Table of Contents
ToggleProduct Overview
The KITOZER EMI shielding observation window is a transparent panel built from a multilayer laminated glass with an embedded conductive metal mesh, designed to let operators see inside a shielded enclosure while blocking electromagnetic leakage through the opening. The fine mesh is woven so densely that it remains optically transparent yet electrically continuous, providing high shielding effectiveness across radio and microwave bands. A welded or soldered metal frame bonds the mesh to the surrounding shield, eliminating the leakage path that an ordinary glass window would create.
A shielded room without a viewing window forces personnel to open the door to observe equipment, which breaks the shield every time. The KITOZER window solves that trade-off: it keeps the room sealed while letting operators watch the equipment, read displays, and monitor status without entering. The embedded mesh is bonded at the edges to the metal frame, so the conductive path runs continuously from the glass into the wall shield rather than stopping at the glass edge.
Technical Specifications
Shielding effectiveness greater than 90 dB from 10 MHz to 1 GHz and greater than 60 dB to 10 GHz. Optical transmittance 60 percent to 75 percent depending on mesh density. Mesh aperture below 0.1 mm. Frame made of aluminum or stainless steel with conductive gasket seal. Operating temperature minus 40 to plus 80 degrees Celsius. Custom sizes up to 1500 mm by 2500 mm. Impact resistance per laminated glass standard.
The laminated construction holds the mesh between two glass plies so it cannot scratch, peel, or delaminate with cleaning. The mesh is a woven stainless or copper fabric with aperture small enough to act as a below-cutoff shield at microwave frequencies. The frame is continuously welded to the mesh edge, and a perimeter gasket bonds the frame to the wall. Tinted or low-iron glass options suit rooms with strong daylight.
Applications
Install in shielded control rooms, RF test chambers, medical MRI suite windows, broadcast control rooms, and industrial shielded cabinets where personnel must observe equipment without opening the shield. It is also used on the doors of Faraday cages and on the viewing ports of microwave drying and heating equipment.
An MRI suite uses the window so staff can watch the patient in the scanner room while staying outside the RF shield. A test chamber uses it to watch the device under test through the certification run. A broadcast control room uses it between the studio and the equipment rack. In each case, the window preserves the shield integrity that a transparent acrylic panel would destroy. Architectural projects often specify the window in groups, so that a row of viewing panels gives the control room a clear line into the shielded space without breaking the wall shield. The laminated glass also blocks ultraviolet light, which protects sensitive equipment displays from fading.
Advantages and Features
The laminated construction combines optical clarity with structural safety, and the embedded mesh cannot peel or scratch like a coated film. The welded frame provides a permanent low-resistance bond to the shield wall. Custom sizes and tint options suit architectural integration, and the glass surface cleans like ordinary window glass.
Because the mesh is embedded rather than coated, the window survives years of washing and disinfecting without the shielding layer wearing off. The laminated safety glass also meets glazing codes for human occupied rooms, and the frame can be finished to match the interior architecture. Because the mesh is embedded, the window can be cleaned with the same routine as ordinary glazing, and it will not yellow or haze over years of exposure. The panel is also available in heated versions for cold room installations where condensation would otherwise cloud the view.
Installation and Maintenance
Set the window into the wall opening and seal the perimeter with a continuous EMI gasket, bonding the frame to the shield on all four sides. Avoid drilling near the mesh edge. Clean the glass with standard non-abrasive cleaners; do not use sharp scrapers that could damage the mesh. Inspect the frame bond annually for corrosion.
During install, verify the gasket is continuous at the corners and that the frame is bonded to the wall shield on every side. A single unbonded corner leaks enough to degrade the room certification. In medical or cleanroom settings, the glass wipes down with the same disinfectant as the rest of the room. When specifying a window, balance the mesh density against the lighting: a denser mesh gives more shielding but lower transmittance, so a room with weak daylight should pair the window with internal lighting rather than choosing the coarsest mesh. The frame finish can match the wall or be specified as a contrasting trim for visual wayfinding.
Price
From $180 per square meter. Contact plus 86 13922289957 for custom size quote. Frame and gasket package available.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com