The KITOZER 18 cubic meter elevated fire water tank is a bolted stainless steel 304 tank installed on a steel or concrete support tower to provide gravity-fed pressurized water for high-rise sprinkler and hydrant systems. The elevated position maintains a minimum 0.10 MPa pressure at the highest sprinkler head without continuous pump operation, which is a core requirement of the Chinese fire code for buildings above 100 meters. The tank is assembled from 1.0 mm pressed stainless steel panels, sealed with food-grade silicone gaskets, and includes a breather valve, level transmitter, and overflow alarm.
The 18 cubic meter effective volume is sized to supply the upper zone hydrant and sprinkler system for at least 10 minutes during a fire, which is the code minimum for roof tanks. Because the water sits above the highest fire pump, it provides pressure even if the main pump and power supply fail entirely. The tank also serves as a daily water reserve for the building domestic system, reducing the duty cycle of the ground-level booster pump. KITOZER delivers the tank in knocked-down panels, so it can be carried by hand up the stairwell to the roof without needing a mobile crane.
Technical Specifications
Nominal volume 18 cubic meters, effective volume 16.2 cubic meters, panel material stainless steel 304 1.0 mm thick, gasket EPDM food grade, bolted connection 304 stainless steel M12, tank dimensions 2.4 m diameter by 4.0 m straight side, design pressure atmospheric, design temperature minus 10 to 60 degrees Celsius, inlet DN50, outlet DN100, overflow DN80, drain DN50, vent DN50 with insect screen, level transmitter 4 to 20 mA, manhole DN500, ladder and safety cage, support structure hot-dip galvanized steel 5 m high.
The pressed panels are 1000 x 1000 mm modular squares, stamped with a 50 mm deep rib pattern that gives each panel stiffness equivalent to a 3 mm flat plate. The panels are bolted through overlapping flanges with 304 stainless steel M12 bolts at 100 mm spacing, and the joint is sealed with a continuous EPDM gasket. The tank bottom is a sloped stainless steel floor draining to a central DN50 drain, so sediment can be flushed without confined-space entry. The support structure is a four-column galvanized steel frame with cross bracing, designed for wind speed 30 m/s and seismic zone 7. The whole assembly, including water, weighs about 20 tonnes, and the roof slab must be checked by a structural engineer before installation.
Application Scenarios
This elevated tank serves as the roof-top fire water reserve in high-rise office towers, hotels, residential buildings above 100 meters, and commercial complexes. It also provides a gravity head for the uppermost sprinkler and hydrant floors that would otherwise require extremely high pump pressure. The tank can be located on the roof mechanical penthouse, on a dedicated steel tower in the landscape area, or integrated into the stairwell core. KITOZER can supply support structure and seismic bracing to meet local wind and earthquake codes.
For buildings above 250 meters, multiple roof tanks may be installed on different mechanical floors, each supplying a pressure zone. The tank also pairs with a small fill pump that draws from the ground-level fire water storage and tops up the roof tank as water is used for domestic purposes. In mixed-use towers, the roof tank may be split into two compartments, one dedicated to fire and one to domestic, with separate level controls. KITOZER offers bolted tanks from 5 cubic meters to 500 cubic meters, all in the same modular panel system, so the same detailing can be reused across a large project.
Key Advantages
Stainless steel 304 panels never need internal repainting, eliminating the recurring maintenance cost of steel tanks in damp roof environments. The bolted design allows panels to be carried by hand up stairwells, which is essential when a mobile crane cannot reach the roof. The tank ships flat packed in cartons, reducing sea freight volume and cost compared with factory-welded tanks. KITOZER also provides a matched fill pump and float valve set that automatically replenishes the tank from the ground-level fire water storage, maintaining a constant reserve.
The stainless steel surface is smooth and non-toxic, so the tank can also supply potable domestic water without a separate liner. The modular panels allow easy future expansion by adding another ring of panels, so a building owner can start with 18 cubic meters and extend to 36 cubic meters if the building usage changes. The bolted joints can be disassembled and reassembled if the tank must be moved, which is useful for temporary projects. KITOZER provides a 10-year warranty on the stainless panels and a 2-year warranty on the fittings, with local technicians available for roof-top inspection visits.
Installation and Maintenance Recommendations
Install the tank on a level concrete or steel platform designed for the full water load plus 25% safety margin, and anchor with hot-dip galvanized bolts. Seal panel joints with silicone on the ground before erection, and torque bolts in a diagonal sequence to avoid uneven stress. Fill the tank slowly over 24 hours to allow panel joints to settle, and check for weeping before adding the full water load. Inspect the level transmitter and float valve quarterly, clean the breather screen annually, and drain and inspect the interior every three years for sediment or biological growth.
Because the tank is on the roof, wind load and seismic load must be checked by a structural engineer, and the support frame must be anchored to the roof slab with chemical anchors. Keep a safety cage on the access ladder, and a lockable hatch on the manhole to prevent unauthorized access. Inspect the galvanized support frame annually for rust at bolted joints, and touch up any exposed steel with zinc-rich paint. In coastal locations, upgrade the tank to stainless steel 316L to resist chloride pitting. KITOZER recommends a 5-year inspection by a NACE inspector, including ultrasonic thickness checks on the bottom panels.
Price
From $4,850 per tank including panels, fittings, and support. Contact +86 13922289957 for elevated tank pricing.