KITOZER electric fire pump model EP-60-10 is a double-suction horizontal split-case centrifugal pump driven by a high-efficiency three-phase motor, engineered to feed sprinkler, foam, and hydrant systems in heavy industrial plants, logistics warehouses, and large commercial complexes. The unit delivers a rated flow of 60 liters per second at a discharge pressure of 1.00 megapascal, sized for extra-hazard sprinkler densities and simultaneous hydrant demands. The double-suction impeller halves the hydraulic thrust, allowing longer bearing life and quieter operation than single-suction alternatives. The casing is graded grey cast iron rated for 1.6 megapascal working pressure, with drain plugs and vent cocks at high and low points for complete winter draining.
Table of Contents
ToggleProduct Overview
The EP-60-10 is supplied as a fully aligned skid comprising pump, motor, flexible coupling, guard, suction and discharge valves, pressure gauges, relief valve, test header, and a dedicated fire pump control panel. The control panel applies reduced-voltage star-delta starting to limit inrush current to 3 to 4 times full-load current, protecting the plant transformer and avoiding voltage dips on adjacent production equipment. The panel includes phase-loss and phase-sequence protection, undervoltage shutdown, battery-backed remote start input, running and fault annunciation lamps, and a 4 to 20 milliamp pressure transmitter feeding the BMS. KITOZER ships each pump with a factory hydraulic test curve overlaid on the selected system curve, so the fire engineer can confirm the operating point before installation.
Technical Specifications
Rated flow 60 L/s equal to 216 cubic meters per hour. Rated head 100 meters equal to 1.00 megapascal. Shut-off head 135 meters. Double-suction closed impeller cast bronze. Inlet flange DN200 PN16. Outlet flange DN150 PN16. Motor power 90 kilowatt, 380 volt three phase, 50 hertz, service factor 1.15. Speed 2950 rpm. Mechanical seal double acting with flush plan 11. Pump efficiency at BEP 82 percent. NPSH required 5.8 meters. Baseplate welded steel with drip rim, grout holes, and anchor bolts. Motor IP55 Class F. Suction and discharge pressure gauges 0 to 2.5 megapascal with glycerin fill. Relief valve set at 1.1 times rated head. Test header DN100 with calibrated venturi flowmeter. Control panel star-delta, IP42, with RS485 Modbus and dry contacts. Certifications CCCF, ISO 9001, NFPA 20, GB 50974. Warranty 24 months from commissioning.
Application Scenarios
Typical installations include automotive manufacturing workshops, paint booths with foam sprinkler, paper and textile warehouses, cold storage facilities, power plants auxiliary water systems, petrochemical tank dikes with monitor nozzles, and large distribution centers with ESFR sprinklers. The 60 L/s flow accommodates extra-hazard group 1 sprinkler demand over 3000 square meters, plus four hydrant hose streams of 5 L/s each for factory yard firefighting. When paired with a diesel backup pump of equal capacity, the set satisfies the most demanding insurance loss-prevention requirements for high-piled storage and flammable liquid handling areas. MEP consultants select this model when the most remote hydrant requires 0.35 megapascal residual pressure and the highest sprinkler riser requires 0.15 megapascal at the head.
Advantages and Features
The double-suction impeller balances axial thrust, extending bearing life beyond 50,000 hours of standby operation. The split casing allows impeller inspection without disturbing suction or discharge piping, a unique advantage of this design class. KITOZER matches the hydraulic torque to the motor service factor, so the pump can never overload the motor even when operated out on the curve. The control panel is pre-wired and EMC tested, reducing field commissioning time to one day. The common steel baseplate with grout holes prevents the settling misalignment that plagues field-mounted skids. The bronze impeller and cast iron casing offer decades of corrosion resistance against recycled fire water. The package is delivered with suction strainer, eccentric reducer, concentric increaser, and isolation valves, eliminating miscellaneous procurement for the contractor.
Installation and Maintenance Recommendations
Pour a concrete foundation at least twice the pump weight and twelve meters thick, with anchor bolts set in epoxy grout after rough alignment. Maintain straight suction piping of at least five pipe diameters, eccentric reducer flat on top to eliminate air pockets. The suction lift must stay below the NPSH required by a safety margin of 1 meter. Ventilate the pump room for motor heat dissipation and maintain ambient temperature above 5 degrees Celsius. Conduct weekly automatic no-flow start, monthly test-header flow run, and annual full-flow witness test with the local fire brigade. Inspect the mechanical seal flush line quarterly. Replace lubricating grease in motor bearings every 20,000 hours. Verify relief valve operation annually by slowly closing the discharge valve and observing lift. Keep the test header discharge piped safely to a drainage sump, never to a floor trench. Log every run in the pump logbook, including pressure, duration, and any fault indication.
Price
From 9,800 US dollars per complete pump set including motor, baseplate, valves, gauges, flowmeter, and starter panel. Contact KITOZER for curve confirmation, foam-system compatibility review, and factory lead time.