KITOZER fan wall system replaces one or two large centrifugal computer room air handlers with an array of smaller plug fans mounted in a single wall across the hot aisle return. Each fan is independent, N plus N redundant, and controlled by a shared controller that modulates speed based on static pressure. If one fan fails, the remaining fans ramp up automatically to maintain airflow, so cooling continues without interruption. The 100 kW model described here is built for medium data halls with 60 to 120 racks, and it delivers total airflow of around 35,000 CFM against up to 150 Pa external static pressure.
Table of Contents
ToggleProduct Overview
A fan wall is a row of plug fans mounted in a prefabricated steel wall section, typically located at the end of a hot aisle or in the return path of a data hall. Each fan is a backward curved impeller with an EC motor, rated for continuous duty. The array is fed hot aisle exhaust air, which passes through a chilled water coil or a DX coil located behind the fan wall, and the cooled air is discharged into the room. Because each fan is independent, the wall can be sized to match the load exactly, and fans can be added later as the hall fills. The controller reads static pressure in the aisle and modulates every fan in parallel, keeping the pressure setpoint regardless of how many fans are running.
Technical Specifications
Total airflow: 35,000 CFM (16,500 L/s) at 100 Pa. Number of fans: 10 x 3.0 kW EC plug fans, N plus 1 redundancy. Motor type: EC permanent magnet, IP54, class F insulation. Fan impeller: 450 mm backward curved, galvanized steel. Wall dimensions: 3600 mm wide x 3000 mm high x 600 mm deep. Construction: 1.5 mm galvanized steel casing, RAL 7035 powder coat. Coil: optional 6 row chilled water coil, 100 kW at 7/12 C entering air 35 C. Filters: G4 + F7 bag filters on the return side. Controller: standalone PLC with 7 inch HMI, Modbus TCP, 0-10 V fan speed control. Power supply: 400 V three phase 50 Hz. Noise level: 72 dB(A) at 1 meter, attenuated by 15 dB across the hall. Operating temperature 10 to 45 degrees Celsius.
Applications
Fan walls are chosen when traditional CRAH units run out of floor space, when floor loading is constrained, or when N plus N redundancy is required without duplicating entire air handlers. They are deployed in hyperscale data halls, colocation expansions, retrofits that add cooling without raising floor load, and modular data centers where the fan wall forms the end wall of the container. They pair with chilled water plants, dry coolers, and free cooling coils. Typical customers include colocation operators that scale cooling rack by rack, enterprise data centers that want granular redundancy, and GPU AI clusters that need high airflow against variable static pressure.
Advantages and Features
The biggest advantage is redundancy. A single CRAH failure takes 100 percent of its airflow offline, but a single fan wall failure removes only 10 percent of the array, and the rest compensate. Second, fan walls use EC motors that are 15 to 20 percent more efficient than belt driven centrifugal fans at part load. Third, because the fans are distributed across a wall, airflow to the room is uniform and there are no hot zones near a single large unit. Fourth, the wall takes no floor space inside the white space, freeing floor for racks. Fifth, fans can be serviced one at a time without turning off the whole array, because each fan has an isolation shutter. Sixth, the controller integrates with BMS and DCIM platforms for remote monitoring and alarm.
Installation and Maintenance
The fan wall arrives as a preassembled wall section on a flatbed truck. A crane or forklift places it on a prepared plinth, and water, power, and control cables are connected. Commissioning takes one day: the engineer sets static pressure setpoint, tunes fan speed curves, and tests failover by stopping one fan and verifying the rest ramp up. Maintenance is quarterly: inspect filter differential pressure, replace filters when DP gauge reaches 250 Pa, and listen for abnormal fan noise. Annually, check fan mounting bolts, impeller balance, and motor bearing temperature. Each fan slides out on rails for service without removing the wall panel. Spare fans are kept on site for swap-out in under 30 minutes.
Warranty and Support
KITOZER warrants the fan wall array for 5 years on the casing and controller, and 2 years on each EC fan. Factory engineers commission the array and hand over a full set of as-built drawings, fan performance curves, and BMS point lists. Each fan has a 30 year design life under continuous duty, and spare fans are kept on site as part of the recommended spare parts package. Remote monitoring via Modbus TCP allows the service team to spot trending issues before they become alarms, and the controller logs every fan speed, alarm, and failure event for post-incident review.
Price
From $28,500 per 100 kW fan wall array, including 10 EC fans, controller, filters, and casing. Coil and controls quoted separately. Contact +86 13922289957 for factory pricing.