KITOZER
KITOZER

KITOZER Fire Pump Controller: 90kW Automatic Inspection Cabinet

Product Overview

The KITOZER 90 kW fire pump inspection controller is a wall or floor-mounted electrical cabinet that starts, stops, protects, and automatically tests electric fire pumps in accordance with GB 50974 and NFPA 20 requirements. The cabinet includes a main circuit breaker, motor starter, contactor, bypass circuit, PLC controller, HMI touchscreen, and a built-in periodic patrol test function that runs the pump at low speed every week for a few minutes to detect mechanical seizure without discharging large water volumes. The controller communicates via RS485 Modbus to the building fire alarm panel.

The patrol test function is mandatory by Chinese fire code for pumps above 15 kW, because long idle periods cause pump shaft seizure, bearing corrosion, and seal hardening. Without a weekly test, a fire pump that has sat idle for 6 months may fail to start when needed. The KITOZER controller runs the pump at reduced speed via star-delta or soft starter, circulating water through a bypass loop rather than discharging to the sprinkler system. This exercises the motor, shaft, and seals while keeping water use to a minimum. The HMI displays the test results, including current, pressure, and any faults.

Technical Specifications

Rated power 90 kW, rated current 160 A, three phase 380V 50Hz, incoming breaker MCCB 250A, main contactor 225A, alternative star delta soft starter, control voltage 24V DC, HMI 7 inch color touchscreen, PLC Siemens or equivalent, patrol test frequency weekly, test duration 5 to 15 minutes adjustable, protection functions overcurrent, phase loss, phase sequence, overload, under voltage, dry run, output dry contacts 8, RS485 Modbus RTU, enclosure IP54 floor standing, CCCF certified, GB 50974 compliant. Dimensions 800 x 600 x 2000 mm.

The cabinet is fabricated from 2.0 mm cold rolled steel, powder coated RAL7035 grey, with a front door that locks with a key. The main circuit breaker is a 250A MCCB with shunt trip, the main contactor is a 225A AC3 rated unit, and the soft starter or star-delta contactors are sized for 160A. The PLC is a Siemens S7-200 SMART or equivalent, with a 7 inch HMI mounted on the door. The patrol test logic starts the pump at low speed for 5 minutes, monitors current and pressure, and logs the result. Eight dry contact outputs report run, stop, fault, and alarm states to the fire alarm panel. RS485 Modbus RTU allows remote monitoring on the building BMS.

Application Scenarios

This controller pairs with electric fire pumps from 30 kW to 132 kW in commercial buildings, industrial plants, data centers, warehouses, and high-rise towers. The automatic patrol test is mandatory by Chinese fire code for pumps above 15 kW, because long idle periods cause pump shaft seizure and bearing corrosion. Typical installations include basement pump rooms with duty and standby pump pairs, where the controller alternates duty weekly and switches to backup on any fault. KITOZER offers matching controllers for jockey pumps and diesel engine pumps to complete the pump room electrical package.

For high-rise towers, two controllers side by side manage duty and standby pumps, with an interlock that prevents both starting at once. For data centers, the controller reports pump status to the DCIM platform via Modbus TCP. For industrial plants, the controller is integrated into the central building management system. KITOZER also offers a diesel engine controller with similar features, managing engine start, fuel level, and coolant temperature. The controllers can be ordered as a pair with a shared duty alternation module.

Key Advantages

The weekly patrol test exercises the pump at low speed through a reduced voltage circuit, detecting mechanical problems weeks before a real fire would expose them. The HMI displays real-time current, voltage, pressure, and event history in Chinese and English, simplifying operator training. The cabinet includes a manual bypass switch so the pump can be run directly during controller maintenance. KITOZER pre-wires and pre-tests the cabinet at the factory, so on-site commissioning requires only power and motor connection, typically completed in one day.

The CCCF certification means the cabinet is accepted by Chinese fire authorities without additional testing. The HMI event log stores 1000 events with timestamp, so maintenance staff can review pump history. The soft starter reduces mechanical stress on the pump shaft during start, extending pump life. The cabinet is IP54, suitable for damp pump rooms. KITOZER provides a 2-year warranty on the controller and a 1-year warranty on the HMI. Spare PLC and contactors are kept in stock in Guangzhou for next-day dispatch.

Installation and Maintenance Recommendations

Install the controller in a clean, dry pump room with ambient temperature between 0 and 40 degrees Celsius, and allow 500 mm clearance on all sides for wiring and ventilation. Size the incoming cable according to the pump full load current plus 25% margin, and run a separate earth bond to the pump frame. Verify phase sequence before first start, and confirm the pressure switch setpoints match the pump cut-in and cut-out. Inspect the cabinet quarterly for dust, tighten power terminals annually, and keep a log of patrol test results. Replace the HMI battery every 5 years to preserve the PLC program.

Because the controller contains 160A power components, keep the cabinet door closed and locked when not in use, to prevent accidental contact. Test the manual start and stop buttons monthly, and verify the fault alarm contacts by simulating an overload. Keep a spare fuse set and a spare control relay on site. The patrol test schedule should be set for a low-occupancy hour, such as Sunday 2 AM, so any noise does not disturb building occupants. KITOZER recommends a 5-year overhaul that includes replacing contactor contacts and inspecting the PLC battery.

Price

From $1,980 per cabinet. Contact +86 13922289957 for pump controller pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart