KITOZER EPS Emergency Power Supply 50kW Central Fire Power

Product Overview

The KITOZER 50kW three-phase EPS is a central emergency power unit for very large buildings and campus-level fire systems. It feeds multiple emergency distribution boards across a facility, backing up fire pumps, smoke control fans, pressurization fans, central emergency lighting, fire elevators, and fire command center equipment. The unit uses a modular inverter design where two 25kW power modules operate in parallel, allowing hot-swap replacement of a faulty module without shutting down the load. This architecture dramatically improves availability for mission-critical fire systems, and the controller balances load share between modules within 5 percent.

Working Principle

Each 25kW inverter module has its own front-end rectifier and shares a common DC bus fed by the battery bank. The two modules synchronize their output frequency and phase through a dedicated parallel communication link, and share load current within 5 percent. If one module faults, the other immediately assumes the full load without interruption, and the controller raises a redundancy alarm. The battery bank floats on the common DC bus at all times. On mains failure, the rectifiers stop and the battery supplies the bus. The HMI displays per-module load share, per-string current, and per-block voltage on a single screen.

Technical Specifications

Rating: 50kVA / 50kW continuous, three phase four wire 380V / 220V. Configuration: two 25kW modular inverters in parallel, N+1 redundancy optional. Overload: 125 percent for 10 minutes, 150 percent for 1 minute, 300 percent inrush for 10 seconds. Input: 380V three phase, PFC greater than 0.95, THDi less than 5 percent. Output: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 1 percent, frequency 50Hz plus or minus 0.5Hz. Battery: 12V 100Ah VRLA, 180 blocks in three strings, standard 90-minute backup. Charger: 100A with temperature compensation. Protection: DC overcurrent, insulation monitoring, AC overvoltage, overload, short circuit, battery low, over-temperature, fan failure. Communication: Modbus TCP, SNMP, Web HMI, 32 dry-contact I/O. Display: 10-inch color HMI. Enclosure IP21 floor standing, three-section cabinet. Compliance GB 17945, CE.

Application Scenarios

The 50kW EPS is specified for airport terminals, railway stations, convention centers, large hospital complexes, university campuses, and high-rise super-tall towers. It typically powers a zone-based emergency distribution network with separate boards for basement pumps, tower-top fans, stairwell pressurization, and command-center loads. It can start two 22kW fire pumps sequentially and carry 20kW of continuous lighting and control load. It is also used as the alternate supply for critical safety systems in semiconductor fabs and pharmaceutical cleanrooms, where even a few milliseconds of outage could ruin a production batch.

Advantages and Features

The modular inverter design means a faulty 25kW module can be pulled out and replaced while the unit continues to carry the load on the remaining module. Battery strings are independently fused and monitored, and weak strings can be isolated without full shutdown. The HMI provides a one-line diagram with per-module load share, per-string current, and per-block voltage trends. Remote monitoring over Ethernet integrates with the building management system and fire alarm panel, giving operators a single view of emergency power readiness. The unit supports scheduled automatic discharge tests with auto-recharge and PDF report export. The HMI also supports a dark mode for 24/7 fire command room viewing, and the unit can be locally disabled for safe servicing without tripping upstream breakers.

Options and Accessories

Options include a third 25kW module for true N+1 redundancy, a parallel synchronization kit for up to 4 units, a galvanic isolation transformer, and an IP54 enclosure. A remote mimic panel for the fire command room is available. Extended runtime cabinets for 2 or 4 hours can be added later. A cloud monitoring gateway pushes battery health and module status to a web dashboard. Spare inverter modules can be stocked on site for hot-swap. Custom paint and customer branding are supported.

Installation and Maintenance

Coordinate the cabinet footprint with the electrical room layout: the three-section cabinet is about 1,800mm wide, 800mm deep, and 2,000mm tall, with a 90-minute battery bank weighing about 3,600 kilograms. Use lifting eyes for positioning. Run battery cables in dedicated tray and size them per local code. Commissioning requires a full load bank test, per-module load share verification, and a pump-start demonstration. Maintenance: quarterly visual and terminal check; annual battery conductance, contactor inspection, and fan filter replacement; every five years replace DC capacitors and contactor arc chutes.

Warranty and Factory Testing

Every KITOZER unit undergoes a full-load burn-in test for 4 hours before shipment, with a printed test report covering input voltage, output voltage, transfer time, and protection relay operation. The power electronics carry a 5-year warranty against manufacturing defects, while the battery bank carries a 3-year replacement warranty. Spare parts are available from stock in Guangzhou, and on-site commissioning support can be arranged for large projects.

Price

From $14,800 per unit with 90-minute battery and modular inverters. Contact +86 13922289957 for N+1 redundancy pricing.