ToggleProduct Overview
The KITOZER 20kW three-phase EPS emergency power supply is sized to handle the inrush current of direct-on-line started fire pump motors while simultaneously carrying emergency lighting and control loads. Motor-starting duty is the key challenge for fire-rated EPS: standard UPS units trip on 6 times rated motor inrush, but this EPS is over-sized on inverter and transformer to deliver 300 percent overload for one minute, allowing a 7.5kW or 11kW fire pump to start directly without a soft starter. The unit is packaged as a floor-standing fire cabinet suitable for pump rooms and basement electrical rooms.
Technical Specifications
Rating: 20kVA / 20kW continuous, three phase four wire 380V / 220V. Overload capacity: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent motor inrush for 10 seconds. Input: 380V three phase, PFC greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 100Ah VRLA, 60 blocks, standard 90-minute backup at 20kW, extendable. Charger 40A. Protection: output short circuit with electronic trip, reverse battery polarity, fan failure, DC bus soft start. Communication: Modbus TCP, SNMP, 8 dry-contact I/O. Display: 7-inch color HMI with mimic diagram. Enclosure IP21 floor standing, powder coated. Compliance GB 17945, GB 51348, CE.
Application Scenarios
This EPS is typically specified for mid-size commercial and industrial buildings where the fire pump motor must be backed up. Loads include a 7.5kW or 11kW fire pump motor direct-on-line starter, sprinkler pump control panel, hydrant pump control panel, smoke exhaust fans, pressurization fans, and a building-wide emergency lighting bus. It is also used in parking garages, warehouse distribution centers, and mid-rise hotels where a generator is not installed but fire code requires an alternate power source for the pump and egress systems.
Advantages and Features
The KITOZER 20kW EPS includes a built-in motor-starting profile that boosts inverter voltage for 10 seconds during pump start, preventing the output from sagging under locked-rotor current. The cabinet integrates a main breaker, maintenance bypass, and output distribution sub-breakers for each emergency circuit, reducing field wiring. Battery strings are individually fused and monitored. The HMI displays a one-line diagram with live status of each pump command and feedback contact, giving fire officers a clear view of system readiness.
Installation and Maintenance
Install in a clean, ventilated pump room or electrical room. Ensure the floor can support the cabinet and battery weight, typically 1,100 kilograms. Route battery cables with appropriate cross-section to keep voltage drop below 1 percent during pump start. Commissioning requires a live motor-start test with the actual pump load to confirm inverter voltage sag and duration. Maintenance: quarterly visual, terminal torque, and pump-start test; annual battery conductance and inverter calibration; every five years replace fans and DC capacitors. Keep a logged discharge test every 12 months for fire department audit.
Price
From $5,680 per unit with 90-minute battery and motor-start capability. Contact +86 13922289957 for pump-motor-specific sizing.