KITOZER
KITOZER

KITOZER Emergency Lighting Central Power Supply: 0.5kVA 90min For Small Sites

KITOZER emergency lighting central power supply model EPS-05 is a centralized battery inverter that powers all emergency lights, exit signs, and evacuation indicators in small commercial buildings, shops, clinics, and office suites. The 0.5 kVA unit charges maintenance-free sealed lead acid batteries during normal grid operation, and automatically switches to inverter output within 0.25 seconds when mains power fails. The unit provides 90 minutes of rated backup illumination per GB 17945 requirements, covering stairwells, corridors, exit doors, and elevator lobbies. The wall-mounted cabinet is compact, with front-access battery compartment and a digital LCD showing battery voltage, load current, and fault status.

Product Overview

The EPS-05 is a pure-sine-wave inverter with built-in battery charger, automatic transfer relay, and monitoring bus. It continuously monitors battery terminal voltage, charger current, inverter output, and every connected emergency circuit. Each output circuit is individually protected by a miniature circuit breaker, and faults are reported via dry contact to the building fire alarm panel. The unit performs an automatic monthly 30-second discharge test and a yearly 30-minute duration test, logging results on the front LCD for maintenance staff. RS485 Modbus allows integration with building management systems for remote status visibility.

Technical Specifications

Rated output 0.5 kVA, pure sine wave. Input voltage 220 volt single phase 50 hertz. Output voltage 220 volt single phase 50 hertz. Transfer time less than 0.25 seconds. Backup duration 90 minutes at rated load. Battery type sealed lead acid, 12 volt 7 Ah, 16 cells. Float voltage 27.6 volt. Boost charge 28.8 volt. Number of output circuits 4, each 6 ampere. Output circuit protection miniature circuit breaker. Ambient temperature 0 to 40 degrees Celsius. Cabinet wall mounted, steel, IP30. LCD display with status, voltage, current, and fault log. RS485 Modbus, dry contact fault output. Certifications CCCF, ISO 9001, GB 17945. Warranty 24 months, battery 3 years.

Application Scenarios

This unit is specified for small office buildings under 5000 square meters, retail shops, clinics, small restaurants, school classrooms, small warehouse corridors, and basement parking under ten thousand square meters. It powers LED emergency lights, illuminated exit signs, and directional indicators along egress paths. The 0.5 kVA rating covers approximately 40 to 60 LED emergency luminaires at 3 to 5 watts each. Facility managers select this model when the site has a single egress core and the local fire authority requires centralized emergency lighting supervision rather than self-contained battery packs.

Advantages and Features

Centralized battery means all emergency lights share a single battery bank, reducing replacement cost compared with self-contained packs. Pure sine wave output drives electronic LED drivers without flicker. The automatic monthly and yearly tests reduce manual inspection labor. Individual circuit protection isolates a single short circuit without disabling the whole system. The front LCD and fault log speed up troubleshooting. Compact wall-mount cabinet fits in small electrical rooms. RS485 integration lets the BMS monitor status remotely.

Installation and Maintenance Recommendations

Install in a ventilated electrical room between 0 and 40 degrees Celsius, away from direct sunlight or heat sources. Wire each emergency circuit on its own protected breaker. Perform annual visual inspection of batteries, terminal torque, and cabinet ventilation. Replace batteries every 3 to 5 years, or when runtime drops below 80 percent of rated. Verify automatic test results on the LCD each month. Clean dust from ventilation slots. Keep spare fuses and a spare battery on site. Log every test result in the emergency lighting logbook.

System Integration

The EPS-05 integrates with the building fire alarm panel through a supervised fault contact that reports mains fail, inverter fail, battery low, ground fault, and output circuit loss. When the fire alarm panel triggers a general emergency signal, the EPS-05 can be commanded to force all emergency circuits on, overriding normal daylight dimming. Each output circuit feeds a dedicated egress zone, so a failed corridor light does not darken the adjacent staircase. The unit communicates via RS485 Modbus to the BMS, allowing facility staff to view per-circuit load, battery state of charge, and the automatic test history from a central workstation. KITOZER pre-programs the test schedule, alert thresholds, and circuit labels at the factory, so commissioning is limited to wiring verification and a single 90-minute discharge witness. The cabinet includes a maintenance bypass switch, so the inverter can be serviced without de-energizing the connected emergency luminaires.

Price

From 680 US dollars per unit including battery set. Contact KITOZER for circuit count customization and factory lead time.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart