KITOZER
KITOZER

KITOZER Emergency Lighting Central Power 1kVA With 36 Circuits

Product Overview

The KITOZER 1kVA emergency lighting central power supply is the heart of a centralized evacuation lighting system for commercial buildings. Instead of each emergency luminaire carrying its own battery, this central unit houses the battery bank and inverter in a single wall-mounted cabinet, feeding multiple lighting circuits through dedicated branch breakers. The controller monitors every circuit for bulb failure, wire break, and short circuit, and reports faults to the fire alarm panel. This architecture reduces battery replacement costs and makes inspection straightforward.

Technical Specifications

Rating: 1kVA / 1kW, single phase 220V output. Input: 220V 50Hz, tolerance 187V to 253V. Output: 36 monitored circuits, each 2A max, total 1kW. Battery: 12V 24Ah VRLA, 16 blocks, standard 90-minute backup at full load. Transfer time less than 0.25 seconds. Charger: 2A intelligent three-stage. Protection: overvoltage, undervoltage, overload, short circuit per circuit, battery reverse, over-temperature. Monitoring: per-circuit current measurement, open-circuit detection, short-circuit detection. Indicators: LCD showing per-circuit status, fault list, battery voltage. Communication: RS485 Modbus, optional Ethernet. Dry contacts: common fault, common running, battery low. Enclosure IP30 wall mount. Compliance GB 17945, CE.

Application Scenarios

The 1kVA central power unit is installed in small to mid-size commercial buildings, office floors, school wings, and retail shops. It feeds evacuation corridor lights, stairwell lights, exit signs, and area emergency lights across up to 36 branch circuits. It is particularly suitable for buildings where local code requires centralized battery backup rather than self-contained luminaires, and where maintenance teams want a single point of inspection rather than walking every floor to test individual batteries.

Advantages and Features

KITOZER central power units automatically run a monthly self-test that briefly switches each circuit to battery, measuring voltage and current to confirm lamp integrity. The LCD lists which circuit has a fault and when it occurred, cutting inspection time from hours to minutes. Batteries are housed in a dedicated drawer with terminal protection. The unit supports both local LCD and remote BMS monitoring. A built-in maintenance bypass allows the inverter to be isolated while lighting continues on utility.

Installation and Maintenance

Mount the cabinet on a structurally sound wall in a ventilated electrical or lighting room. Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life. Wire each lighting circuit through its own 2A breaker and label clearly. Commissioning requires a full discharge test to verify 90-minute backup and a per-circuit lamp test. Maintenance: quarterly visual and terminal check; annual battery conductance test, charger calibration, and per-circuit insulation test; every four years replace batteries.

Price

From $680 per unit with 90-minute battery. Contact +86 13922289957 for multi-circuit options.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top