Table of Contents
ToggleProduct Overview
The KITOZER 1kVA emergency lighting central power supply is the heart of a centralized evacuation lighting system for commercial buildings. Instead of each emergency luminaire carrying its own battery, this central unit houses the battery bank and inverter in a single wall-mounted cabinet, feeding multiple lighting circuits through dedicated branch breakers. The controller monitors every circuit for bulb failure, wire break, and short circuit, and reports faults to the fire alarm panel. This architecture reduces battery replacement costs and makes inspection straightforward, because a single cabinet contains all the batteries and electronics for an entire floor or wing. The unit is designed for 24/7 duty in commercial electrical rooms.
Working Principle
Under normal utility operation, the charger keeps the battery bank float-charged and the inverter continuously produces a regulated 220V AC sine wave that feeds the 36 monitored lighting circuits. Each circuit has a current transducer that measures the lamp load, and the controller compares the measured current to a stored reference. If a lamp burns out or a wire breaks, the measured current drops and the controller flags that circuit as faulty on the LCD. On mains failure, the battery bank immediately supplies the DC bus to the inverter, and lighting continues without interruption. The controller runs a monthly self-test that briefly switches each circuit to battery, measuring voltage and current to confirm lamp integrity.
Technical Specifications
Rating: 1kVA / 1kW, single phase 220V output. Input: 220V 50Hz, tolerance 187V to 253V. Output: 36 monitored circuits, each 2A max, total 1kW. Battery: 12V 24Ah VRLA, 16 blocks, standard 90-minute backup at full load. Transfer time less than 0.25 seconds. Charger: 2A intelligent three-stage. Protection: overvoltage, undervoltage, overload, short circuit per circuit, battery reverse, over-temperature. Monitoring: per-circuit current measurement, open-circuit detection, short-circuit detection. Indicators: LCD showing per-circuit status, fault list, battery voltage. Communication: RS485 Modbus, optional Ethernet. Dry contacts: common fault, common running, battery low. Enclosure IP30 wall mount. Compliance GB 17945, CE.
Application Scenarios
The 1kVA central power unit is installed in small to mid-size commercial buildings, office floors, school wings, and retail shops. It feeds evacuation corridor lights, stairwell lights, exit signs, and area emergency lights across up to 36 branch circuits. It is particularly suitable for buildings where local code requires centralized battery backup rather than self-contained luminaires, and where maintenance teams want a single point of inspection rather than walking every floor to test individual batteries. It is also used in hotel guest floors and hospital corridors where a centralized system simplifies lamp replacement and battery management.
Advantages and Features
KITOZER central power units automatically run a monthly self-test that briefly switches each circuit to battery, measuring voltage and current to confirm lamp integrity. The LCD lists which circuit has a fault and when it occurred, cutting inspection time from hours to minutes. Batteries are housed in a dedicated drawer with terminal protection. The unit supports both local LCD and remote BMS monitoring. A built-in maintenance bypass allows the inverter to be isolated while lighting continues on utility. The cabinet is powder-coated in RAL7035 gray and accepts customer-specified branding.
Options and Accessories
Optional items include an Ethernet communication card for BMS integration, a second 36-circuit expansion board for 72 circuits, a remote annunciator panel for the fire command room, and a 2-hour extended battery cabinet. Custom paint and customer branding are supported. A cloud monitoring gateway pushes battery health and circuit fault status to a web dashboard. Bilingual labels are available at order time.
Installation and Maintenance
Mount the cabinet on a structurally sound wall in a ventilated electrical or lighting room. Keep ambient temperature between 20 and 25 degrees Celsius for maximum battery life. Wire each lighting circuit through its own 2A breaker and label clearly. Commissioning requires a full discharge test to verify 90-minute backup and a per-circuit lamp test. Maintenance: quarterly visual and terminal check; annual battery conductance test, charger calibration, and per-circuit insulation test; every four years replace batteries.
Warranty and Factory Testing
Every KITOZER unit undergoes a full-load burn-in test for 4 hours before shipment, with a printed test report covering input voltage, output voltage, transfer time, and protection relay operation. The power electronics carry a 5-year warranty against manufacturing defects, while the battery bank carries a 3-year replacement warranty. Spare parts are available from stock in Guangzhou, and on-site commissioning support can be arranged for large projects.
Price
From $680 per unit with 90-minute battery. Contact +86 13922289957 for multi-circuit options.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com