Product Overview

The KITOZER 5kW single-phase EPS emergency power supply is a dedicated fire-fighting emergency power unit designed to provide reliable backup electricity for evacuation lighting, fire pumps, smoke exhaust fans, and other critical safety loads during a mains outage. Built around a high-frequency DSP-controlled inverter and a sealed maintenance-free battery bank, the unit delivers pure sinusoidal output with zero transfer interruption between utility and battery modes. The compact wall-mount or floor-standing cabinet suits commercial buildings, shopping malls, hospitals, schools, and office towers where space is limited but code-compliant emergency backup is mandatory.

Technical Specifications

Rating: 5kVA / 5kW, single phase 220V output. Input: 220V AC nominal, 50Hz, wide voltage tolerance from 187V to 253V. Output waveform: pure sine wave, THD less than 3 percent, voltage regulation plus or minus 2 percent, frequency 50Hz plus or minus 0.5Hz on battery. Transfer time: less than 0.25 seconds, typically zero-break for electronic loads. Battery: 12V 100Ah sealed lead-acid valve-regulated modules, 20 blocks in series, standard 90-minute backup at full load, extendable to 120, 180, or 240 minutes. Charger: intelligent three-stage charging, 10A max, temperature compensated. Protection: overvoltage, undervoltage, overload, short circuit, battery reverse polarity, and over-temperature. Communication: standard RS485 Modbus, optional dry-contact alarm and SNMP card. Display: LCD showing input voltage, output voltage, battery voltage, load percentage, fault code, and runtime. Enclosure: IP20 cold-rolled steel cabinet, wall-mount bracket included. Compliance: GB 17945, CE, ISO 9001.

Application Scenarios

The 5kW EPS is typically deployed in mid-rise commercial buildings serving evacuation corridor lighting, emergency exit signs, smoke control pressurization fans, fire shutter controls, and small fire pump junction boxes. It is also commonly used in underground parking garages where lighting must remain energized during evacuation, in hospital operating anterooms that cannot tolerate sudden loss of power, and in school and campus gymnasium evacuation routes. Because the unit is single-phase, it pairs naturally with 220V emergency lighting loops and small fan coils rather than three-phase motor loads.

Advantages and Features

KITOZER EPS units ship with built-in battery test scheduling, periodic automatic self-discharge checks, and event logging for code audits. The inverter topology is online double-conversion, meaning the load always sees conditioned sine wave power whether mains is present or not. Front-access battery drawers simplify replacement without disconnecting output wiring. The cabinet is powder-coated in standard RAL7035 gray and accepts customer-specified branding. A 5-year warranty covers the inverter module and charger, while batteries carry a 3-year replacement warranty.

Installation and Maintenance

Mount the unit in a well-ventilated, dust-free room above flood level, leave 500mm clearance on all sides for airflow. Connect the utility feed through a dedicated upstream breaker sized at 1.5 times rated input current, and route the emergency output through a separate distribution panel clearly labeled. Commissioning requires a full discharge test to confirm backup time matches design. Quarterly maintenance should include visual inspection of battery terminals, torque check, fan filter cleaning, and a manual transfer test. Annual maintenance should include internal dust extraction, battery impedance test, and calibration of voltage sensing.

Price

From $1,480 per unit including standard 90-minute battery. Extended backup and communication options quoted on request. Contact +86 13922289957 for factory lead time and project pricing.