KITOZER
KITOZER

KITOZER Fire Pump Controller: 90kW Automatic Inspection Cabinet

Product Overview

The KITOZER 90 kW fire pump inspection controller is a wall or floor-mounted electrical cabinet that starts, stops, protects, and automatically tests electric fire pumps in accordance with GB 50974 and NFPA 20 requirements. The cabinet includes a main circuit breaker, motor starter, contactor, bypass circuit, PLC controller, HMI touchscreen, and a built-in periodic patrol test function that runs the pump at low speed every week for a few minutes to detect mechanical seizure without discharging large water volumes. The controller communicates via RS485 Modbus to the building fire alarm panel.

Technical Specifications

Rated power 90 kW, rated current 160 A, three phase 380V 50Hz, incoming breaker MCCB 250A, main contactor 225A, alternative star delta soft starter, control voltage 24V DC, HMI 7 inch color touchscreen, PLC Siemens or equivalent, patrol test frequency weekly, test duration 5 to 15 minutes adjustable, protection functions overcurrent, phase loss, phase sequence, overload, under voltage, dry run, output dry contacts 8, RS485 Modbus RTU, enclosure IP54 floor standing, CCCF certified, GB 50974 compliant. Dimensions 800 x 600 x 2000 mm.

Application Scenarios

This controller pairs with electric fire pumps from 30 kW to 132 kW in commercial buildings, industrial plants, data centers, warehouses, and high-rise towers. The automatic patrol test is mandatory by Chinese fire code for pumps above 15 kW, because long idle periods cause pump shaft seizure and bearing corrosion. Typical installations include basement pump rooms with duty and standby pump pairs, where the controller alternates duty weekly and switches to backup on any fault. KITOZER offers matching controllers for jockey pumps and diesel engine pumps to complete the pump room electrical package.

Key Advantages

The weekly patrol test exercises the pump at low speed through a reduced voltage circuit, detecting mechanical problems weeks before a real fire would expose them. The HMI displays real-time current, voltage, pressure, and event history in Chinese and English, simplifying operator training. The cabinet includes a manual bypass switch so the pump can be run directly during controller maintenance. KITOZER pre-wires and pre-tests the cabinet at the factory, so on-site commissioning requires only power and motor connection, typically completed in one day.

Installation and Maintenance Recommendations

Install the controller in a clean, dry pump room with ambient temperature between 0 and 40 degrees Celsius, and allow 500 mm clearance on all sides for wiring and ventilation. Size the incoming cable according to the pump full load current plus 25% margin, and run a separate earth bond to the pump frame. Verify phase sequence before first start, and confirm the pressure switch setpoints match the pump cut-in and cut-out. Inspect the cabinet quarterly for dust, tighten power terminals annually, and keep a log of patrol test results. Replace the HMI battery every 5 years to preserve the PLC program.

Price

From $1,980 per cabinet. Contact +86 13922289957 for pump controller pricing.

Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com

Shopping Cart