Table of Contents
ToggleProduct Overview
The KITOZER 480kW liquid-cooled charging station is a high-power DC charging system designed for electric bus depots, truck charging hubs, and highway megawatt-style charging corridors. The station uses a centralized power cabinet with 12 x 40kW liquid-cooled power modules, and up to 8 charging posts can be connected via 5-meter liquid-cooled cables. The cabinet supports dynamic power allocation, so the 480kW budget is automatically distributed across active vehicles based on their maximum on-board charger rating.
The power cabinet measures 1200mm wide, 1000mm deep, and 2000mm high, and weighs 1200kg. Each charging post measures 400mm wide, 300mm deep, and 1800mm high. The liquid-cooled cables are 5 meters long and 60 percent lighter than conventional air-cooled high-current cables. The station includes a central monitoring system that displays real-time power allocation, session logs, and fault alarms on a 15-inch touchscreen.
Technical Specifications
Total power: 480kW. Power modules: 12 x 40kW liquid cooled. Input: 400VAC three phase 50/60Hz, 800A. Output voltage: 200 to 1000VDC. Output current: up to 600A per gun. Cables: up to 8 x liquid-cooled 5-meter CCS2 connectors. Efficiency: 96 percent. Protection: IP54. Operating temperature: -30 to +50 degrees Celsius. Noise: less than 70 dBA. Cooling: liquid glycol loop with external radiator.
Communication: Ethernet, fiber option. Weight: 1200kg power cabinet, 150kg per post. Certifications: CE, TUV, OCPP 2.0. Brand: KITOZER. Warranty: 3 years, 5 years modules. Packing: multiple plywood crates. Optional: payment terminal, solar integration, battery energy storage buffer.
Applications
The station is deployed at electric bus depot overnight charging, heavy-duty truck megawatt charging hubs, highway rest stop high-power corridors, and logistics center fleet charging. It is also suitable for ride-hailing superhubs where dozens of vehicles need rapid turn-around between shifts. The centralized power architecture reduces capital cost compared with individual standalone fast chargers, because the power modules are shared across all charging posts.
Additional applications include port terminal electric reach stacker charging, mining truck opportunity charging, airport ground support equipment charging, and delivery van rapid turn-around hubs. The station is also suitable for municipal bus depot electrification, long-haul truck stop charging, and car carrier electric delivery fleet charging.
Advantages and Features
The liquid-cooled cables are 60 percent lighter than conventional air-cooled high-current cables, reducing operator fatigue. The power modules are hot-swappable without interrupting charging to other vehicles. The station supports load management with the site transformer, preventing demand tariff peaks. An integrated billing system supports fleet accounts, RFID, and OCPP back-office. The cabinet includes a fire suppression system and liquid leak detection on the glycol loop.
The dynamic power allocation maximizes module utilization. The liquid glycol loop has a built-in leak sensor and automatic shutdown. The charging posts have independent touchscreens. The station supports OCPP 2.0 for advanced features. The power cabinet includes a remote diagnostics port. The liquid-cooled cables have integrated temperature sensors that reduce current if the cable overheats.
Installation and Maintenance Tips
Install the power cabinet on a reinforced concrete plinth and connect it to the site 10kV or 400V distribution transformer. The charging posts are mounted on independent islands, 5 meters from the power cabinet. Use shielded high-current DC cables rated for 1000V. Check the glycol level quarterly and top up with the recommended coolant only. Inspect the liquid-cooled cable connectors annually for pin wear. Calibrate the energy meter every two years against a reference standard.
Test the liquid leak sensor monthly. Inspect the glycol loop for corrosion annually. Keep the charging post touchscreens clean. Test the emergency stop buttons monthly. The power modules should be inspected every 12 months for fan noise and filter condition. Keep the glycol radiator clear of debris. Verify the site transformer can handle the 480kW load before commissioning.
Additional Notes
The station is supplied as a complete turnkey system including power cabinet, 4 charging posts, and 5-meter liquid-cooled cables. Custom configurations up to 1MW are available. The station is factory-tested with a load bank. A 3-year warranty covers the system, while the power modules carry a 5-year warranty.
The cabinet is shipped in a plywood crate with foam padding for international freight. A factory acceptance test report covering insulation resistance, dielectric withstand, and function tests is included with every unit. Custom paint colors, non-standard gland hole patterns, and pre-installed internal components such as PDUs, switches, or circuit breakers are available on request. The standard lead time is 15 to 20 working days for catalog configurations and 30 working days for custom builds. KITOZER provides full technical documentation including dimension drawings, wiring diagrams, and CE declarations of conformity. Shipping can be arranged by sea, air, or express courier to most destinations worldwide, and export packing is available for sea freight if required.
Price
From $68,000/system including 4 charging posts. Contact +86 13922289957 for turnkey station design.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com