KITOZER
KITOZER

KITOZER FFU Fan Filter Unit 1000 CFM HEPA H14 Ceiling Mount

Product Overview

The KITOZER FFU (Fan Filter Unit) 1000 CFM HEPA H14 is a ceiling-mounted air purification module that combines an EC centrifugal fan, a H14 HEPA filter, and a control module in a single 1175x575mm or 1175x1175mm housing. FFUs are the standard air supply device in clean rooms, semiconductor fabrication areas, pharmaceutical filling lines, hospital operating rooms, and microscopy laboratories. Each FFU draws ceiling plenum air, passes it through the HEPA filter, and delivers laminar downward flow at the work zone. The 1000 CFM model covers approximately 4 to 6 square meters of clean room ceiling at ISO 5 to ISO 6 cleanliness. KITOZER FFUs feature EC motors for energy efficiency, stepless speed control, and daisy-chain BMS integration.

Technical Specifications

Housing: 1175x1175mm, 1.0mm galvanized steel, powder coat white. Fan: EC centrifugal backward-curved impeller, 230V AC, 0.55 kW. Airflow: 0 to 1000 CFM adjustable. External static pressure: 250 Pa max. Filter: H14 HEPA, 99.995 percent MPPS, initial resistance 220 Pa. Noise: 52 dBA at 1 meter. Control: stepless 0 to 10V or PWM, RS485 Modbus, daisy chain up to 32 units. Motor protection: IP54, thermal overload. Operating temp: 10 to 40 degrees Celsius. Weight: 35 kg. Mount: ceiling grid T-bar. CE, EN 1822, RoHS. KITOZER brand, 5 year motor warranty, 1 year filter warranty.

Applications

The 1000 CFM H14 FFU is used in ISO 5 and ISO 6 clean rooms, semiconductor wafer probe and assembly areas, pharmaceutical sterile filling lines, injectable manufacturing, hospital operating rooms and ICU laminar ceilings, biological safety cabinet supply, microscopy and nanotechnology labs, and electronics clean assembly. It is also used in data center high-density hot spot cooling as overhead fan modules with MERV filters instead of HEPA. The daisy-chain control allows a central BMS to adjust fan speed based on particle counts or occupancy.

Key Advantages

First, EC motor efficiency: 60 percent lower energy than AC motors at part load. Second, H14 filtration: meets the strictest clean room standards. Third, laminar airflow design: uniform velocity 0.35 to 0.45 m/s at work zone. Fourth, modular layout: add or remove FFUs as clean room layout changes. Fifth, low noise: suitable for operating rooms and labs. Sixth, easy filter replacement from below without tools. Seventh, BMS integration for energy recovery during unoccupied periods.

Installation and Maintenance

FFUs are lowered into the ceiling T-bar grid, wired in a daisy chain, and balanced during commissioning with an anemometer at work zone. Initial filter resistance should be recorded; when resistance doubles or reaches 450 Pa, replace the HEPA filter. Pre-filters (G4 or F8) should be installed upstream and replaced every 6 months to extend HEPA life. KITOZER provides a filter change schedule and supplies genuine H14 replacement filters. Motor bearings are sealed and rated for 50,000 hours.

Price

From $1,850 per FFU including H14 HEPA filter. Contact +86 13922289957 for clean room project pricing with multi-unit discounts.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Scroll to Top