KITOZER
KITOZER

KITOZER Electric Fire Pump: 100L/s 1.2MPa For Large Warehouses

KITOZER electric fire pump model EP-100-12 is a heavy-duty double-suction split-case centrifugal pump driving high-capacity sprinkler and hydrant networks in large warehouses, logistics hubs, aircraft hangars, and power plant auxiliary systems. The pump delivers a rated flow of 100 liters per second at a discharge pressure of 1.20 megapascal, sized for ESFR and early-suppression fast-response sprinkler systems covering high-piled storage. The casing is fabricated from high-grade cast iron rated for 2.5 megapascal test pressure, with a bronze double-suction impeller and a stainless steel shaft fitted with replaceable wear rings. The motor is a low-speed, high-slip design optimized for fire pump duty per NFPA 20, ensuring stable operation even at the far right of the curve.

Product Overview

The EP-100-12 skid includes the pump, motor, flexible coupling, full guard, suction and discharge butterfly valves, pressure gauges, relief valve, test header with venturi flowmeter, and a dedicated fire pump control panel with bypass manual starter. The control panel applies primary-resistor or autotransformer reduced-voltage starting to limit inrush, and includes a 24 volt DC battery trickle charger for remote start signals during main power failure. The panel communicates via Modbus TCP with the building fire alarm and BMS, reporting running status, suction and discharge pressure, tank level, and fault codes. KITOZER supplies the set with a hydraulic test curve, vibration report, and insulation resistance test record, so the authority having jurisdiction can accept the installation without additional factory witness unless requested.

Technical Specifications

Rated flow 100 L/s equal to 360 cubic meters per hour. Rated head 120 meters equal to 1.20 megapascal. Shut-off head 150 meters. Double-suction closed impeller, bronze, with wear rings. Inlet flange DN250 PN16. Outlet flange DN200 PN16. Motor power 160 kilowatt, 380 volt three phase, 50 hertz, service factor 1.15. Speed 1480 rpm for low-noise duty. Mechanical seal double acting with external flush. Pump efficiency at BEP 84 percent. NPSH required 6.5 meters. Baseplate heavy fabricated steel with drip rim, grout holes, and anchor bolts. Motor IP55 Class F. Suction and discharge pressure gauges 0 to 2.5 megapascal glycerin filled. Relief valve set at 1.1 times rated head. Test header DN150 with calibrated venturi. Control panel autotransformer start, IP42, with bypass manual starter, battery charger, Modbus TCP, and dry contacts. Certifications CCCF, ISO 9001, NFPA 20, GB 50974. Warranty 24 months from commissioning.

Application Scenarios

This pump is specified for high-piled storage warehouses over 12 meters ceiling, cold storage with ESFR sprinklers, aircraft hangars with foam monitor systems, distribution centers with rack storage, power plant firewater rings, petrochemical tank farm dikes, and large exhibition halls. The 100 L/s flow covers ESFR design demand of 30 to 45 millimeters per minute over 4000 square meters, plus six hydrant streams of 5 L/s each for yard firefighting. Insurance loss-prevention engineers commonly require an identical diesel pump as backup, and KITOZER supplies matched diesel sets on the same baseplate footprint for interchangeability. Consultants select this model when the most remote sprinkler needs 0.35 megapascal residual pressure at the head and the highest-floor hydrant still reaches 0.50 megapascal.

Advantages and Features

The low 1480 rpm speed reduces turbulence, cavitation risk, and noise, extending seal and bearing life over the twenty-year design horizon. The double-suction impeller balances axial thrust, eliminating the bearing loading that shortens single-suction pump life in high-flow duty. KITOZER oversize the casing pressure rating, providing margin for relief valve operation and water hammer during sudden valve closure. The control panel includes a fully manual bypass starter, so the pump can be run even if the automatic logic fails, a safety feature required by most fire authorities. The skid is delivered with all interconnecting piping and wiring pre-installed, reducing field labor by several days. The bronze impeller and replaceable wear rings keep efficiency high over decades of standby service.

Installation and Maintenance Recommendations

Install on a reinforced concrete foundation at least three times the pump shipping weight, with anchor bolts grouted after rough alignment. The suction pipe must be straight for at least five diameters and free of high spots that trap air. Maintain a minimum water level in the suction tank per the NPSH calculation, and install a vortex breaker at the tank outlet. Ventilate the pump room for 160 kilowatt motor heat dissipation, typically 30 kilowatt of heat to remove. Conduct weekly no-flow automatic start, monthly flow test at the header, and annual full-flow witness test. Inspect suction strainer monthly and clean as required. Grease motor bearings every 20,000 hours per the nameplate. Verify relief valve lift annually. Test the battery charger and battery bank quarterly to ensure remote start reliability. Keep the logbook current with every run, including pressure, duration, ambient temperature, and any alarm. Replace the mechanical seal when weepage exceeds one drop per second, and always replace wear rings when the pump is opened for major service.

Price

From 16,500 US dollars per complete pump set including motor, baseplate, valves, gauges, venturi flowmeter, and starter panel. Contact KITOZER for curve selection, ESFR system compatibility check, and factory lead time.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart