The KITOZER microgrid control system is a dedicated version of the KITOZER EMS built for off-grid and weak-grid installations. It coordinates PV, wind, battery, diesel generators, and controllable loads so that critical services stay online even when the main grid is absent or unstable. The controller can switch seamlessly between grid-connected and islanded mode, and can prioritize loads by criticality so that essential processes continue while non-essential loads shed first.
Table of Contents
ToggleProduct Overview
The microgrid controller runs on a redundant pair of industrial gateways, each with independent power supplies and network links. One gateway is the active master and the other is the hot standby, taking over in under 50 milliseconds if the primary fails. The software layer includes a dropping control module that shares active and reactive power among multiple PCS, a diesel dispatch module that decides when to start the generator based on battery state of charge and load forecast, and a load-shedding module with up to 16 priority groups. A local HMI touchscreen gives operators a one-page view of frequency, voltage, power flow, and generator status, while the cloud portal provides remote access for service teams.
Technical Specifications
Redundant controllers, 2x quad-core, 8GB RAM, 128GB SSD. Protocols: Modbus TCP, IEC 61850, DNP3, CAN, SunSpec. Load shedding groups: up to 16, with user-defined priority. Generator dispatch: start, stop, and set-point control over analog or digital signals. Islanding transition time less than 20 milliseconds. Frequency and voltage droop configurable. Data logging 1-second resolution, 12 months on board. Operating temperature minus 25 to plus 60 degrees Celsius. Power supply 9 to 36V DC, redundant. KITOZER three-year warranty, optional five-year extended support.
Application Scenarios
This microgrid controller is used at remote telecom base stations, mining camps, island resorts, and agricultural pumping stations where the grid is unreliable or non-existent. It is also specified for military forward operating bases and disaster-recovery campuses that must ride through extended outages. In campus settings, the controller ties rooftop PV, a 500kWh battery block, and a 500kVA diesel into a single stable bus, allowing the facility to sell surplus PV back to the grid when utility power returns.
Key Advantages
Redundant controllers remove the single point of failure that plagues many microgrid projects, and the hot standby takes over so quickly that connected loads do not notice the switch. Native generator dispatch avoids the need for a separate PLC that integrators would otherwise have to program. Load shedding by priority lets operators define which circuits are truly critical, avoiding the blanket outages that happen when a single breaker trips. The controller also logs every islanding event, which is valuable for performance reporting and for optimizing the diesel runtime budget.
Installation and Maintenance
Install both controllers in the same cabinet but on separate power supplies and separate network switches. Wire the generator start, stop, and emergency-stop signals through hardwired interlocks in addition to the communication commands, so the microgrid can still control the generator if the network drops. Commissioning requires a site visit from a KITOZER engineer to tune the droop settings and load-shed thresholds. Annual maintenance includes verifying the transfer time between controllers, backing up the configuration, and updating the firmware to the latest stable release. Keep a spare controller on site for remote locations where shipping delays would otherwise cause extended outages.
Price
From $9,800 per microgrid controller pair. Contact KITOZER for turnkey microgrid designs including PV, battery, and generator sizing.