ships with a quick-start guide, a gasket set, and a mounting nut. Optional accessories include a position feedback board, a handwheel override, and a steam jacket. KITOZER provides pre-sized valves for common Cv values, which arrive ready to install. Spare packing and seal kits are stocked regionally, and a 3 year warranty covers manufacturing defects. Technical support is available by email and WeChat during working hours, and custom sizes or special materials can be ordered with a short lead time. The installation manual includes wiring diagrams and mounting dimensions for common pipe and cabinet configurations, and engineers can request a loop check sheet for commissioning. The device is compatible with common PLC and DCS systems, and Modbus or HART options allow direct integration into SCADA without additional converters. Long-term spare parts availability is guaranteed for at least 10 years after product discontinuation.
Every actuator is factory tested for stroke and leakage before shipment.Price
From $385/pc. Contact +86 13922289957 for electric control valve pricing and Cv selection.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com