Product Overview

The KITOZER 15kW three-phase EPS emergency power supply is engineered for buildings that require extended-duration fire-fighting backup beyond the standard 90-minute code minimum. With a standard two-hour battery bank at rated load, this unit keeps emergency lighting, smoke control fans, fire pump control circuits, and evacuation signaling energized through prolonged outages such as natural disasters, grid maintenance, or fire-fighting operations that exceed a few hours. The online double-conversion topology ensures that the load never sees a transfer transient, and the modular battery cabinet allows future runtime extension without replacing the inverter.

Technical Specifications

Rating: 15kVA / 15kW, three phase four wire 380V / 220V. Input: 380V three phase plus neutral, 50Hz, tolerance minus 15 percent to plus 20 percent. Power factor on input greater than 0.95 with active power factor correction. Output: pure sine wave, THD less than 3 percent, static voltage regulation plus or minus 1 percent, transient recovery within 20 milliseconds for 0 to 100 percent load step. Battery: 12V 120Ah VRLA blocks, 60 blocks in two parallel strings, nominal 120 minutes at full load. Charger: 40A intelligent charger with temperature sensor. Protection: DC bus overvoltage, battery low voltage alarm and trip, output overload at 125 percent for 10 minutes, short circuit, internal over-temperature. Communication: Modbus RTU and TCP, 8 dry contacts, SNMP option. Enclosure: IP20 floor standing, two-section cabinet with separate battery compartment. Compliance GB 17945, CE, ISO 9001.

Application Scenarios

The 15kW two-hour EPS is specified for high-rise office towers, underground transit stations, large shopping mall basements, hospital ICU buildings, and industrial plants where fire departments require prolonged evacuation support. Typical load list includes stairwell pressurization fans, basement smoke extraction fans, fire pump control and monitoring circuits, emergency lighting inverters, fire telephone exchanges, and electric fire shutter control panels. It is also suitable for data center ancillary loads that must survive extended utility outages without starting a generator.

Advantages and Features

The KITOZER 15kW EPS separates the power electronics section from the battery section, reducing heat buildup around battery blocks and extending service life. The battery management system provides per-string current monitoring and diode isolation so a shorted block in one string does not drag down the other. An integrated maintenance bypass with mechanical interlock allows safe inverter servicing. The HMI supports multiple languages and exports event logs to USB for third-party code audit. Units can be paralleled for redundancy or future capacity growth.

Installation and Maintenance

Install in a dedicated fire equipment room with controlled temperature between 20 and 25 degrees Celsius, relative humidity below 85 percent, and no corrosive gas. Floor loading must support the cabinet weight, which can exceed 900 kilograms with a full two-hour battery bank. Provide a dedicated ventilation path for battery off-gassing. Commissioning must include a full-rate discharge test to verify the two-hour runtime, and a transfer test at 50 percent and 100 percent load. Maintenance: quarterly terminal torque and visual inspection; annual battery conductance test, charger calibration, and contactor inspection; every five years replace DC bus capacitors and fans.

Price

From $4,280 per unit with standard 120-minute battery bank. Contact +86 13922289957 for extended runtime options and project discounts.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com