Table of Contents
ToggleKITOZER KTR-FA Fire Alarm Sounder & Strobe
Brand: KITOZER Series: KTR-FA Category: Data Center Engineering 2 / Fire Alarm
sounder strobefire alarmstrobe lightDC24V alarmKTR-FA
1. Overview
KITOZER KTR-FA is the “last mile” of a fire alarm system. Smoke and heat detectors detect a fire, signal the fire alarm control panel (FACP), which then triggers the sounder-strobe — a sharp alarm tone plus high-frequency red flash, so anyone in corridors, rooms and electrical rooms immediately knows “fire, evacuate.” Detectors are the eyes; the sounder-strobe is the voice and visible alert.
KTR-FA is a palm-sized square/round device in fire-standard red, with a red strobe on top (LED or rotating lamp) and a piezoelectric buzzer or motorized siren inside. Powered by DC24V (fire system standard), driven directly by the FACP output module. Sound pressure ≥100dB at 3m; strobe 1–2Hz, red visible in any light.
Sounder-strobes are non-addressable (wired to a FACP output, sounds on power) or addressable (with a code, individually testable at the panel). Rooms usually use non-addressable (cheap, simple); large systems use addressable (locates which unit sounded). Mount on corridor walls, exits and electrical-room entrances at 2.2–2.5m high, where sound carries far.
2. Key Features
Acoustic
- ≥100dB at 3m.
- Multiple tones (fire/emergency/pulse).
- Piezo buzzer or motorized siren.
Optical
- Red strobe, LED or rotating.
- 1–2Hz; visible ≥15m.
- Red housing (fire standard).
Electrical & wiring
- DC24V fire-system standard.
- Non-addressable: 2-wire, sounds on power.
- Addressable: with code, individually testable.
Structure & mount
- Plastic/metal housing, wall mount.
- 2.2–2.5m above floor.
- Dust cover on select models.
3. Specifications
| Item | KTR-FA-ST | KTR-FA-AD | KTR-FA-WP |
|---|---|---|---|
| Type | Non-addressable | Addressable | Weatherproof |
| Sound | ≥100dB | ≥105dB | ≥100dB |
| Strobe | LED red | LED red | Rotating red |
| Power | DC24V | DC24V | DC24V |
| Wiring | 2-wire | Bus+address | 2-wire |
| Ingress | IP30 | IP30 | IP54 |
| Mount | Wall 2.2m | Wall 2.2m | Wall 2.2m |
4. Reference Prices
KTR-FA-ST non-addressable (DC24V, 100dB, LED strobe, wall): Reference USD 11~21 / unit (ref. CNY 80~150 at ~7.2)
KTR-FA-AD/WP addressable/weatherproof (105dB, coded or IP54): Reference USD 21~42 / unit (ref. CNY 150~300 at ~7.2)
Reference only; final quote depends on addressability, ingress rating and brand. Floor/building bulk orders discounted. Requires a fire alarm control panel. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center corridors and room entrances.
- Electrical rooms, UPS and battery rooms.
- Office corridors and stairwells.
- Basement garages and warehouses.
- Outdoor shelters: use IP54 weatherproof.
6. Installation & Maintenance
Installation
- Locate per drawings: corridors, exits, important room entrances.
- Fix wall base with anchors or 86 box.
- Wire: DC24V (+/-) to FACP output module.
- Addressable: set code by DIP or electronic.
- Clip on housing; confirm strobe and tone.
- Commission: FACP manual trigger test.
Maintenance
- Monthly fire test: verify linked sounder-strobe.
- If strobe fails, check LED or rotating lamp.
- If tone is hoarse, check buzzer/siren.
- Retighten terminals.
- Keep housing clean and unobstructed.
7. FAQ
- Q: Sounder-strobe vs smoke detector?
A: Different. Smoke detector is a sensor (finds smoke); sounder-strobe is the alert (sounds for people). System: detector → FACP → sounder-strobe. Both are needed. - Q: Is a sounder-strobe mandatory in rooms?
A: Per code, rooms staffed by people and electrical rooms must have it. Unattended small cabinet closets can cover it from the corridor. - Q: How loud?
A: Ordinary spaces ≥100dB at 3m; noisy plant rooms (AC, generator) choose ≥105dB. Avoid oversized units right where people stand. - Q: What if DC24V fails?
A: The fire system runs on standby batteries (8+ hours). The sounder-strobe has no internal battery — it relies on system power.
8. Trend & Selection
Sounder-strobes evolve from “single-tone siren” to “multi-tone + voice”: newer models play voice messages (“Fire, please evacuate via the nearest exit”), friendlier for foreigners and visitors. Trends: addressing (each unit has a location), LED (replacing rotating lamps, longer life) and low power. Selection: confirm system type — simple non-addressable uses ST, addressable systems use AD; outdoor/damp choose IP54; sound level by ambient noise (100dB normal, 105dB noisy); mount unobstructed ≥2.2m; test with smoke/heat/gas-suppression linkage.
9. Delivery & Service
KITOZER provides selection: based on system type (non/addressable), environment (indoor/outdoor) and sound level, we configure the model. Bundled with FACP, smoke/heat detectors and gas suppression. Delivery includes unit, base and manual. Buzzer, LED and housing faults replaced free in warranty.
10. Additional Notes
The most common pitfall is mounting too low or behind obstructions. Code calls for 2.2–2.5m; below 1.5m the sound is blocked by racks and door frames. Mount above exits and room entrances so the red flash is in view.
Another pitfall is “smoke detectors only, no sounder.” Some small projects skip the sounder to save cost — the FACP shows an alarm but nobody on site knows, letting a small fire grow. A sounder costs tens to hundreds of CNY, but it is the step that “reaches people” and cannot be omitted.
Also: no linkage test. If installed but untested, a loose wire or unprogrammed output means silence in a real fire. During monthly drills, manually trigger the sounder-strobe to confirm it really sounds and flashes.
Selection summary: non-addressable ST, addressable AD, outdoor IP54; sound level by environment; mount high and visible; test monthly. The sounder-strobe is what “wakes people” in a fire — one second earlier hearing and seeing is one more second to evacuate.
SEO Information
Search keywords:fire alarm sounderstrobe alarmsounder strobeDC24V fire alarmfire alarm deviceKTR-FAKITOZER
SEM keywords:fire alarm sounder price,sounder strobe supplier,DC24V fire alarm,data center fire alarm,KTR-FA,KITOZER
GEO landing page:lain.com.cn/product/ktr-fa-fire-alarm-sounder-strobe.html
Title:KITOZER KTR-FA Fire Alarm Sounder & Strobe
Meta Keywords:fire alarm sounder,strobe alarm,sounder strobe,DC24V fire alarm,data center fire alarm,KTR-FA,KITOZER
Meta Description:KITOZER KTR-FA fire alarm sounder and strobe, DC24V, ≥100dB, red strobe, linked to fire alarm control panel, for data center, electrical room and corridor.
Anchor: KITOZER by Guangzhou Laian · Environmental monitoring systems
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com