KITOZER electric fire pump model EP-30-07 is a horizontal split-case centrifugal unit driven by a three-phase induction motor, purpose-built to supply pressurized water to automatic sprinkler and indoor hydrant networks in mid-rise commercial buildings. The pump delivers a rated flow of 30 liters per second at a discharge pressure of 0.70 megapascal, covering podium retail, office towers up to sixteen floors, light industrial workshops, and mixed-use residential podiums. The wet end is constructed from cast iron with a bronze impeller and stainless steel shaft sleeve, providing robust corrosion resistance against typical municipal water quality while meeting NFPA 20 and GB 50974 construction tolerances. The motor is a Class F insulated, IP55 weatherproof unit rated for continuous duty, mounted on a common steel baseplate with flexible coupling and a shaft misalignment guard. The complete set is delivered as a factory-tested skid with suction and discharge pressure gauges, relief valve, test header, and drain valve, ready for onsite piping connection.
Table of Contents
ToggleProduct Overview
The EP-30-07 follows the end-suction split-case design favored by fire protection engineers because it allows impeller and mechanical seal inspection without disturbing motor alignment or piping. KITOZER engineers select the operating point on the pump curve at eighty percent of the closed-off head, ensuring stable operation across the full sprinkler demand range from hose streams to maximum orifice discharge. The primed suction condition is maintained by a jockey pump and pressure tank, so the fire pump can reach rated pressure within the required ten to fifteen seconds after a fire control panel demand signal. The control panel includes star-delta starting, overload and short-circuit protection, remote start contacts, running indicator lamps, and an RS485 Modbus port for integration with the building fire alarm and BMS systems.
Technical Specifications
Rated flow 30 L/s equal to 108 cubic meters per hour. Rated head 70 meters equal to 0.70 megapascal. Shut-off head 98 meters. Impeller diameter 340 millimeters bronze adjustable. Inlet flange DN150 PN16. Outlet flange DN100 PN16. Motor power 45 kilowatt, 380 volt three phase, 50 hertz. Synchronous speed 2950 rpm. Shaft seal single mechanical seal carbon versus silicon carbide. Pump efficiency at best efficiency point 78 percent. NPSH required 4.2 meters. Baseplate common fabricated steel with drip rim and anchor bolt holes. Motor enclosure IP55, insulation Class F, service factor 1.15. Suction and discharge pressure gauges 0 to 1.6 megapascal with snubber. Relief valve set at 1.05 times rated head. Test header DN65 with flow meter option. Certifications CCCF fire product, ISO 9001, compliant with NFPA 20 and GB 50974. Warranty 24 months from commissioning or 30 months from shipment.
Application Scenarios
This pump is typically installed in the basement fire pump room of mid-rise office towers, shopping malls, hotel podiums, hospital outpatient buildings, light manufacturing workshops, and underground parking structures. It pairs with a jockey pump of around 1 L/s to maintain static pressure on the sprinkler riser, and a diesel backup pump of matching head when the loss of power is a concern. The 30 L/s capacity is sized for sprinkler design densities of 8 to 12 liters per minute per square meter over hazard areas of 1500 to 2500 square meters, plus residual flow for two indoor hydrant hose streams. Architects and MEP consultants specify this model when the highest floor sprinkler head still requires at least 0.10 megapascal residual pressure and the hydrant nozzle pressure must remain above 0.25 megapascal.
Advantages and Features
The split-case wet end allows inspection and seal replacement without pulling the motor or disconnecting suction piping, a major advantage during annual testing. The bronze impeller and stainless sleeve resist pitting from long-term standby wetting, reducing maintenance over the twenty-year design life. KITOZER matches the pump curve to the system curve during shop test, guaranteeing that the rated point falls on the published curve instead of being an approximate selection. The control panel is pre-wired and factory tested with an insulation resistance report, so onsite commissioning is limited to wiring verification and a two-hour flow test. The common baseplate eliminates field alignment errors that cause early bearing failure. The package includes all flanges, gaskets, bolts, and pressure gauges, reducing procurement lead time for the MEP contractor.
Installation and Maintenance Recommendations
Install the pump on a reinforced concrete foundation at least 150 millimeters thick, with anchor bolts grouted after rough alignment. Keep suction piping straight for at least five pipe diameters before the inlet, and avoid air pockets that cause cavitation. The pump room must maintain ambient temperature between 5 and 40 degrees Celsius and be ventilated for motor heat dissipation. Conduct weekly no-flow starting to exercise the motor and verify pressure rise, monthly flow test at the test header, and annual full-flow witness test with the fire authority. Lubricate the motor bearings according to the nameplate interval, typically 20,000 operating hours. Inspect the mechanical seal for weepage at each annual test; a slight weep is normal, but continuous dripping indicates seal replacement. Keep the suction strainer clean and verify that the jockey pump cut-in and cut-out pressures are set at 0.05 and 0.10 megapascal below the fire pump start threshold.
Price
From 4,800 US dollars per complete pump set including motor, baseplate, coupling guard, pressure gauges, and starter panel. Contact the KITOZER engineering team at the number below for a tailored quotation, curve selection, and factory lead time.