KITOZER Emergency Lighting Central Power Supply: 3kVA 180min For Large Buildings

KITOZER emergency lighting central power supply model EPS-30 is a floor-standing three-phase inverter and battery system designed for large commercial buildings, hospitals, hotels, shopping malls, subway stations, and high-rise offices. The 3 kVA unit powers hundreds of emergency luminaires and exit signs along long egress paths, providing 180 minutes of backup illumination per the most stringent local codes. The pure-sine-wave inverter transfers from mains to battery within 0.25 seconds, and the modular battery cabinet allows capacity expansion as the building grows. The front LCD and touch panel display per-circuit status, battery state of charge, and fault history.

Product Overview

The EPS-30 comprises an inverter cabinet, a battery cabinet of sealed lead acid or lithium iron phosphate modules, output distribution with up to 32 individual circuit breakers, and a supervisory controller. The controller performs automatic monthly 30-second tests, quarterly 30-minute tests, and yearly full 180-minute duration tests, logging results for the fire authority. Dry contacts report mains fail, inverter fail, battery low, and ground fault to the building fire alarm. RS485 Modbus and optional SNMP integrate the unit with the BMS. Redundant bypass allows servicing the inverter without de-energizing the emergency circuits.

Technical Specifications

Rated output 3 kVA, pure sine wave. Input voltage 380 volt three phase 50 hertz. Output voltage 220 volt single phase per circuit, 380 volt three phase option. Transfer time less than 0.25 seconds. Backup duration 180 minutes at rated load with standard battery, optional 240 minutes. Battery type sealed lead acid 12 volt 100 Ah, 40 cells, or lithium iron phosphate 48 volt modules. Float voltage 552 volt DC. Number of output circuits up to 32, each 10 ampere. Output circuit protection miniature circuit breaker. Ambient temperature 0 to 40 degrees Celsius. Cabinet floor standing, steel, IP20. LCD touch panel with per-circuit status, battery SOC, fault log. RS485 Modbus, SNMP option, dry contacts. Redundant bypass. Certifications CCCF, ISO 9001, GB 17945. Warranty 24 months, battery 5 years for lithium.

Application Scenarios

This unit is specified for hospitals, hotel towers, shopping malls over 30,000 square meters, subway stations, high-rise offices over 100 meters, airport terminals, and large underground parking. It powers LED emergency luminaires, illuminated exit signs, and directional indicators along long egress paths. The 3 kVA rating covers approximately 300 to 500 LED emergency luminaires at 3 to 5 watts each. Facility managers select this model when the fire authority requires 180-minute duration and per-circuit supervision, and when the building has multiple egress cores.

Advantages and Features

Centralized battery bank reduces replacement cost versus hundreds of self-contained packs. Per-circuit supervision identifies a failed luminaire without manual walk-through. Automatic test schedule reduces inspection labor. Redundant bypass allows servicing without de-energizing emergency circuits. Lithium iron phosphate option doubles battery life and halves cabinet footprint. Pure sine wave output drives electronic LED drivers without flicker. BMS integration gives remote visibility to facility managers.

Installation and Maintenance Recommendations

Install in a ventilated electrical room between 0 and 30 degrees Celsius, since battery life halves for every 10 degrees above 25. Floor load must support the battery cabinet weight, typically 800 to 1200 kilograms. Wire each emergency circuit on its own breaker. Perform annual battery capacity test, terminal torque check, and ventilation inspection. Replace lead acid batteries every 5 years, lithium every 10 years. Verify automatic test results monthly. Keep spare breakers and fuses. Log all tests.

System Integration

The EPS-30 supervisory controller connects to the building fire alarm through supervised dry contacts for mains fail, inverter fail, battery low, ground fault, and per-circuit loss. On fire alarm general signal, the controller forces all emergency circuits to full brightness and disables daylight dimming on connected luminaires. The per-circuit monitoring identifies a failed luminaire or a shorted branch without a manual walk-through, a major labor saving in a large mall or hospital. RS485 Modbus and optional SNMP expose real-time status to the BMS, and an optional web HMI lets facility operators view the 32 circuit loads, battery state of charge, and the automatic test history from any browser. KITOZER pre-programs the zone labels, test schedule, and alert thresholds at the factory, so commissioning reduces to wiring verification and a single 180-minute discharge witness accepted by the fire authority. The redundant bypass path lets facility staff service the inverter or battery cabinet during normal operation without darkening any egress path.

Price

From 4,200 US dollars per unit including standard battery set. Contact KITOZER for circuit count, duration, and battery chemistry options.