Table of Contents
ToggleProduct Overview
The KITOZER 500GPM @ 80m electric centrifugal fire pump is a UL/CCC certified main fire water pump designed to deliver reliable pressurized water for sprinkler, hydrant, and spray systems in commercial buildings, industrial plants, warehouses, and high-rise structures. The pump adopts a horizontal end-suction centrifugal structure with a closed impeller dynamically balanced at grade G6.3, ensuring smooth operation, low vibration, and long mechanical seal life. A dedicated fire-duty motor with Class F insulation and service factor 1.15 provides the sustained overload margin required by NFPA 20 and GB 6245 standards. The complete skid includes the pump, motor, base frame, suction and discharge pressure gauges, relief valve, drain valve, and flexible couplings, ready for piping connection on site.
Technical Specifications
Rated flow 500 US gallons per minute (about 113 cubic meters per hour), rated head 80 meters, motor power 45 kW, rated speed 2950 rpm, three phase 380V/50Hz, suction flange DN150, discharge flange DN125, maximum working pressure 1.6 MPa, NPSH required 4.5 meters, efficiency 78%, impeller material cast iron HT250 with optional bronze wear ring, shaft material 42CrMo with stainless steel sleeve, mechanical seal tungsten carbide to silicon carbide, base frame welded steel with anti-vibration mounting pads. Certified to CCCF, GB 6245, ISO 9001, with optional UL and FM approval. Enclosure IP55, insulation Class F, duty S1 continuous.
Application Scenarios
This pump is suitable as the main fire water supply pump for shopping malls, office towers, hospital buildings, underground parking garages, logistics warehouses, food processing plants, automotive manufacturing workshops, and petrochemical storage areas with ordinary hazard classifications. It can be paired with a jockey pump to maintain static pressure in the ring main and a diesel engine pump as the standby driver where grid reliability is insufficient. Typical installations include basement pump rooms in high-rise buildings above 100 meters, independent fire pump houses in industrial parks, and dedicated fire pump skids for data center cooling water backup loops.
Key Advantages
The KITOZER fire pump delivers high efficiency across a wide curve, so the operating point remains stable even when multiple sprinklers open sequentially. The back pull-out design allows impeller and seal removal without disturbing piping alignment, drastically reducing maintenance time. Canned mechanical seals eliminate leakage risks associated with packing glands, and the integrated pressure gauge manifold gives operators instant visual confirmation of suction and discharge conditions. KITOZER also offers a matched fire pump controller with auto-start, phase-failure protection, and remote RS485 monitoring, creating a complete pump room solution that reduces engineering interface risks for the contractor.
Installation and Maintenance Recommendations
Install the pump on a reinforced concrete foundation of at least 1.5 times the pump skid weight, with spring isolators rated for 75% isolation efficiency. Keep suction piping eccentric reducer horizontal to avoid air pockets, and size the suction line velocity below 2.5 meters per second. Prime the pump before first start and verify rotation direction. Run a weekly 5-minute no-load test and a monthly full-flow test per NFPA 25. Inspect the mechanical seal every six months, lubricate bearings annually, and record current, pressure, and vibration readings for the pump room log. Keep the pump room temperature above 5 degrees Celsius and below 40 degrees Celsius, with adequate ventilation.
Price
From $2,680 per set including pump, motor, base frame, and gauges. Contact +86 13922289957 for factory quotation and lead time.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com