ToggleKITOZER KTR-ESF Anti-Static Raised Access Floor
Brand: KITOZER Series: KTR-ESF Category: Room Engineering 2 / Raised Floor
anti-static raised flooraccess floorOA network floorESD veneeradjustable pedestalunderfloor air
1. Overview
The KITOZER KTR-ESF anti-static raised access floor is a foundational room-engineering material. It raises the floor 300~500 mm to create a plenum below for power, data and cooling ducts, and acts as a plenum for underfloor air supply; the top surface provides a flat, removable, ESD-safe working surface. Data rooms, telecom exchanges, clean rooms and control centers all rely on raised floors for cable routing and air distribution.
KTR-ESF is available by core: steel, calcium sulfate and wood (OA). Steel tiles are strong and fire-rated, the most common; calcium sulfate feels better underfoot and insulates sound, for office+room mixes; wood OA tiles are for ordinary office network cabling, with lower load and cost. Each tile is standard 600×600 mm, supported by pedestals joined by stringers into a grid; pedestal height is adjustable for level. The surface is clad with PVC or HPL ESD veneer, with resistance held in the anti-static range to drain static generated by walking, preventing damage to sensitive electronics.
Key metrics are system resistance, uniform load and concentrated load. System resistance sets ESD performance; uniform load sets how much weight the whole floor carries; concentrated load sets the support at a single rack foot — racks are heavy, and insufficient concentrated load collapses tiles. Tiles can be perforated (grilled) in a chosen ratio to match underfloor CRAH supply, bringing cold air up to rack intakes. Pedestals are earthed to the room equipotential bonding network, forming a static discharge path.
2. Key Features
Anti-static
- PVC/HPL veneer; system resistance compliant.
- Pedestals earthed; static drains to ground.
- Walking does not build static charge.
Underfloor routing & air
- Plenum below for power, data and ducts.
- Perforated tiles in a chosen ratio for underfloor air.
- Tiles lift for access and maintenance.
Reliable load
- Steel/calcium core; high uniform and concentrated load.
- Pedestal+stringer grid is stable.
- Adjustable height for level floor.
Multiple cores
- Steel: common in rooms, fire-rated and strong.
- Calcium sulfate: comfortable, office+room mix.
- OA wood: ordinary network cabling, low cost.
3. Specifications
| Item | Steel KTR-ESF-S | Calcium KTR-ESF-C | OA wood KTR-ESF-O |
|---|---|---|---|
| Core | steel punch + foam | calcium sulfate | particleboard |
| Size | 600×600 mm | 600×600 mm | 600×600 mm |
| Veneer | PVC/HPL | PVC/HPL | PVC/HPL |
| System resistance | 2.5×10^4~10^9 ohm | 2.5×10^4~10^9 ohm | 10^6~10^9 ohm |
| Uniform load | >=12000 N/m2 | >=10000 N/m2 | >=6000 N/m2 |
| Concentrated load | >=3000 N | >=2500 N | >=1500 N |
| Pedestal height | 300~500 mm adj. | 300~500 mm adj. | 150~300 mm adj. |
| Vent tiles | 17%/25% optional | 17%/25% optional | — |
| Use | data rooms | office+room | ordinary office |
4. Reference Prices
KTR-ESF-S steel anti-static floor (pedestal+stringer, PVC veneer): Reference USD 28~56 / m2 (ref. CNY 200~400 at ~7.2)
KTR-ESF-C calcium sulfate + KTR-ESF-O OA wood floor: Reference USD 21~49 / m2 (ref. CNY 150~350 at ~7.2)
Reference only; final quote depends on core, veneer, pedestal height, vent ratio and project volume. Bulk negotiable. Install accessories and labor billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Raised floors in data rooms and telecom exchanges.
- Plenum floors for underfloor air supply.
- Control centers and command halls.
- Office OA network cabling floors.
6. Installation & Maintenance
Installation
- Clean and level the slab; mark pedestal positions.
