The KITOZER emergency release and abort push button station provides two essential controls at the entrance of a gas-protected room: a manual release button to start the discharge countdown, and an abort button to stop the countdown before agent is released. The station is the final human interface between personnel and the suppression system, and its clear labeling and robust construction are critical for safe operation.

Product Overview

The station is housed in a red steel or plastic wall box with two mushroom-head push buttons: one labeled Release with a guard to prevent accidental press, and one labeled Abort. LEDs above each button indicate active countdown or abort state. The station wires directly to the gas release panel. A break-glass or cover option protects the release button from accidental activation.

Technical Specifications

Button types are mushroom-head momentary, red for release and black or yellow for abort. Contact rating is 3 amps at 30 volts DC. Indicators are 24V LEDs. Enclosure is IP30 or IP44. Operating temperature is -10 to 50 degrees Celsius. Terminals accept 1.5 square millimeter wire. Mounting is single or double gang wall box. Dimensions are approximately 180 by 120 by 60 millimeters.

Application Scenarios

Every gas-protected room entrance must have an abort and release station. The station is used by personnel who discover a fire and want to initiate release before the automatic timer, or who need to cancel a false alarm countdown. In industrial settings, the abort button is also used during maintenance to stop a countdown triggered by detector test.

Advantages

Two buttons in one box simplify installation and wall space. The guarded release button prevents accidental discharge. The abort button gives personnel a final chance to cancel. LED indicators show system state at a glance. The station is compatible with all common release panels. Robust construction suits industrial environments.

Installation and Maintenance

Mount the station beside the manual automatic switch at the room entrance, at 1.4 meters height. Route wiring in conduit. Label buttons clearly with permanent legends. Test both buttons quarterly: pressing release starts the panel countdown; pressing abort stops it. Inspect buttons for stiffness or sticking. Replace guards and covers if damaged. Keep legends legible and replace if faded.

Engineering Notes

Mount the abort and release station at the room entrance, alongside the mode switch. Guard the release button to prevent accidental press. Test both buttons quarterly. Label them clearly. Keep the station clean and free of obstruction. Ensure the abort button is large enough to operate quickly.

Code and Compliance

The station must meet local manual call point and release button standards. Verify that pressing release starts the panel countdown and pressing abort stops it. Annual testing includes both buttons. Replace guards and covers if damaged. Keep legends legible.

Warranty and Accessories

From $150 per combined release and abort station. The station carries a two-year warranty. KITOZER supplies single-button and dual-button versions, plus break-glass options. Spare guards and buttons are available. Contact +86 13922289957 for complete entrance station packages.

Detailed Application Examples

The release and abort station at a server room entrance has a guarded red release button and a black abort button. Pressing release starts the 30 second countdown; pressing abort cancels it. LEDs show countdown active. The station is tested quarterly, and the guard is checked for damage.

Long-term Operational Benefits

The release and abort station is a critical safety interface, and its simple mechanical design ensures reliable operation even after years of disuse. The guarded release button prevents accidental discharge, while the prominent abort button gives operators a clear final control. Both buttons are standard industry parts, so replacement is cheap and fast. LED indicators give immediate status without opening the panel.

System Integration

The release and abort station is wired as a supervised circuit so that a broken button contact faults the panel. Pressing release sends a momentary signal that starts the panel countdown; pressing abort sends a separate signal that cancels it. The station LEDs are driven by the panel, so they reflect the actual system state rather than local power. This makes false buttons or cut wires immediately visible during walk tests.

Why Choose KITOZER

KITOZER release and abort stations are built for robust daily use. Each button is contact-tested before shipment. KITOZER supplies matching guards, legends, and back boxes as a complete package, ensuring the entrance station meets code and operates reliably.

Summary

In summary, the release and abort station is the final human interface in a gas suppression system. Its robust design, clear labeling, and supervised wiring ensure that operators can reliably start or cancel a discharge during an emergency. KITOZER supplies the station as a tested, code-compliant component ready for installation at the protected room entrance.

Price

From $150 per combined release and abort station. Contact +86 13922289957 for complete entrance station packages.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart