Table of Contents
ToggleProduct Overview
The KITOZER 10kW three-phase EPS emergency power unit bridges the gap between small single-phase lighting backup and larger three-phase motor emergency power. It is engineered to carry mixed critical loads including three-phase smoke exhaust fans, fire pump control circuits, pressurization fans, and emergency lighting distribution boards simultaneously during mains failure. The DSP-controlled inverter delivers balanced three-phase output with independent per-phase voltage regulation, ensuring that uneven single-phase loads distributed across the three phases do not cause unbalance faults. The wall or floor cabinet is designed for mounting in electrical rooms of mid-size commercial and industrial buildings.
Working Principle
The online double-conversion topology keeps the inverter continuously active. The front-end rectifier draws three-phase utility power, produces a regulated DC bus, and charges the battery bank. The inverter then reconstructs a pure three-phase sine wave from the DC bus, conditioning both voltage and frequency before it reaches the load. If utility voltage collapses or the phase rotation is lost, the battery bank feeds the DC bus through a diode OR-ing arrangement, and the inverter output continues without interruption. The controller monitors each phase independently and alarms if unbalance exceeds a preset threshold. A maintenance bypass allows the inverter to be isolated while the load is fed directly from utility.
Technical Specifications
Rating: 10kVA / 10kW, three phase four wire 380V / 220V. Input: 380V three phase, 50Hz, tolerance 323V to 456V. Output: pure sine wave, THD less than 3 percent, voltage balance less than 1 percent between phases, frequency 50Hz plus or minus 0.5Hz on battery. Transfer time less than 0.25 seconds. Battery: 12V 100Ah VRLA, 40 blocks total arranged in two strings, standard 90-minute backup at rated load, extendable. Charger current 20A with temperature compensation. Protection includes DC overcurrent, AC overvoltage, overload with inverse time curve, short circuit, and fan failure monitoring. Communication: RS485 Modbus standard, optional Ethernet SNMP, 8 dry-contact inputs and 8 relay outputs. LCD HMI with event history of 500 records. Enclosure IP20, cold-rolled steel, floor standing with lifting eyes. Compliance GB 17945, CE.
Application Scenarios
This 10kW EPS is widely installed in mid-size shopping malls, underground rail transit station ancillary rooms, hotel basement levels, hospital clinical buildings, and factory workshop fire protection systems. It commonly powers smoke extraction fans, positive pressure supply fans in stairwells, fire damper actuators, fire elevator auxiliary circuits, and centralized emergency lighting distribution boxes. It can also serve as backup for fire pump control panel logic supplies where the pump motor itself is driven by a dedicated diesel engine or larger UPS-EPS hybrid. Property developers value it because a single cabinet covers both lighting and small fan loads without requiring a separate UPS and generator. The unit also serves as the alternate power source for fire telephone exchanges and fire shutter controls in basement levels where a generator is impractical due to noise and exhaust constraints.
Advantages and Features
KITOZER 10kW EPS uses a three-phase insulated gate bipolar transistor inverter with independent per-phase control, allowing single-phase emergency lighting loads to share the same cabinet as three-phase fan motors without de-rating. The battery management system monitors individual block voltage, internal resistance, and surface temperature, and reports degraded blocks before they cause a discharge failure. An internal maintenance bypass allows the inverter to be isolated for service while the load continues on utility. The unit supports both automatic weekly self-test and manual full-duration discharge test. The HMI supports multiple languages and exports event logs to USB.
Options and Accessories
Optional items include an SNMP card for building management integration, a parallel redundancy kit for 1+1 operation, a galvanic isolation transformer, and an IP54 enclosure for dusty environments. Extended runtime cabinets can be added in the field. A cloud monitoring gateway pushes battery state of health to a web dashboard. Remote annunciator panels with mimic diagrams are available for fire command rooms. Custom paint, customer logos, and bilingual labels are supported at order time.
Installation and Maintenance
Locate the EPS in a dedicated electrical or fire equipment room with ambient temperature between 20 and 25 degrees Celsius for maximum battery life. Provide a separate upstream utility feeder and a separate emergency distribution board. Size the output cable per local code and keep voltage drop under 3 percent. Commissioning must include a 30 percent and 100 percent discharge test, and a transfer test under live load. Maintenance: quarterly visual and terminal check; annual battery impedance, charger calibration, and fan replacement inspection; every three years replace capacitors and inspect contactors. Keep spare fuses and a spare fan on site.
Warranty and Factory Testing
Every KITOZER unit undergoes a full-load burn-in test for 4 hours before shipment, with a printed test report covering input voltage, output voltage, transfer time, and protection relay operation. The power electronics carry a 5-year warranty against manufacturing defects, while the battery bank carries a 3-year replacement warranty. Spare parts are available from stock in Guangzhou, and on-site commissioning support can be arranged for large projects.
Price
From $2,680 per unit with 90-minute battery bank. Custom backup duration and communication options quoted to order. Contact +86 13922289957 for project quotation.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com