The KITOZER 24-core rack-mount fiber termination box is a 1U slide-out enclosure that combines splicing, storage, and patching in one compact unit for enterprise server rooms and small telecom POPs. Unlike a simple patch panel, this box includes internal splicing trays and ample slack storage, so installers can terminate both incoming backbone cable and horizontal distribution cables in the same chassis. The front panel accepts 24 SC simplex or 12 LC duplex adapters, and the slide-out body rolls forward on steel rails to expose the splicing area without disturbing front patch cords.
Table of Contents
ToggleTechnical Specifications
Mechanical: 1U, 19-inch rack, depth 240 mm, cold-rolled steel 1.2 mm, black powder coat, weight 4.5 kg. Capacity: 24 fibers, 2 x 12-core sliding splicing trays, front panel 24 SC or 12 LC duplex. Optical: insertion loss less than 0.3 dB, return loss greater than 50 dB UPC / 60 dB APC, compatible OS2 and OM3. Cable entry: rear gland plate, side entry option, cable tie points, M5 ground. Environmental: operating -10 C to +60 C, humidity 95 percent. Features: slide-out chassis on rails, removable adapter frame, slack storage area, label holders. Compliance: CE, RoHS, KITOZER, 5 year warranty.
Applications
This 1U rack-mount termination box is used as the floor distributor in enterprise structured cabling, sitting between building backbone switches and horizontal patch cords to wall outlets. It suits small data rooms, branch office telecom closets, and university departmental equipment racks where rack space is limited but splice storage is required. CCTV headend rooms, broadcast studios, and factory automation control cabinets also use it to consolidate fiber runs from distributed cameras, sensors, and remote I/O blocks. It is a practical choice for contractors who want to avoid mixing wall-mount boxes and rack ODFs in the same installation.
Key Advantages
The slide-out rails allow technicians to access splices while front patch cords remain connected, which is a major safety benefit on live networks. The dual splicing trays handle both incoming feeder and outgoing distribution cables in one box, reducing the number of enclosures on the wall. Removable adapter frames support SC, LC, ST, and FC field termination without chassis replacement. The integrated slack storage loop absorbs extra fiber length required for future re-routing. Steel construction with powder coat finish protects against incidental impact in busy equipment rooms. The box shares the same mounting footprint as the rest of the KITOZER ODF family, so spare chassis can be stocked as common inventory.
Installation and Maintenance
Mount the box in a 19-inch rack using M6 cage nuts and screws. Pull the chassis forward on its rails to access the rear entry area. Route backbone cable through the rear gland, secure the outer jacket, and leave a 1 m service loop inside the box. Strip and clean the buffer tubes, lay fibers into the splicing trays, and fusion-splice to pigtails. Seat splice sleeves in the tray channels and close the tray lids. Route pigtails to the rear of the adapter frame, install the chosen adapters, and push the chassis back into the rack. Patch to active equipment on the front. Clean connectors with a one-click cleaner before insertion, and inspect end faces once per quarter. Re-tie cable bundles annually and update labels when circuits change.
Price
From $135/pc. Contact +86 13922289957 for rack mount termination box quote.