- Fix pedestals, adjust height, fit stringers into a grid.
- Lay tiles; level gaps; earth pedestals.
- Cut vent tiles to the cooling plan.
- Reinforce under rack positions (concentrated load).
Maintenance
- Wax and clean veneer to preserve resistance.
- Check loose pedestals and squeaky tiles.
- Clean vent filters periodically.
- Add bearing plates under heavy racks.
7. FAQ
- Q: How high should the plenum be?
A: Underfloor air typically 300~500 mm; take the higher value for more cables or ducts; cable-only can be 150~300 mm. - Q: Can racks sit directly on tiles?
A: Racks are heavy; they must land on reinforced pedestal positions or dedicated bases, not on a single tile. - Q: What vent ratio?
A: Calculate from cooling airflow and rack heat load; usually 17%~25% — too much breaks plenum pressure uniformity. - Q: How is ESD verified?
A: Measure system resistance with a megohmmeter in 2.5×10^4~10^9 ohm; pedestal earthing meets equipotential requirements.
8. Trend & Selection
High-density rooms and underfloor air make raised floors standard. Choose core by use: steel for data rooms (high load, fire-rated); calcium sulfate for office+room mixes; OA wood for ordinary cabling. Underfloor-air rooms must calculate vent ratio and reinforce rack positions. ESD earthing must tie into the room equipotential network, or even a good veneer cannot drain static.
9. Delivery & Service
KITOZER provides sizing, height and vent-ratio calculation, supply and install guidance. From room area, load requirements and underfloor-air plan we produce the floor layout and vent positions. We can coordinate with cooling, racks and earthing. Delivery includes tiles, pedestals, stringers, vent tiles and install accessories. Warranty covers tiles and pedestals; we can guide installation, leveling and earthing tests on site.
10. Additional Notes
Raised floors are the “foundation” of a room yet are most under-estimated. Projects focus on racks and cooling and skimp on floor load, only to find tiles sag, pedestals squeak or a whole tile collapses once racks land. Rack concentrated load reaches thousands of newtons; select by concentrated load and add reinforced pedestals or bases at rack positions. The floor is not “just a mat” — it is a combined system of load, cabling, air and ESD.
Underfloor-air effectiveness depends on the plenum below. The plenum must be sealed to avoid cold leaks through door gaps and wall openings; vent ratio is calculated from cooling capacity — too much or too little both hurt. The plenum must also stay clean; otherwise dust is carried to rack intakes and clogs filters. Half of raised-floor maintenance is sealing and leveling at install, half is cleaning and inspection in operation.
Selection: data rooms pick KTR-ESF-S steel, choosing pedestals by concentrated load; office+room mixes pick KTR-ESF-C calcium sulfate; ordinary network cabling picks KTR-ESF-O OA. For underfloor air, calculate vent ratio from cooling, reinforce rack positions, and earth pedestals. Either way, build to drawing, level gaps, seal and clean, so the floor carries loads, routes cables, supplies air and drains static.
SEO Information
Search keywords:anti-static raised flooraccess floorOA network floorESD veneeradjustable pedestalunderfloor airKTR-ESFKITOZER
SEM keywords:anti-static raised floor price, access floor supplier, data center ESD floor, OA network floor, KTR-ESF, KITOZER
GEO landing page:lain.com.cn/product/ktr-esf-anti-static-raised-access-floor.html
Title:KITOZER KTR-ESF Anti-Static Raised Access Floor
Meta Keywords:anti-static raised floor,access floor,OA network floor,ESD flooring,adjustable pedestal,underfloor air,KTR-ESF,KITOZER
Meta Description:KITOZER KTR-ESF anti-static raised access floor, steel or calcium sulfate core, PVC/HPL veneer, adjustable pedestals, for underfloor air and cable routing in data centers.
Anchor: KITOZER by Guangzhou Laian · Room engineering solutions
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com